User name adev
Log entry time 02:01:19 on March 30, 2001
Entry number 59564
keyword=Start_Run_3203_RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=production_kin22,mode=coincidence,Lmom=2.542,Rmom=-1.120,Ene=4.232,Angle_R=40.775,Angle_L=12.530
Beginning-of-run EPICS data for Run Number 3203 at Fri Mar 30 02:01:01 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1100,ps2=3500,ps3=35500,ps4=9500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 842.1
Right Arm Q1 momentum : 1.11991
Right Arm Q1 gauss meter : -0.021059
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 481.978
Right Arm Q2 momentum : 1.1196
Right Arm Q2 gauss meter : 0.2534
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 382.938
Right Arm D1 momentum : 1.12
Right Arm D1 NMR : 0.415618
Right Arm Q3 power supply current : 445.391
Right Arm Q3 momentum : 1.11933
Right Arm Q3 gauss meter : 0.19961
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1912.4
Left Arm Q1 momentum : 2.54196
Left Arm Q1 gauss meter : 0.16223
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1094.66
Left Arm Q2 momentum : 2.54218
Left Arm Q2 gauss meter : -0.5765
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 877.532
Left Arm D1 momentum : 2.542
Left Arm D1 NMR : 0.940891
Left Arm Q3 power supply current : 1012.06
Left Arm Q3 momentum : 2.54195
Left Arm Q3 gauss meter : 0.5051
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 89.8259
Current on Unser monitor : 96.6934
Current on Upstream bcm : 89.9078
Current on Downstream bcm : 89.7441
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 137.455
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.00366
Radiator Encoder : 0.161172
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 19.5
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.56
haSC200_6_Sensor_2_R : 28.21
haSC200_6_Sensor_3_R : 40.43
haSC200_6_Sensor_4_R : 41.24
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 82.72
haITC502_1_Sensor_2_R : 82.68
haITC502_1_Sensor_3_R : 85.04
haITC502_4_Sensor_1_R : 0
haITC502_4_Sensor_2_R : 0
haITC502_4_Sensor_3_R : 0
haITC502_5_Sensor_1_R : 83.48
haITC502_5_Sensor_2_R : 82.85
haITC502_5_Sensor_3_R : 260.9
haITC502_6_Sensor_1_R : 83.04
haITC502_6_Sensor_2_R : 83.39
haITC502_6_Sensor_3_R : 28.14
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4388
HacR_VPM_LVDT:VALr : 457
HacR_HPE1313A:0_Ch58 : -0.526855
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.935059
HacR_alignROLL : -0.454501
HacR_alignPITCH : -0.0281321
HacR_alignHPT : 2.13869
HacL_HPM_LVDT:VALr : -7311
HacL_VPM_LVDT:VALr : 1625
HacL_HPE1313A:0_Ch58 : -0.222168
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : 0.0942383
HacL_alignROLL : 0.430622
HacL_alignPITCH : -0.0661117
HacL_alignHPT : 4.22816
Right Arm Angle Floor Angle : 40.5
Right Arm Angle Vernier : 16
Right Arm Scattering Angle : 40.7747
Left Arm Angle Floor Angle : 12.53
Left Arm Angle Vernier : 36
Left Arm Scattering Angle : 12.5299
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 416
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88