User name adev
Log entry time 23:33:20 on March 18, 2001
Entry number 58995
keyword=Start_Run_3002_RunType=Optics,Tar=9foil-12C,Rad=out,comment=kinematics19,mode=singles,Lmom=1.8900,Rmom=-0.9270,Ene=3.399,Angle_R=45.707,Angle_L=13.554
Beginning-of-run EPICS data for Run Number 3002 at Sun Mar 18 23:33:09 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=100,ps3=20,ps4=100,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 697.795
Right Arm Q1 momentum : 0.927999
Right Arm Q1 gauss meter : -0.017448
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 399.457
Right Arm Q2 momentum : 0.928178
Right Arm Q2 gauss meter : 0.2099
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 317.363
Right Arm D1 momentum : 0.9279
Right Arm D1 NMR : 0.344333
Right Arm Q3 power supply current : 369.315
Right Arm Q3 momentum : 0.928141
Right Arm Q3 gauss meter : 0.16547
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1421.98
Left Arm Q1 momentum : 1.8901
Left Arm Q1 gauss meter : 0.12089
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 814.094
Left Arm Q2 momentum : 1.8906
Left Arm Q2 gauss meter : -0.429
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 639.09
Left Arm D1 momentum : 1.89001
Left Arm D1 NMR : 0.699392
Left Arm Q3 power supply current : 752.412
Left Arm Q3 momentum : 1.88992
Left Arm Q3 gauss meter : 0.3758
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 18.4636
Current on Unser monitor : 25.769
Current on Upstream bcm : 18.5271
Current on Downstream bcm : 18.4002
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 91.3686
Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
Radiator 5V Linear Supply : 4.85959
Radiator Encoder : 0.161172
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.38
haSC200_6_Sensor_2_R : 26.93
haSC200_6_Sensor_3_R : 39.1
haSC200_6_Sensor_4_R : 41.03
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.64
haITC502_1_Sensor_2_R : 82.97
haITC502_1_Sensor_3_R : 76.59
haITC502_4_Sensor_1_R : 84.1
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 91.09
haITC502_5_Sensor_2_R : 82.36
haITC502_5_Sensor_3_R : 266.1
haITC502_6_Sensor_1_R : 0
haITC502_6_Sensor_2_R : 0
haITC502_6_Sensor_3_R : 0
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1592
HacR_VPM_LVDT:VALr : 510
HacR_HPE1313A:0_Ch58 : -0.526855
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.914551
HacR_alignROLL : -0.434894
HacR_alignPITCH : -0.0279987
HacR_alignHPT : -1.02765
HacL_HPM_LVDT:VALr : -7704
HacL_VPM_LVDT:VALr : 1894
HacL_HPE1313A:0_Ch58 : -0.208496
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : 0.0722656
HacL_alignROLL : 0.410325
HacL_alignPITCH : -0.0784802
HacL_alignHPT : 4.67814
Right Arm Angle Floor Angle : 45.5
Right Arm Angle Vernier : 0.5
Right Arm Scattering Angle : 45.7068
Left Arm Angle Floor Angle : 13.5
Left Arm Angle Vernier : 46
Left Arm Scattering Angle : 13.5544
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 182
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88