User name adev
Log entry time 18:00:26 on March 17, 2001
Entry number 58947
keyword=Start_Run_2985_RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kinematics18,mode=coincidence,Lmom=1.8930,Rmom=-0.788000,Ene=3.399,Angle_R=55.871,Angle_L=12.473
Beginning-of-run EPICS data for Run Number 2985 at Sat Mar 17 17:50:09 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=900,ps2=3500,ps3=35200,ps4=9500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 592.62
Right Arm Q1 momentum : 0.788127
Right Arm Q1 gauss meter : -0.01485
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 339.069
Right Arm Q2 momentum : 0.787859
Right Arm Q2 gauss meter : 0.17835
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 268.651
Right Arm D1 momentum : 0.788
Right Arm D1 NMR : 0.292417
Right Arm Q3 power supply current : 313.742
Right Arm Q3 momentum : 0.788478
Right Arm Q3 gauss meter : 0.14063
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1424.11
Left Arm Q1 momentum : 1.89294
Left Arm Q1 gauss meter : 0.12107
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 815.025
Left Arm Q2 momentum : 1.89277
Left Arm Q2 gauss meter : -0.4295
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 640.188
Left Arm D1 momentum : 1.89299
Left Arm D1 NMR : 0.700497
Left Arm Q3 power supply current : 753.665
Left Arm Q3 momentum : 1.89307
Left Arm Q3 gauss meter : 0.3763
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 87.0413
Current on Unser monitor : 93.7703
Current on Upstream bcm : 87.1697
Current on Downstream bcm : 86.913
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 150.823
Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
Radiator 5V Linear Supply : 4.9768
Radiator Encoder : 0.15873
haBDSPOS :
haL1_Fan_frequency_R :
haL2_Fan_frequency_R :
haL3_Fan_frequency_R :
haSC200_6_Sensor_1_R :
haSC200_6_Sensor_2_R :
haSC200_6_Sensor_3_R :
haSC200_6_Sensor_4_R :
haHe_Omega_DPG_Sensor_R :
haITC502_1_Sensor_1_R :
haITC502_1_Sensor_2_R :
haITC502_1_Sensor_3_R :
haITC502_4_Sensor_1_R :
haITC502_4_Sensor_2_R :
haITC502_4_Sensor_3_R :
haITC502_5_Sensor_1_R :
haITC502_5_Sensor_2_R :
haITC502_5_Sensor_3_R :
haITC502_6_Sensor_1_R :
haITC502_6_Sensor_2_R :
haITC502_6_Sensor_3_R : CAC: no conn err="Connection timed out" CAC: ... Unable to connect to internet host or service ... CAC: for haITC502_6_Sensor_3_R on hallasc13.jlab.org CAC: ignored search reply- proceeding
Right Arm Arm Collimator : 0.615234
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4725
HacR_VPM_LVDT:VALr : 615
HacR_HPE1313A:0_Ch58 : -0.513672
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.800293
HacR_alignROLL : -0.319432
HacR_alignPITCH : -0.0398026
HacR_alignHPT : 2.37394
HacL_HPM_LVDT:VALr : -7051
HacL_VPM_LVDT:VALr : 1797
HacL_HPE1313A:0_Ch58 : -0.225586
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : 0.106445
HacL_alignROLL : 0.442773
HacL_alignPITCH : -0.0626913
HacL_alignHPT : 3.93338
Right Arm Angle Floor Angle : 55.5
Right Arm Angle Vernier : 33
Right Arm Scattering Angle : 55.8711
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.473
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 410
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88