    User name adev

    Log entry time 14:48:50 on March 14, 2001

    Entry number 58776

    keyword=End_of_Run_2923
    ****************************
     Run Number: 2923
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kinematics17,mode=coincidence,Lmom=1.98600,Rmom=-0.84600,Ene=3.399,Angle_R=47.995,Angle_L=12.473
    
    
    Time of run = 13.170963 min
    Av. current (on 3x) = 60.628948 uA
    Av. current (on 1x) = 60.492031 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   47.8043  |   47.9125  |   42.3007
    up-down    (mC)|   -0.2439  |    0.0002  |   -0.9588
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 5769.3552 Hz  |     95158.4 /mC  |    6.410 Hz  |   4559278  |   900   |     95373.8 /mC
        2      | 25748.09 Hz  |    424683.1 /mC  |    7.357 Hz  |  20347629  |  3500   |    425644.3 /mC
        3      | 245821.14 Hz  |   4054517.5 /mC  |    6.984 Hz  | 194262070  | 35200   |   4063694.5 /mC
        4      | 73276.899 Hz  |   1208612.4 /mC  |    7.713 Hz  |  57907642  |  9500   |   1211348.0 /mC
        5      | 177.62684 Hz  |      2929.7 /mC  |  177.627 Hz  |    140371  |     1   |      2936.4 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 167.44409 Hz  |      2761.8 /mC  |  167.444 Hz  | 132324.0  |     1   |      2768.0 /mC
        8    | 1024.0 Hz  |     16889.6 /mC  |    0.016 Hz  |    809224  | 65535   |     16927.8 /mC
        output                       201.418 Hz
    Av. deadtime from accepted triggers = 0.0218
    Av. deadtime from gated scalers = 0.0390
    Accepted triggers  = 159172.00000
    Rate of Left Arm Pulser for electronic DT  = 10.182753
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.014453
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.016527899
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 455873.07
    Rate of Right Arm Strobe  = 32514.961
        Signal     |    Charge   (C)   
       upstream    |    0.0476824     
       upstream 3x |    0.0479126     
       upstream 10x|    0.0418213     
      downstream   |    0.0479263   
     downstream 3x |    0.0479124   
     downstream 10x|    0.0427801    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2923 at Wed Mar 14 14:48:39 EST 2001
    Right Arm D1 momentum                    : 0.846
    Right Arm arm angle                      : 47.9953
    Left Arm D1 momentum                      : 1.986
    Left Arm arm angle                        : 12.4729
    Tiefenbach Hall A energy                : 3399.19
    Right Arm arm mispointing (HPT)          : -0.858472
    Left Arm arm mispointing (HPT)            : 3.94585
    Right Arm Q1 power supply current        : 636.055
    Right Arm Q1 momentum                    : 0.845891
    Right Arm Q1 gauss meter                 : -0.015943
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 364.016
    Right Arm Q2 momentum                    : 0.845827
    Right Arm Q2 gauss meter                 : 0.19145
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 288.534
    Right Arm D1 momentum                    : 0.846
    Right Arm D1 NMR                         : 0.313941
    Right Arm Q3 power supply current        : 336.6
    Right Arm Q3 momentum                    : 0.845923
    Right Arm Q3 gauss meter                 : 0.15086
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1494.19
    Left Arm Q1 momentum                      : 1.98607
    Left Arm Q1 gauss meter                   : 0.12695
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 854.987
    Left Arm Q2 momentum                      : 1.98557
    Left Arm Q2 gauss meter                   : -0.4589
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 673.716
    Left Arm D1 momentum                      : 1.986
    Left Arm D1 NMR                           : 0.734894
    Left Arm Q3 power supply current          : 790.725
    Left Arm Q3 momentum                      : 1.98615
    Left Arm Q3 gauss meter                   : 0.3949
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.0419858
    Current on Unser monitor                : 6.15019
    Current on Upstream bcm                 : 0.0484537
    Current on Downstream bcm               : 0.0355179
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 0.00143682
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.19
    Tiefenbach Hall C energy                : 884.419
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0
    IPM1H04B.XPOS                           : 0
    IPM1H04B.YPOS                           : 0
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -1758
     HacR_VPM_LVDT:VALr                     : 533
     HacR_HPE1313A:0_Ch58                   : -0.521484
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.887695
     HacR_alignROLL                         : -0.407614
     HacR_alignPITCH                        : -0.0326876
     HacR_alignHPT                          : -0.857385
     HacL_HPM_LVDT:VALr                     : -7060
     HacL_VPM_LVDT:VALr                     : 1704
     HacL_HPE1313A:0_Ch58                   : -0.226562
     HacL_HPE1313A:0_Ch55                   : 23.3398
     HacL_HPE1313A:0_Ch54                   : 0.103027
     HacL_alignROLL                         : 0.439758
     HacL_alignPITCH                        : -0.0624732
     HacL_alignHPT                          : 3.94332
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 66
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 21.46
    haH2_P_Exhaust_R                         : 21.83
    haH2_P_Fill_Bottle_R                     : 21.89
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 19.59
    haD2_P_Fill_Bottle_R                     : 40.54
    haD2_DP_Fill_Exhaust_R                   : 0.0744
    haSC200_6_Sensor_1_R                     : 241.29
    haSC200_6_Sensor_2_R                     : 27.15
    haSC200_6_Sensor_3_R                     : 38.44
    haSC200_6_Sensor_4_R                     : 40.86
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 82.8
    haITC502_1_Sensor_2_R                    : 82.11
    haITC502_1_Sensor_3_R                    : 75.26
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.01
    haITC502_4_Sensor_1_R                    : 83.5
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 90.26
    haITC502_5_Sensor_2_R                    : 81.61
    haITC502_5_Sensor_3_R                    : 264.2
    haITC502_6_Sensor_1_R                    : 97.05
    haITC502_6_Sensor_2_R                    : 80.66
    haITC502_6_Sensor_3_R                    : 27.84
    Right Arm Arm Collimator                 : 0.615186
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 150
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON