    User name adev

    Log entry time 10:09:51 on March 30, 2001

    Entry number 59582

    keyword=End_of_Run_3210
    ****************************
     Run Number: 3210
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=production_kin22,mode=coincidence,Lmom=2.542,Rmom=-1.120,Ene=4.232,Angle_R=40.775,Angle_L=12.530
    
    Time of run = 4.6612305 min
    Av. current (on 3x) = 94.326309 uA
    Av. current (on 1x) = 94.118209 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   26.3224  |   26.3806  |   22.0766
    up-down    (mC)|   -0.2280  |   -0.0857  |   -0.6033
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 9831.3847 Hz  |    104227.4 /mC  |    8.938 Hz  |   2749581  |  1100   |    104457.8 /mC
        2      | 43973.582 Hz  |    466185.8 /mC  |   12.564 Hz  |  12298260  |  3500   |    467216.5 /mC
        3      | 241287.62 Hz  |   2558009.7 /mC  |    6.797 Hz  |  67481832  | 35500   |   2563665.6 /mC
        4      | 100458.2 Hz  |   1065007.2 /mC  |   10.575 Hz  |  28095529  |  9500   |   1067362.0 /mC
        5      | 234.47314 Hz  |      2485.8 /mC  |  234.473 Hz  |     65576  |     1   |      2491.3 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 224.297 Hz  |      2377.9 /mC  |  224.297 Hz  | 62730.0  |     1   |      2383.1 /mC
        8    | 1024.0 Hz  |     10855.9 /mC  |    0.016 Hz  |    286386  | 65535   |     10879.9 /mC
        output                       266.457 Hz
    Av. deadtime from accepted triggers = 0.0245
    Av. deadtime from gated scalers = 0.0371
    Accepted triggers  =  74521.00000
    Rate of Left Arm Pulser for electronic DT  = 10.17614
    Rate of Right Arm Pulser for electronic DT  = 10.272681
    Rate of Left Arm Pulser&trig for electronic DT  = 10.033116
    Rate of Right Arm Pulser&trig for electronic DT  = 10.272681
    Left Arm Electronic DT  = 0.014054814
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 457087.52
    Rate of Right Arm Strobe  = 58485.276
        Signal     |    Charge   (C)   
       upstream    |    0.0262084     
       upstream 3x |    0.0263378     
       upstream 10x|    0.0217749     
      downstream   |    0.0264364   
     downstream 3x |    0.0264235   
     downstream 10x|    0.0223782    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3210 at Fri Mar 30 10:09:35 EST 2001
    Right Arm D1 momentum                    : 1.12
    Right Arm arm angle                      : 40.7748
    Left Arm D1 momentum                      : 2.542
    Left Arm arm angle                        : 12.5299
    Tiefenbach Hall A energy                : 4236.98
    Right Arm arm mispointing (HPT)          : 2.13503
    Left Arm arm mispointing (HPT)            : 4.2231
    Right Arm Q1 power supply current        : 842.205
    Right Arm Q1 momentum                    : 1.12005
    Right Arm Q1 gauss meter                 : -0.021059
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 481.98
    Right Arm Q2 momentum                    : 1.11993
    Right Arm Q2 gauss meter                 : 0.2533
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 382.937
    Right Arm D1 momentum                    : 1.12
    Right Arm D1 NMR                         : 0.415618
    Right Arm Q3 power supply current        : 445.655
    Right Arm Q3 momentum                    : 1.11999
    Right Arm Q3 gauss meter                 : 0.19966
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1912.47
    Left Arm Q1 momentum                      : 2.54206
    Left Arm Q1 gauss meter                   : 0.16225
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1094.35
    Left Arm Q2 momentum                      : 2.54146
    Left Arm Q2 gauss meter                   : -0.5764
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 877.537
    Left Arm D1 momentum                      : 2.542
    Left Arm D1 NMR                           : 0.940892
    Left Arm Q3 power supply current          : 1011.94
    Left Arm Q3 momentum                      : 2.54179
    Left Arm Q3 gauss meter                   : 0.5052
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.0389137
    Current on Unser monitor                : 7.45565
    Current on Upstream bcm                 : 0.0453984
    Current on Downstream bcm               : 0.032536
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 47.7905
    MBSY1c Hall A Beam energy               : 4245.79
    MBSY1c magnet current (amp)             : 176.993
    MBSY1c Bdl                              : 1.05954e+06
    MBSY3c Hall C Beam energy               : 885.654
    Tiefenbach Hall A energy                : 4236.98
    Tiefenbach Hall C energy                : 884.263
    Delta(E)/E width (MV_AI_DXWID)          : 8.51098
    IPM1C12.XPOS                            : 0
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0
    IPM1H04B.XPOS                           : 0
    IPM1H04B.YPOS                           : 0
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -4386
     HacR_VPM_LVDT:VALr                     : 480
     HacR_HPE1313A:0_Ch58                   : -0.527344
     HacR_HPE1313A:0_Ch55                   : 22.6562
     HacR_HPE1313A:0_Ch54                   : -0.936523
     HacR_alignROLL                         : -0.456363
     HacR_alignPITCH                        : -0.0278166
     HacR_alignHPT                          : 2.13752
     HacL_HPM_LVDT:VALr                     : -7304
     HacL_VPM_LVDT:VALr                     : 1643
     HacL_HPE1313A:0_Ch58                   : -0.223145
     HacL_HPE1313A:0_Ch55                   : 23.4863
     HacL_HPE1313A:0_Ch54                   : 0.0932617
     HacL_alignROLL                         : 0.430157
     HacL_alignPITCH                        : -0.0656751
     HacL_alignHPT                          : 4.22168
    haBDSPOS                                 : 4.23625e+06
    haL1_Fan_frequency_R                     : 19.5
    haL2_Fan_frequency_R                     : 72
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 20.21
    haH2_P_Exhaust_R                         : 20.55
    haH2_P_Fill_Bottle_R                     : 20.32
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.52
    haD2_P_Fill_Bottle_R                     : 38.55
    haD2_DP_Fill_Exhaust_R                   : 0.0744
    haSC200_6_Sensor_1_R                     : 241.51
    haSC200_6_Sensor_2_R                     : 28.11
    haSC200_6_Sensor_3_R                     : 40.46
    haSC200_6_Sensor_4_R                     : 41.38
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 82.64
    haITC502_1_Sensor_2_R                    : 82.64
    haITC502_1_Sensor_3_R                    : 85
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.02
    haITC502_4_Sensor_1_R                    : 87.1
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 83.43
    haITC502_5_Sensor_2_R                    : 82.8
    haITC502_5_Sensor_3_R                    : 260.7
    haITC502_6_Sensor_1_R                    : 82.97
    haITC502_6_Sensor_2_R                    : 83.3
    haITC502_6_Sensor_3_R                    : 28.06
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 61.2233
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1382.7
    Wien field                               : 40.224
    Laser attenuation Hall A                 : 120
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON