User name adev
Log entry time 16:00:32 on March 13, 2001
Entry number 58675
keyword=Start_Run_2888_RunType=Other,Tar=9foil-12C,Rad=out,comment=kinematics17,mode=singles,Lmom=1.98600,Rmom=-0.84600,Ene=3.399,Angle_R=47.995,Angle_L=12.473
Beginning-of-run EPICS data for Run Number 2888 at Tue Mar 13 16:00:21 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=220,ps3=12,ps4=240,ps5=5,ps6=65535,ps7=65535,ps8=12
Right Arm Q1 power supply current : 635.985
Right Arm Q1 momentum : 0.845798
Right Arm Q1 gauss meter : -0.01594
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 364.065
Right Arm Q2 momentum : 0.845939
Right Arm Q2 gauss meter : 0.19146
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 288.527
Right Arm D1 momentum : 0.846
Right Arm D1 NMR : 0.31394
Right Arm Q3 power supply current : 336.426
Right Arm Q3 momentum : 0.845485
Right Arm Q3 gauss meter : 0.15083
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1494.11
Left Arm Q1 momentum : 1.98598
Left Arm Q1 gauss meter : 0.12697
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 854.88
Left Arm Q2 momentum : 1.98532
Left Arm Q2 gauss meter : -0.4506
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 673.709
Left Arm D1 momentum : 1.986
Left Arm D1 NMR : 0.734893
Left Arm Q3 power supply current : 790.698
Left Arm Q3 momentum : 1.98609
Left Arm Q3 gauss meter : 0.3949
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 4.8058
Current on Unser monitor : 11.2376
Current on Upstream bcm : 4.80275
Current on Downstream bcm : 4.80885
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 4.87474
Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.168498
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.58
haSC200_6_Sensor_2_R : 27.52
haSC200_6_Sensor_3_R : 38.54
haSC200_6_Sensor_4_R : 40.98
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.59
haITC502_1_Sensor_2_R : 82.9
haITC502_1_Sensor_3_R : 76.43
haITC502_4_Sensor_1_R : 83.8
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 91.13
haITC502_5_Sensor_2_R : 82.35
haITC502_5_Sensor_3_R : 267.4
haITC502_6_Sensor_1_R : 98.03
haITC502_6_Sensor_2_R : 81.55
haITC502_6_Sensor_3_R : 27.95
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1782
HacR_VPM_LVDT:VALr : 537
HacR_HPE1313A:0_Ch58 : -0.520996
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.885742
HacR_alignROLL : -0.40553
HacR_alignPITCH : -0.0323723
HacR_alignHPT : -0.831708
HacL_HPM_LVDT:VALr : -7026
HacL_VPM_LVDT:VALr : 1705
HacL_HPE1313A:0_Ch58 : -0.227539
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : 0.10498
HacL_alignROLL : 0.441469
HacL_alignPITCH : -0.0618185
HacL_alignHPT : 3.90454
Right Arm Angle Floor Angle : 48
Right Arm Angle Vernier : -36
Right Arm Scattering Angle : 47.9951
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.4732
Wien angle : 51.3832
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1151.4
Wien field : 33.611
Laser attenuation Hall A : 130
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88