User name adev
Log entry time 17:57:39 on March 18, 2001
Entry number 58983
keyword=Start_Run_2998_RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kinematics18,mode=coincidence,Lmom=1.8930,Rmom=-0.788000,Ene=3.399,Angle_R=55.871,Angle_L=12.473
Beginning-of-run EPICS data for Run Number 2998 at Sun Mar 18 17:57:28 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=900,ps2=3500,ps3=35200,ps4=9500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 592.585
Right Arm Q1 momentum : 0.78808
Right Arm Q1 gauss meter : -0.014856
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 338.957
Right Arm Q2 momentum : 0.787599
Right Arm Q2 gauss meter : 0.17833
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 268.649
Right Arm D1 momentum : 0.788002
Right Arm D1 NMR : 0.292417
Right Arm Q3 power supply current : 313.326
Right Arm Q3 momentum : 0.787432
Right Arm Q3 gauss meter : 0.14059
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1424.15
Left Arm Q1 momentum : 1.89294
Left Arm Q1 gauss meter : 0.12109
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 814.894
Left Arm Q2 momentum : 1.89246
Left Arm Q2 gauss meter : -0.4295
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 640.187
Left Arm D1 momentum : 1.893
Left Arm D1 NMR : 0.700498
Left Arm Q3 power supply current : 753.596
Left Arm Q3 momentum : 1.89289
Left Arm Q3 gauss meter : 0.3764
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 84.6162
Current on Unser monitor : 90.8279
Current on Upstream bcm : 84.6787
Current on Downstream bcm : 84.5537
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 99.79
Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
Radiator 5V Linear Supply : 5.0525
Radiator Encoder : 0.161172
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 72.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.53
haSC200_6_Sensor_2_R : 26.95
haSC200_6_Sensor_3_R : 39.17
haSC200_6_Sensor_4_R : 41.08
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.51
haITC502_1_Sensor_2_R : 82.83
haITC502_1_Sensor_3_R : 76.34
haITC502_4_Sensor_1_R : 84
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 90.92
haITC502_5_Sensor_2_R : 82.29
haITC502_5_Sensor_3_R : 263.2
haITC502_6_Sensor_1_R : 0
haITC502_6_Sensor_2_R : 0
haITC502_6_Sensor_3_R : 0
Right Arm Arm Collimator : 0.615234
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4723
HacR_VPM_LVDT:VALr : 604
HacR_HPE1313A:0_Ch58 : -0.512695
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.800781
HacR_alignROLL : -0.319983
HacR_alignPITCH : -0.0406334
HacR_alignHPT : 2.37204
HacL_HPM_LVDT:VALr : -7074
HacL_VPM_LVDT:VALr : 1781
HacL_HPE1313A:0_Ch58 : -0.225586
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.106934
HacL_alignROLL : 0.443011
HacL_alignPITCH : -0.0633463
HacL_alignHPT : 3.95852
Right Arm Angle Floor Angle : 55.5
Right Arm Angle Vernier : 33
Right Arm Scattering Angle : 55.8711
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.4729
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 435
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88