User name adev
Log entry time 01:26:10 on March 29, 2001
Entry number 59507
keyword=Start_Run_3180_RunType=Optics,Tar=9foil-12C,Rad=out,comment=optics_kin22,mode=singles,Lmom=2.542,Rmom=-1.120,Ene=4.232,Angle_R=40.775,Angle_L=12.530
Beginning-of-run EPICS data for Run Number 3180 at Thu Mar 29 01:25:56 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=500,ps3=6,ps4=300,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 842.135
Right Arm Q1 momentum : 1.11996
Right Arm Q1 gauss meter : -0.02106
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 482.056
Right Arm Q2 momentum : 1.1201
Right Arm Q2 gauss meter : 0.2533
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 382.935
Right Arm D1 momentum : 1.12
Right Arm D1 NMR : 0.415618
Right Arm Q3 power supply current : 445.423
Right Arm Q3 momentum : 1.1194
Right Arm Q3 gauss meter : 0.19962
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1912.51
Left Arm Q1 momentum : 2.5421
Left Arm Q1 gauss meter : 0.16224
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1094.82
Left Arm Q2 momentum : 2.54256
Left Arm Q2 gauss meter : -0.5765
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 877.541
Left Arm D1 momentum : 2.54201
Left Arm D1 NMR : 0.940898
Left Arm Q3 power supply current : 1012.03
Left Arm Q3 momentum : 2.54203
Left Arm Q3 gauss meter : 0.5052
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 5.28821
Current on Unser monitor : 12.3137
Current on Upstream bcm : 5.277
Current on Downstream bcm : 5.29941
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 43.0182
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.04029
Radiator Encoder : 0.163614
haBDSPOS : 1.72635e+06
haL1_Fan_frequency_R : 19.5
haL2_Fan_frequency_R : 63.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.59
haSC200_6_Sensor_2_R : 28.31
haSC200_6_Sensor_3_R : 40.28
haSC200_6_Sensor_4_R : 41.11
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 82.95
haITC502_1_Sensor_2_R : 82.92
haITC502_1_Sensor_3_R : 85.29
haITC502_4_Sensor_1_R : 0
haITC502_4_Sensor_2_R : 0
haITC502_4_Sensor_3_R : 0
haITC502_5_Sensor_1_R : 83.68
haITC502_5_Sensor_2_R : 83.09
haITC502_5_Sensor_3_R : 265
haITC502_6_Sensor_1_R : 83.21
haITC502_6_Sensor_2_R : 83.52
haITC502_6_Sensor_3_R : 28.33
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -4397
HacR_VPM_LVDT:VALr : 456
HacR_HPE1313A:0_Ch58 : -0.526855
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.928711
HacR_alignROLL : -0.450009
HacR_alignPITCH : -0.0268522
HacR_alignHPT : 2.14621
HacL_HPM_LVDT:VALr : -7323
HacL_VPM_LVDT:VALr : 1625
HacL_HPE1313A:0_Ch58 : -0.222168
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : 0.0947266
HacL_alignROLL : 0.431472
HacL_alignPITCH : -0.0664754
HacL_alignHPT : 4.24228
Right Arm Angle Floor Angle : 40.5
Right Arm Angle Vernier : 16
Right Arm Scattering Angle : 40.7747
Left Arm Angle Floor Angle : 12.53
Left Arm Angle Vernier : 36
Left Arm Scattering Angle : 12.5298
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 230
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88