Log entry time 08:24:33 on March18,2001
Entry number 58974
keyword=to check VDC efficiency...
I didn't think about this until the end of my shift, so here I
pass it along... the following might be worth a 10 minute run.
Reduce the beam current to 10 microamps and reduce singles pre-
scale factors so that you can take 50K events quickly. Then,
to analyze, you can use the old, clunky "ha_analyzer":
Login to adaqh2 (HP) as "adaq", type "goonlana" to go to
correct directory, type "ha_analyzer" and answer questions.
(You can type "last_run" to find latest run location, you
must enter full-path-name as one of the answers).
Analyze 50K, then in paw use a kumac like vdc_2992.kumac
(appropriately modified). If the efficiency is near 1.0, you
know there is no lasting chamber problem.