    User name adev

    Log entry time 04:27:56 on March 12, 2001

    Entry number 58515

    keyword=End_of_Run_2826
    ****************************
     Run Number: 2826
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=coin10,mode=coincidence,Lmom=1.1130,Rmom=-2.799,Ene=3.399,Angle_R=18.582,Angle_L=53.172
    
    Time of run = 12.542594 min
    Av. current (on 3x) = 14.781099 uA
    Av. current (on 1x) = 14.729675 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   11.0849  |   11.1236  |   11.1450
    up-down    (mC)|   -0.0283  |   -0.0299  |   -0.0002
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 11484.582 Hz  |    776977.5 /mC  |   57.423 Hz  |   8642787  |   200   |    779690.1 /mC
        2      | 13626.988 Hz  |    921919.8 /mC  |    6.813 Hz  |  10255067  |  2000   |    925138.4 /mC
        3      | 2219.4544 Hz  |    150154.9 /mC  |   73.982 Hz  |   1670263  |    30   |    150679.1 /mC
        4      | 6442.1667 Hz  |    435838.1 /mC  |    6.442 Hz  |   4848089  |  1000   |    437359.7 /mC
        5      | 1366.562 Hz  |     92453.3 /mC  | 1366.562 Hz  |   1028414  |     1   |     92776.1 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1356.378 Hz  |     91764.4 /mC  | 1356.378 Hz  | 1020750.0  |     1   |     92084.7 /mC
        8    | 1024.0 Hz  |     69277.7 /mC  |    0.016 Hz  |    770617  | 65535   |     69519.5 /mC
        output                      1142.912 Hz
    Av. deadtime from accepted triggers = 0.2166
    Av. deadtime from gated scalers = 0.2159
    Accepted triggers  = 860105.00000
    Rate of Left Arm Pulser for electronic DT  = 10.183964
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.181307
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00026096033
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 13735.072
    Rate of Right Arm Strobe  = 27059.763
        Signal     |    Charge   (C)   
       upstream    |    0.0110708     
       upstream 3x |    0.0111087     
       upstream 10x|    0.0111449     
      downstream   |    0.0110991   
     downstream 3x |    0.0111386   
     downstream 10x|    0.0111451    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2826 at Mon Mar 12 02:57:04 EST 2001
    Right Arm D1 momentum                    : 2.799
    Right Arm arm angle                      : 18.5811
    Left Arm D1 momentum                      : 1.11301
    Left Arm arm angle                        : 53.172
    Tiefenbach Hall A energy                : 3399.16
    Right Arm arm mispointing (HPT)          : -1.61288
    Left Arm arm mispointing (HPT)            : 5.41063
    Right Arm Q1 power supply current        : 2104.55
    Right Arm Q1 momentum                    : 2.7988
    Right Arm Q1 gauss meter                 : -0.0523
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1204.48
    Right Arm Q2 momentum                    : 2.79874
    Right Arm Q2 gauss meter                 : 0.6324
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 997.409
    Right Arm D1 momentum                    : 2.799
    Right Arm D1 NMR                         : 1.03868
    Right Arm Q3 power supply current        : 1113.56
    Right Arm Q3 momentum                    : 2.79899
    Right Arm Q3 gauss meter                 : 0.4995
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 837.165
    Left Arm Q1 momentum                      : 1.11276
    Left Arm Q1 gauss meter                   : 0.07159
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 479.237
    Left Arm Q2 momentum                      : 1.11295
    Left Arm Q2 gauss meter                   : -0.2529
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 371.548
    Left Arm D1 momentum                      : 1.11301
    Left Arm D1 NMR                           : 0.412048
    Left Arm Q3 power supply current          : 443.16
    Left Arm Q3 momentum                      : 1.11313
    Left Arm Q3 gauss meter                   : 0.2213
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 14.7381
    Current on Unser monitor                : 20.0016
    Current on Upstream bcm                 : 14.7451
    Current on Downstream bcm               : 14.731
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 14.959
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.16
    Tiefenbach Hall C energy                : 884.441
    Delta(E)/E width (MV_AI_DXWID)          : 1.1861
    IPM1C12.XPOS                            : -0.00698324
    IPM1H04A.XPOS                           : -0.128627
    IPM1H04A.YPOS                           : 0.460792
    IPM1H04B.XPOS                           : 0.00923297
    IPM1H04B.YPOS                           : -0.0380123
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616895
     HacR_HPM_LVDT:VALr                     : -1047
     HacR_VPM_LVDT:VALr                     : 143
     HacR_HPE1313A:0_Ch58                   : -0.522949
     HacR_HPE1313A:0_Ch55                   : 22.8027
     HacR_HPE1313A:0_Ch54                   : -0.826172
     HacR_alignROLL                         : -0.344718
     HacR_alignPITCH                        : -0.0316749
     HacR_alignHPT                          : -1.61291
     HacL_HPM_LVDT:VALr                     : -8180
     HacL_VPM_LVDT:VALr                     : -548
     HacL_HPE1313A:0_Ch58                   : -0.293457
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.387207
     HacL_alignROLL                         : -0.0126852
     HacL_alignPITCH                        : 0.0176007
     HacL_alignHPT                          : 5.41305
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 70
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 19.5
    haH2_P_Exhaust_R                         : 19.96
    haH2_P_Fill_Bottle_R                     : 20.05
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -680
    haD2_P_Exhaust_R                         : 17.99
    haD2_P_Fill_Bottle_R                     : 37.21
    haD2_DP_Fill_Exhaust_R                   : 0.0744
    haSC200_6_Sensor_1_R                     : 241.31
    haSC200_6_Sensor_2_R                     : 27.29
    haSC200_6_Sensor_3_R                     : 38.09
    haSC200_6_Sensor_4_R                     : 40.73
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.74
    haITC502_1_Sensor_2_R                    : 83.03
    haITC502_1_Sensor_3_R                    : 77.22
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.01
    haITC502_4_Sensor_1_R                    : 84.8
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 90.99
    haITC502_5_Sensor_2_R                    : 82.04
    haITC502_5_Sensor_3_R                    : 266.9
    haITC502_6_Sensor_1_R                    : 98.54
    haITC502_6_Sensor_2_R                    : 82.45
    haITC502_6_Sensor_3_R                    : 28.32
    Right Arm Arm Collimator                 : 0.615186
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 202
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON