    User name adev

    Log entry time 23:23:05 on March 15, 2001

    Entry number 58869

    keyword=End_of_Run_2959
    ****************************
     Run Number: 2959
    End of Run Comment:
    RunType=Optics,Tar=9foil-12C,Rad=out,comment=kinematics18,mode=singles,Lmom=1.8930,Rmom=-0.788000,Ene=3.399,Angle_R=55.871,Angle_L=12.473, BPMB
    x=+0.498, y=-0.009
    
    
    Time of run = 4.4462402 min
    Av. current (on 3x) = 19.454265 uA
    Av. current (on 1x) = 19.393914 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    5.1738  |    5.1899  |    5.1997
    up-down    (mC)|   -0.0169  |   -0.0067  |    0.0022
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 236.17333 Hz  |     12139.9 /mC  |    0.262 Hz  |     63005  |   900   |     12177.7 /mC
        2      | 4408.8674 Hz  |    226627.3 /mC  |    1.260 Hz  |   1176173  |  3500   |    227332.5 /mC
        3      | 15746.012 Hz  |    809386.1 /mC  |    0.447 Hz  |   4200633  | 35200   |    811904.8 /mC
        4      | 7546.852 Hz  |    387927.9 /mC  |    0.794 Hz  |   2013307  |  9500   |    389135.1 /mC
        5      | 10.566981 Hz  |       543.2 /mC  |   10.567 Hz  |      2819  |     1   |       544.9 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.374849 Hz  |        19.3 /mC  |    0.375 Hz  | 99.999999  |     1   |        19.3 /mC
        8    | 1024.0 Hz  |     52636.3 /mC  |    0.016 Hz  |    273177  | 65535   |     52800.1 /mC
        output                       542.856 Hz
    Av. deadtime from accepted triggers = -39.7100
    Av. deadtime from gated scalers = 0.0737
    Accepted triggers  = 144820.00000
    Rate of Left Arm Pulser for electronic DT  = 10.192132
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.184635
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00073556455
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 33269.675
    Rate of Right Arm Strobe  = 4675.1298
        Signal     |    Charge   (C)   
       upstream    |    0.0051653     
       upstream 3x |    0.0051866     
       upstream 10x|    0.0052008     
      downstream   |    0.0051822   
     downstream 3x |    0.0051933   
     downstream 10x|    0.0051986    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2959 at Thu Mar 15 23:22:46 EST 2001
    Right Arm D1 momentum                    : 0.788
    Right Arm arm angle                      : 55.8711
    Left Arm D1 momentum                      : 1.89301
    Left Arm arm angle                        : 12.4732
    Tiefenbach Hall A energy                : 3399.18
    Right Arm arm mispointing (HPT)          : 2.38133
    Left Arm arm mispointing (HPT)            : 3.9114
    Right Arm Q1 power supply current        : 592.515
    Right Arm Q1 momentum                    : 0.787987
    Right Arm Q1 gauss meter                 : -0.014864
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 338.947
    Right Arm Q2 momentum                    : 0.787576
    Right Arm Q2 gauss meter                 : 0.17834
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 268.653
    Right Arm D1 momentum                    : 0.788
    Right Arm D1 NMR                         : 0.292417
    Right Arm Q3 power supply current        : 313.546
    Right Arm Q3 momentum                    : 0.787984
    Right Arm Q3 gauss meter                 : 0.14053
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1424.22
    Left Arm Q1 momentum                      : 1.89307
    Left Arm Q1 gauss meter                   : 0.12111
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 814.887
    Left Arm Q2 momentum                      : 1.89245
    Left Arm Q2 gauss meter                   : -0.4295
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 640.191
    Left Arm D1 momentum                      : 1.89301
    Left Arm D1 NMR                           : 0.700503
    Left Arm Q3 power supply current          : 753.692
    Left Arm Q3 momentum                      : 1.89313
    Left Arm Q3 gauss meter                   : 0.3762
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.0401923
    Current on Unser monitor                : 8.27482
    Current on Upstream bcm                 : 0.0475049
    Current on Downstream bcm               : 0.0333349
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 72.5658
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.18
    Tiefenbach Hall C energy                : 884.125
    Delta(E)/E width (MV_AI_DXWID)          : 32.5121
    IPM1C12.XPOS                            : 0
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0
    IPM1H04B.XPOS                           : 0
    IPM1H04B.YPOS                           : 0
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -4737
     HacR_VPM_LVDT:VALr                     : 580
     HacR_HPE1313A:0_Ch58                   : -0.515625
     HacR_HPE1313A:0_Ch55                   : 22.5586
     HacR_HPE1313A:0_Ch54                   : -0.790527
     HacR_alignROLL                         : -0.309455
     HacR_alignPITCH                        : -0.0372433
     HacR_alignHPT                          : 2.38157
     HacL_HPM_LVDT:VALr                     : -7033
     HacL_VPM_LVDT:VALr                     : 1774
     HacL_HPE1313A:0_Ch58                   : -0.225098
     HacL_HPE1313A:0_Ch55                   : 23.3887
     HacL_HPE1313A:0_Ch54                   : 0.106934
     HacL_alignROLL                         : 0.443011
     HacL_alignPITCH                        : -0.0637829
     HacL_alignHPT                          : 3.91271
    haBDSPOS                                 : 2.50444e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 65.5
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 19.85
    haH2_P_Exhaust_R                         : 20.17
    haH2_P_Fill_Bottle_R                     : 20.32
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.27
    haD2_P_Fill_Bottle_R                     : 37.89
    haD2_DP_Fill_Exhaust_R                   : 0.0745
    haSC200_6_Sensor_1_R                     : 241.39
    haSC200_6_Sensor_2_R                     : 27.2
    haSC200_6_Sensor_3_R                     : 38.57
    haSC200_6_Sensor_4_R                     : 40.94
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 84.14
    haITC502_1_Sensor_2_R                    : 83.45
    haITC502_1_Sensor_3_R                    : 77.15
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 18.99
    haITC502_4_Sensor_1_R                    : 84.3
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 91.63
    haITC502_5_Sensor_2_R                    : 82.9
    haITC502_5_Sensor_3_R                    : 267.1
    haITC502_6_Sensor_1_R                    : 98.83
    haITC502_6_Sensor_2_R                    : 82.25
    haITC502_6_Sensor_3_R                    : 27.96
    Right Arm Arm Collimator                 : 0.615186
    Left Arm Arm Collimator                   : 0.616846
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 120
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF