• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 04:30:53 on March 17, 2001

    Entry number 58928

    keyword=Start_Run_2979_RunType=Other,Tar=BeO,Rad=out,comment=kinematics18,mode=coincidence,Lmom=1.8930,Rmom=-0.788000,Ene=3.399,Angle_R=55.871,Angle_L=12.473
    Beginning-of-run EPICS data for Run Number 2979 at Sat Mar 17 04:30:34 EST 2001
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=900,ps2=3500,ps3=35200,ps4=9500,ps5=1,ps6=65535,ps7=65535,ps8=10
    
    
    
    Right Arm Q1 power supply current        : 592.585
    Right Arm Q1 momentum                    : 0.78808
    Right Arm Q1 gauss meter                 : -0.014854
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 339.039
    Right Arm Q2 momentum                    : 0.787791
    Right Arm Q2 gauss meter                 : 0.17838
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 268.65
    Right Arm D1 momentum                    : 0.788
    Right Arm D1 NMR                         : 0.292417
    Right Arm Q3 power supply current        : 313.733
    Right Arm Q3 momentum                    : 0.788454
    Right Arm Q3 gauss meter                 : 0.14063
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1424.15
    Left Arm Q1 momentum                      : 1.89298
    Left Arm Q1 gauss meter                   : 0.12108
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 815.045
    Left Arm Q2 momentum                      : 1.89281
    Left Arm Q2 gauss meter                   : -0.4295
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 640.181
    Left Arm D1 momentum                      : 1.89299
    Left Arm D1 NMR                           : 0.700496
    Left Arm Q3 power supply current          : 753.757
    Left Arm Q3 momentum                      : 1.8933
    Left Arm Q3 gauss meter                   : 0.3763
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 9.92494
    Current on Unser monitor                : 15.7642
    Current on Upstream bcm                 : 9.92688
    Current on Downstream bcm               : 9.86311
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 48.6869
    Beam energy                             : 3404.8
    MBSY1c magnet current (amp)             : 141.8
     Radiator 5V Linear Supply              : 5.00122
     Radiator Encoder                       : 0.15873
    haBDSPOS                                 : 190450
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 68.5
    haL3_Fan_frequency_R                     : 24.5
    haSC200_6_Sensor_1_R                     : 241.88
    haSC200_6_Sensor_2_R                     : 27.07
    haSC200_6_Sensor_3_R                     : 38.98
    haSC200_6_Sensor_4_R                     : 41.06
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.17
    haITC502_1_Sensor_2_R                    : 82.47
    haITC502_1_Sensor_3_R                    : 75.71
    haITC502_4_Sensor_1_R                    : 83.6
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 90.72
    haITC502_5_Sensor_2_R                    : 81.98
    haITC502_5_Sensor_3_R                    : 269.3
    haITC502_6_Sensor_1_R                    : 97.54
    haITC502_6_Sensor_2_R                    : 81
    haITC502_6_Sensor_3_R                    : 
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -4743
     HacR_VPM_LVDT:VALr                     : 583
     HacR_HPE1313A:0_Ch58                   : -0.51416
     HacR_HPE1313A:0_Ch55                   : 22.6562
     HacR_HPE1313A:0_Ch54                   : -0.79834
     HacR_alignROLL                         : -0.317343
     HacR_alignPITCH                        : -0.0394877
     HacR_alignHPT                          : 2.39273
     HacL_HPM_LVDT:VALr                     : -7081
     HacL_VPM_LVDT:VALr                     : 1779
     HacL_HPE1313A:0_Ch58                   : -0.225586
     HacL_HPE1313A:0_Ch55                   : 23.3887
     HacL_HPE1313A:0_Ch54                   : 0.106934
     HacL_alignROLL                         : 0.443011
     HacL_alignPITCH                        : -0.0642195
     HacL_alignHPT                          : 3.96634
    Right Arm Angle Floor Angle               : 55.5
    Right Arm Angle Vernier                   : 33
    Right Arm Scattering Angle                : 55.871
    Left Arm Angle Floor Angle                 : 12.5
    Left Arm Angle Vernier                     : 31
    Left Arm Scattering Angle                  : 12.4728
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 136
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88