Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 17:34:26 on March 12, 2001
Entry number 58583
keyword=Start_Run_2861_RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=sing21,mode=singles,Lmom=1.3688,Rmom=-1.3688,Ene=3.399,Angle_R=52.971,Angle_L=52.951
Beginning-of-run EPICS data for Run Number 2861 at Mon Mar 12 17:34:04 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=2000,ps3=1,ps4=2000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current :
Right Arm Q1 momentum : 1.36884
Right Arm Q1 gauss meter : -0.02569
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 588.89
Right Arm Q2 momentum : 1.36834
Right Arm Q2 gauss meter : 0.3096
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 467.89
Right Arm D1 momentum : 1.3688
Right Arm D1 NMR : 0.507945
Right Arm Q3 power supply current : 544.571
Right Arm Q3 momentum : 1.36858
Right Arm Q3 gauss meter : 0.2442
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1029.59
Left Arm Q1 momentum : 1.36854
Left Arm Q1 gauss meter : 0.08787
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 589.341
Left Arm Q2 momentum : 1.36865
Left Arm Q2 gauss meter : -0.3108
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 457.476
Left Arm D1 momentum : 1.36881
Left Arm D1 NMR :
Left Arm Q3 power supply current : 544.905
Left Arm Q3 momentum : 1.3687
Left Arm Q3 gauss meter : 0.2721
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 14.6004
Current on Unser monitor : 21.7635
Current on Upstream bcm : 14.6431
Current on Downstream bcm : 14.5576
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 14.6202
Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
Radiator 5V Linear Supply : 5.02808
Radiator Encoder : 0.156288
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 71
haL3_Fan_frequency_R : 37.5
haSC200_6_Sensor_1_R : 241.26
haSC200_6_Sensor_2_R : 27.25
haSC200_6_Sensor_3_R : 38.19
haSC200_6_Sensor_4_R : 40.76
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.76
haITC502_1_Sensor_2_R : 83.06
haITC502_1_Sensor_3_R : 76.76
haITC502_4_Sensor_1_R : 84.2
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 91.12
haITC502_5_Sensor_2_R : 82.49
haITC502_5_Sensor_3_R : 265.8
haITC502_6_Sensor_1_R : 98.15
haITC502_6_Sensor_2_R : 81.72
haITC502_6_Sensor_3_R : 28.5
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -4567
HacR_VPM_LVDT:VALr : 668
HacR_HPE1313A:0_Ch58 : -0.51416
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.81543
HacR_alignROLL : -0.334858
HacR_alignPITCH : -0.0402046
HacR_alignHPT : 2.24545
HacL_HPM_LVDT:VALr : -8212
HacL_VPM_LVDT:VALr : -306
HacL_HPE1313A:0_Ch58 : -0.284668
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 :
HacL_alignROLL : -0.0214521
HacL_alignPITCH : 0.00879733
HacL_alignHPT : 5.45189
Right Arm Angle Floor Angle : 53
Right Arm Angle Vernier : -36.5
Right Arm Scattering Angle : 52.9714
Left Arm Angle Floor Angle : 53
Left Arm Angle Vernier : 29
Left Arm Scattering Angle : 52.9512
Wien angle : 51.3832
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1151.4
Wien field : 33.611
Laser attenuation Hall A : 151
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88