User name adev
Log entry time 09:04:25 on March 28, 2001
Entry number 59459
keyword=Start_Run_3160_RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=production_kin21,mode=coincidence,Lmom=2.521,Rmom=-1.224,Ene=4.232,Angle_R=34.912,Angle_L=12.530
Beginning-of-run EPICS data for Run Number 3160 at Wed Mar 28 09:04:11 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1100,ps2=3500,ps3=35500,ps4=9500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 920.29
Right Arm Q1 momentum : 1.2239
Right Arm Q1 gauss meter : -0.022969
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 526.716
Right Arm Q2 momentum : 1.22387
Right Arm Q2 gauss meter : 0.2769
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 419.671
Right Arm D1 momentum : 1.224
Right Arm D1 NMR : 0.454213
Right Arm Q3 power supply current : 486.847
Right Arm Q3 momentum : 1.22351
Right Arm Q3 gauss meter : 0.2183
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1896.65
Left Arm Q1 momentum : 2.52103
Left Arm Q1 gauss meter : 0.16099
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1085.6
Left Arm Q2 momentum : 2.52112
Left Arm Q2 gauss meter : -0.5717
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 869.59
Left Arm D1 momentum : 2.521
Left Arm D1 NMR : 0.933099
Left Arm Q3 power supply current : 1003.66
Left Arm Q3 momentum : 2.521
Left Arm Q3 gauss meter : 0.501
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 89.7706
Current on Unser monitor : 95.8335
Current on Upstream bcm : 89.7034
Current on Downstream bcm : 89.8378
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 132.331
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.04029
Radiator Encoder : 0.161172
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 19.5
haL2_Fan_frequency_R : 69.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.48
haSC200_6_Sensor_2_R : 28.23
haSC200_6_Sensor_3_R : 40.1
haSC200_6_Sensor_4_R : 40.94
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 82.5
haITC502_1_Sensor_2_R : 82.49
haITC502_1_Sensor_3_R : 84.77
haITC502_4_Sensor_1_R : 86.3
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 83.29
haITC502_5_Sensor_2_R : 82.64
haITC502_5_Sensor_3_R : 261.2
haITC502_6_Sensor_1_R : 82.78
haITC502_6_Sensor_2_R : 83.05
haITC502_6_Sensor_3_R : 28.16
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616895
HacR_HPM_LVDT:VALr : -860
HacR_VPM_LVDT:VALr : 410
HacR_HPE1313A:0_Ch58 : -0.528809
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.869141
HacR_alignROLL : -0.388938
HacR_alignPITCH : -0.0258878
HacR_alignHPT : -1.84783
HacL_HPM_LVDT:VALr : -7298
HacL_VPM_LVDT:VALr : 1549
HacL_HPE1313A:0_Ch58 : -0.22168
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : 0.0874023
HacL_alignROLL : 0.425431
HacL_alignPITCH : -0.0664754
HacL_alignHPT : 4.21724
Right Arm Angle Floor Angle : 34.5
Right Arm Angle Vernier : 35.2
Right Arm Scattering Angle : 34.9124
Left Arm Angle Floor Angle : 12.53
Left Arm Angle Vernier : 36
Left Arm Scattering Angle : 12.5299
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 347
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88