User name adev
Log entry time 16:19:10 on March 13, 2001
Entry number 58679
keyword=Start_Run_2890_RunType=Other,Tar=9foil-12C,Rad=out,comment=kinematics17,mode=singles,Lmom=1.98600,Rmom=-0.84600,Ene=3.399,Angle_R=47.995,Angle_L=12.473
Beginning-of-run EPICS data for Run Number 2890 at Tue Mar 13 16:19:00 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=220,ps3=12,ps4=240,ps5=5,ps6=65535,ps7=65535,ps8=12
Right Arm Q1 power supply current : 636.16
Right Arm Q1 momentum : 0.846031
Right Arm Q1 gauss meter : -0.015934
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 364.065
Right Arm Q2 momentum : 0.845941
Right Arm Q2 gauss meter : 0.19149
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 288.527
Right Arm D1 momentum : 0.846
Right Arm D1 NMR : 0.31394
Right Arm Q3 power supply current : 336.544
Right Arm Q3 momentum : 0.845783
Right Arm Q3 gauss meter : 0.15085
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1494.08
Left Arm Q1 momentum : 1.98593
Left Arm Q1 gauss meter : 0.12698
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 855.343
Left Arm Q2 momentum : 1.9864
Left Arm Q2 gauss meter : -0.4507
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 673.706
Left Arm D1 momentum : 1.986
Left Arm D1 NMR : 0.734893
Left Arm Q3 power supply current : 790.601
Left Arm Q3 momentum : 1.98584
Left Arm Q3 gauss meter : 0.3948
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 4.78462
Current on Unser monitor : 10.8726
Current on Upstream bcm : 4.77815
Current on Downstream bcm : 4.79109
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 4.84119
Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.163614
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 67.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.76
haSC200_6_Sensor_2_R : 27.57
haSC200_6_Sensor_3_R : 38.62
haSC200_6_Sensor_4_R : 41.06
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.57
haITC502_1_Sensor_2_R : 82.88
haITC502_1_Sensor_3_R : 76.73
haITC502_4_Sensor_1_R : 83.9
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 91.12
haITC502_5_Sensor_2_R : 82.32
haITC502_5_Sensor_3_R : 267.5
haITC502_6_Sensor_1_R : 98.06
haITC502_6_Sensor_2_R : 81.58
haITC502_6_Sensor_3_R : 27.94
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616895
HacR_HPM_LVDT:VALr : -1787
HacR_VPM_LVDT:VALr : 529
HacR_HPE1313A:0_Ch58 : -0.521973
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.885742
HacR_alignROLL : -0.405966
HacR_alignPITCH : -0.032888
HacR_alignHPT : -0.824743
HacL_HPM_LVDT:VALr : -7027
HacL_VPM_LVDT:VALr : 1704
HacL_HPE1313A:0_Ch58 : -0.226562
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : 0.105957
HacL_alignROLL : 0.442398
HacL_alignPITCH : -0.0627646
HacL_alignHPT : 3.90853
Right Arm Angle Floor Angle : 48
Right Arm Angle Vernier : -36
Right Arm Scattering Angle : 47.9951
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.4732
Wien angle : 51.3832
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1151.4
Wien field : 33.611
Laser attenuation Hall A : 130
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88