    User name adev

    Log entry time 11:04:36 on March 12, 2001

    Entry number 58541

    keyword=End_of_Run_2843
    ****************************
     Run Number: 2843
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=out,comment=coin22,mode=coincidence,Lmom=2.4660,Rmom=-1.6138,Ene=3.399,Angle_R=45.240,Angle_L=27.649
    
    
    Time of run = 19.30734 min
    Av. current (on 3x) = 28.909213 uA
    Av. current (on 1x) = 28.818833 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   33.3849  |   33.4896  |   33.5346
    up-down    (mC)|   -0.1544  |   -0.0593  |   -0.0003
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 175.51529 Hz  |      6071.3 /mC  |  175.515 Hz  |    203324  |     1   |      6090.3 /mC
        2      | 19495.504 Hz  |    674369.9 /mC  |    9.748 Hz  |  22584379  |  2000   |    676484.8 /mC
        3      | 851.17715 Hz  |     29443.1 /mC  |  851.177 Hz  |    986038  |     1   |     29535.4 /mC
        4      | 26051.114 Hz  |    901135.4 /mC  |   13.026 Hz  |  30178663  |  2000   |    903961.5 /mC
        5      | 22.811704 Hz  |       789.1 /mC  |   22.812 Hz  |     26426  |     1   |       791.6 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 12.635954 Hz  |       437.1 /mC  |   12.636 Hz  | 14638.0  |     1   |       438.5 /mC
        8    | 1024.0 Hz  |     35421.2 /mC  |    0.016 Hz  |   1186243  | 65535   |     35532.3 /mC
        output                       866.848 Hz
    Av. deadtime from accepted triggers = 0.1557
    Av. deadtime from gated scalers = 0.1514
    Accepted triggers  = 1004192.00000
    Rate of Left Arm Pulser for electronic DT  = 10.17575
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.17575
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 41879.445
    Rate of Right Arm Strobe  = 19756.405
        Signal     |    Charge   (C)   
       upstream    |    0.0333077     
       upstream 3x |    0.0334599     
       upstream 10x|    0.0335345     
      downstream   |    0.0334621   
     downstream 3x |    0.0335192   
     downstream 10x|    0.0335348    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2843 at Mon Mar 12 11:04:24 EST 2001
    Right Arm D1 momentum                    : 1.6138
    Right Arm arm angle                      : 45.2401
    Left Arm D1 momentum                      : 2.466
    Left Arm arm angle                        : 27.6494
    Tiefenbach Hall A energy                : 3399.18
    Right Arm arm mispointing (HPT)          : -1.16978
    Left Arm arm mispointing (HPT)            : 5.67939
    Right Arm Q1 power supply current        : 1213.42
    Right Arm Q1 momentum                    : 1.61372
    Right Arm Q1 gauss meter                 : -0.03024
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 694.467
    Right Arm Q2 momentum                    : 1.61366
    Right Arm Q2 gauss meter                 : 0.365
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 554.964
    Right Arm D1 momentum                    : 1.6138
    Right Arm D1 NMR                         : 0.598862
    Right Arm Q3 power supply current        : 642.269
    Right Arm Q3 momentum                    : 1.61411
    Right Arm Q3 gauss meter                 : 0.288
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1855.35
    Left Arm Q1 momentum                      : 2.46613
    Left Arm Q1 gauss meter                   : 0.15753
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1061.84
    Left Arm Q2 momentum                      : 2.46596
    Left Arm Q2 gauss meter                   : -0.5592
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 848.587
    Left Arm D1 momentum                      : 2.466
    Left Arm D1 NMR                           : 0.912691
    Left Arm Q3 power supply current          : 981.63
    Left Arm Q3 momentum                      : 2.46567
    Left Arm Q3 gauss meter                   : 0.49
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 28.9607
    Current on Unser monitor                : 37.5522
    Current on Upstream bcm                 : 28.8427
    Current on Downstream bcm               : 29.0788
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 29.2585
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.18
    Tiefenbach Hall C energy                : 884.441
    Delta(E)/E width (MV_AI_DXWID)          : 1.18982
    IPM1C12.XPOS                            : 0.00137126
    IPM1H04A.XPOS                           : -0.160129
    IPM1H04A.YPOS                           : 0.497395
    IPM1H04B.XPOS                           : -0.0802053
    IPM1H04B.YPOS                           : -0.00145193
    Right Arm Arm Collimator                 : 0.615186
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -1469
     HacR_VPM_LVDT:VALr                     : 629
     HacR_HPE1313A:0_Ch58                   : -0.525879
     HacR_HPE1313A:0_Ch55                   : 22.8516
     HacR_HPE1313A:0_Ch54                   : -0.904785
     HacR_alignROLL                         : -0.424645
     HacR_alignPITCH                        : -0.0280167
     HacR_alignHPT                          : -1.17006
     HacL_HPM_LVDT:VALr                     : -8483
     HacL_VPM_LVDT:VALr                     : 1240
     HacL_HPE1313A:0_Ch58                   : -0.151367
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.21875
     HacL_alignROLL                         : 0.138759
     HacL_alignPITCH                        : -0.109379
     HacL_alignHPT                          : 5.68003
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 64
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 20.53
    haH2_P_Exhaust_R                         : 21
    haH2_P_Fill_Bottle_R                     : 21.09
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -280
    haD2_P_Exhaust_R                         : 18.91
    haD2_P_Fill_Bottle_R                     : 39.08
    haD2_DP_Fill_Exhaust_R                   : 0.0744
    haSC200_6_Sensor_1_R                     : 241.16
    haSC200_6_Sensor_2_R                     : 27.25
    haSC200_6_Sensor_3_R                     : 38.09
    haSC200_6_Sensor_4_R                     : 40.69
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.66
    haITC502_1_Sensor_2_R                    : 82.94
    haITC502_1_Sensor_3_R                    : 76.9
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19
    haITC502_4_Sensor_1_R                    : 
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 90.88
    haITC502_5_Sensor_2_R                    : 82.15
    haITC502_5_Sensor_3_R                    : 266.6
    haITC502_6_Sensor_1_R                    : 98.23
    haITC502_6_Sensor_2_R                    : 82.05
    haITC502_6_Sensor_3_R                    : 28.34
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 205
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON