    User name adev

    Log entry time 07:05:08 on March 13, 2001

    Entry number 58649

    keyword=End_of_Run_2880
    ****************************
     Run Number: 2880
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kinematics17,mode=coincidence,Lmom=1.98600,Rmom=-0.84600,Ene=3.399,Angle_R=47.995,Angle_L=12.473
    
    Time of run = 52.03138 min
    Av. current (on 3x) = 75.821841 uA
    Av. current (on 1x) = 75.630129 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  236.1084  |  236.7069  |  -130.5481
    up-down    (mC)|   -1.2095  |   -0.0891  |  -10.2327
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 7178.1683 Hz  |     94671.5 /mC  |    9.766 Hz  |  22409400  |   735   |     94911.5 /mC
        2      | 29887.085 Hz  |    394175.2 /mC  |    9.224 Hz  |  93303977  |  3240   |    395174.3 /mC
        3      | 297799.08 Hz  |   3927616.1 /mC  |    9.638 Hz  | 929693830  | 30900   |   3937572.0 /mC
        4      | 89544.411 Hz  |   1180984.4 /mC  |    9.506 Hz  | 279547160  |  9420   |   1183978.0 /mC
        5      | 207.32168 Hz  |      2734.3 /mC  |  207.322 Hz  |    647234  |     1   |      2741.3 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 197.14289 Hz  |      2600.1 /mC  |  197.143 Hz  | 615457.0  |     1   |      2606.7 /mC
        8    | 1024.0 Hz  |     13505.3 /mC  |    0.016 Hz  |   3196808  | 65535   |     13539.6 /mC
        output                       240.221 Hz
    Av. deadtime from accepted triggers = 0.0202
    Av. deadtime from gated scalers = -0.0565
    Accepted triggers  = 749943.00000
    Rate of Left Arm Pulser for electronic DT  = 10.178793
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 9.9904455
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.018503949
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 561403.61
    Rate of Right Arm Strobe  = 38850.738
        Signal     |    Charge   (C)   
       upstream    |    0.2355036     
       upstream 3x |    0.2366623     
       upstream 10x|    -0.1356645     
      downstream   |    0.2367131   
     downstream 3x |    0.2367514   
     downstream 10x|    -0.1254318    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2880 at Tue Mar 13 07:04:55 EST 2001
    Right Arm D1 momentum                    : 0.845999
    Right Arm arm angle                      : 47.9952
    Left Arm D1 momentum                      : 1.986
    Left Arm arm angle                        : 12.473
    Tiefenbach Hall A energy                : 3399.21
    Right Arm arm mispointing (HPT)          : -0.842064
    Left Arm arm mispointing (HPT)            : 3.9381
    Right Arm Q1 power supply current        : 636.055
    Right Arm Q1 momentum                    : 0.845891
    Right Arm Q1 gauss meter                 : -0.015946
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 364.169
    Right Arm Q2 momentum                    : 0.846181
    Right Arm Q2 gauss meter                 : 0.19143
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 288.527
    Right Arm D1 momentum                    : 0.846
    Right Arm D1 NMR                         : 0.31394
    Right Arm Q3 power supply current        : 336.382
    Right Arm Q3 momentum                    : 0.845375
    Right Arm Q3 gauss meter                 : 0.15083
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1494.11
    Left Arm Q1 momentum                      : 1.98598
    Left Arm Q1 gauss meter                   : 0.12693
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 855.042
    Left Arm Q2 momentum                      : 1.9857
    Left Arm Q2 gauss meter                   : -0.4507
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 673.712
    Left Arm D1 momentum                      : 1.986
    Left Arm D1 NMR                           : 0.734894
    Left Arm Q3 power supply current          : 790.59
    Left Arm Q3 momentum                      : 1.98582
    Left Arm Q3 gauss meter                   : 0.3948
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 86.8239
    Current on Unser monitor                : 93.893
    Current on Upstream bcm                 : 86.963
    Current on Downstream bcm               : 86.6848
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 87.4112
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.19
    Tiefenbach Hall C energy                : 884.441
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.016132
    IPM1H04A.XPOS                           : -0.0754072
    IPM1H04A.YPOS                           : 0.58859
    IPM1H04B.XPOS                           : -0.0859363
    IPM1H04B.YPOS                           : 0.0256263
    Right Arm Arm Collimator                 : 0.615234
    Left Arm Arm Collimator                   : 0.616895
     HacR_HPM_LVDT:VALr                     : -1773
     HacR_VPM_LVDT:VALr                     : 522
     HacR_HPE1313A:0_Ch58                   : -0.521973
     HacR_HPE1313A:0_Ch55                   : 22.7051
     HacR_HPE1313A:0_Ch54                   : -0.885254
     HacR_alignROLL                         : -0.405037
     HacR_alignPITCH                        : -0.0323723
     HacR_alignHPT                          : -0.842064
     HacL_HPM_LVDT:VALr                     : -7055
     HacL_VPM_LVDT:VALr                     : 1657
     HacL_HPE1313A:0_Ch58                   : -0.229004
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : 0.104492
     HacL_alignROLL                         : 0.440767
     HacL_alignPITCH                        : -0.0603632
     HacL_alignHPT                          : 3.93836
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 68
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 20.18
    haH2_P_Exhaust_R                         : 20.66
    haH2_P_Fill_Bottle_R                     : 20.74
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.72
    haD2_P_Fill_Bottle_R                     : 38.75
    haD2_DP_Fill_Exhaust_R                   : 0.0743
    haSC200_6_Sensor_1_R                     : 241.14
    haSC200_6_Sensor_2_R                     : 27.22
    haSC200_6_Sensor_3_R                     : 38.19
    haSC200_6_Sensor_4_R                     : 40.76
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 82.87
    haITC502_1_Sensor_2_R                    : 82.18
    haITC502_1_Sensor_3_R                    : 75.84
    haITC502_2_Sensor_1_R                    : 18.99
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.23
    haITC502_4_Sensor_1_R                    : 83.8
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 90.29
    haITC502_5_Sensor_2_R                    : 81.59
    haITC502_5_Sensor_3_R                    : 264.7
    haITC502_6_Sensor_1_R                    : 97.3
    haITC502_6_Sensor_2_R                    : 81.06
    haITC502_6_Sensor_3_R                    : 27.89
    Right Arm Arm Collimator                 : 0.615186
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 433
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON