User name adev
Log entry time 16:35:30 on March 13, 2001
Entry number 58684
keyword=Start_Run_2892_RunType=Other,Tar=9foil-12C,Rad=out,comment=kinematics17,mode=singles,Lmom=1.98600,Rmom=-0.84600,Ene=3.399,Angle_R=47.995,Angle_L=12.473
Beginning-of-run EPICS data for Run Number 2892 at Tue Mar 13 16:35:20 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=220,ps3=12,ps4=240,ps5=5,ps6=65535,ps7=65535,ps8=12
Right Arm Q1 power supply current : 636.16
Right Arm Q1 momentum : 0.846031
Right Arm Q1 gauss meter : -0.015949
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 364.179
Right Arm Q2 momentum : 0.846204
Right Arm Q2 gauss meter : 0.19142
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 288.528
Right Arm D1 momentum : 0.846
Right Arm D1 NMR : 0.31394
Right Arm Q3 power supply current : 336.725
Right Arm Q3 momentum : 0.846237
Right Arm Q3 gauss meter : 0.15089
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1494.29
Left Arm Q1 momentum : 1.98621
Left Arm Q1 gauss meter : 0.12697
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 855.125
Left Arm Q2 momentum : 1.98589
Left Arm Q2 gauss meter : -0.4506
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 673.703
Left Arm D1 momentum : 1.986
Left Arm D1 NMR : 0.734893
Left Arm Q3 power supply current : 790.7
Left Arm Q3 momentum : 1.98609
Left Arm Q3 gauss meter : 0.3948
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 4.64095
Current on Unser monitor : 11.3218
Current on Upstream bcm : 4.67287
Current on Downstream bcm : 4.60904
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 4.66715
Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
Radiator 5V Linear Supply : 5.01099
Radiator Encoder : 0.166056
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.9
haSC200_6_Sensor_2_R : 27.71
haSC200_6_Sensor_3_R : 38.65
haSC200_6_Sensor_4_R : 41.06
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.57
haITC502_1_Sensor_2_R : 82.88
haITC502_1_Sensor_3_R : 76.05
haITC502_4_Sensor_1_R : 83.9
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 91.09
haITC502_5_Sensor_2_R : 82.37
haITC502_5_Sensor_3_R : 267.5
haITC502_6_Sensor_1_R : 98.07
haITC502_6_Sensor_2_R : 81.53
haITC502_6_Sensor_3_R : 27.95
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1789
HacR_VPM_LVDT:VALr : 521
HacR_HPE1313A:0_Ch58 : -0.520508
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.885254
HacR_alignROLL : -0.404431
HacR_alignPITCH : -0.0334038
HacR_alignHPT : -0.824499
HacL_HPM_LVDT:VALr : -7029
HacL_VPM_LVDT:VALr : 1700
HacL_HPE1313A:0_Ch58 : -0.227539
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : 0.105469
HacL_alignROLL : 0.442171
HacL_alignPITCH : -0.0634199
HacL_alignHPT : 3.90864
Right Arm Angle Floor Angle : 48
Right Arm Angle Vernier : -36
Right Arm Scattering Angle : 47.9951
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.4732
Wien angle : 51.3832
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1151.4
Wien field : 33.611
Laser attenuation Hall A : 130
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88