User name adev
Log entry time 04:36:28 on March 31, 2001
Entry number 59629
keyword=End_of_Run_3225
****************************
Run Number: 3225
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin25,mode=coincidence,Lmom=2.266,Rmom=-1.333,Ene=4.232,Angle_R=37.28,Angle_L=14.61
Time of run = 82.774902 min
Av. current (on 3x) = 87.146021 uA
Av. current (on 1x) = 86.958585 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 431.8793 | 432.8102 | 31.5938
up-down (mC)| -3.7391 | -1.3236 | -15.2577
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 6764.535 Hz | 77623.0 /mC | 6764.535 Hz | 33596023 | 1 | 77790.3 /mC
2 | 43599.229 Hz | 500300.9 /mC | 87.198 Hz | 216535320 | 500 | 501379.2 /mC
3 | 239830.44 Hz | 2752052.7 /mC | 19985.870 Hz | 1191116500 | 12 | 2757984.7 /mC
4 | 86987.76 Hz | 998184.0 /mC | 173.976 Hz | 432024200 | 500 | 1000335.5 /mC
5 | 170.16531 Hz | 1952.6 /mC | 170.165 Hz | 845125 | 1 | 1956.9 /mC
Trigger 5 corrected for pulser:
5 (phys) | 159.99254 Hz | 1835.9 /mC | 159.993 Hz | 794602.0 | 1 | 1839.9 /mC
8 | 1024.0 Hz | 11750.4 /mC | 0.016 Hz | 5085690 | 65535 | 11775.7 /mC
output 200.958 Hz
Av. deadtime from accepted triggers = 0.9926
Av. deadtime from gated scalers = 0.4405
Accepted triggers = 998055.00000
Rate of Left Arm Pulser for electronic DT = 10.17277
Rate of Right Arm Pulser for electronic DT = 10.178005
Rate of Left Arm Pulser&trig for electronic DT = 10.032228
Rate of Right Arm Pulser&trig for electronic DT = 10.177602
Left Arm Electronic DT = 0.01381549
Right Arm Electronic DT = 3.956557e-05
Rate of Left Strobe = -427089.28
Rate of Right Arm Strobe = 53740.563
Signal | Charge (C)
upstream | 0.4300097
upstream 3x | 0.4321484
upstream 10x| 0.0239649
downstream | 0.4337488
downstream 3x | 0.4334720
downstream 10x| 0.0392226
****************************
End-of-run EPICS data for Run Number 3225 at Sat Mar 31 04:36:14 EST 2001
Right Arm D1 momentum : 1.333
Right Arm arm angle : 37.2807
Left Arm D1 momentum : 2.266
Left Arm arm angle : 14.6132
Tiefenbach Hall A energy : 4236.99
Right Arm arm mispointing (HPT) : -1.29483
Left Arm arm mispointing (HPT) : 5.41075
Right Arm Q1 power supply current : 1002.29
Right Arm Q1 momentum : 1.33295
Right Arm Q1 gauss meter : -0.025009
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 573.663
Right Arm Q2 momentum : 1.33296
Right Arm Q2 gauss meter : 0.3016
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 457.438
Right Arm D1 momentum : 1.333
Right Arm D1 NMR : 0.49466
Right Arm Q3 power supply current : 530.476
Right Arm Q3 momentum : 1.33316
Right Arm Q3 gauss meter : 0.2378
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1704.71
Left Arm Q1 momentum : 2.2659
Left Arm Q1 gauss meter : 0.14478
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 975.813
Left Arm Q2 momentum : 2.26617
Left Arm Q2 gauss meter : -0.5141
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 774.641
Left Arm D1 momentum : 2.266
Left Arm D1 NMR : 0.83848
Left Arm Q3 power supply current : 902.035
Left Arm Q3 momentum : 2.26574
Left Arm Q3 gauss meter : 0.4504
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 88.4562
Current on Unser monitor : 96.5932
Current on Upstream bcm : 88.5418
Current on Downstream bcm : 88.3707
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 153.51
MBSY1c Hall A Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
MBSY1c Bdl : 1.05954e+06
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 4236.99
Tiefenbach Hall C energy : 884.222
Delta(E)/E width (MV_AI_DXWID) : 8.43136
IPM1C12.XPOS : -0.00594985
IPM1H04A.XPOS : 0.892513
IPM1H04A.YPOS : 0.0732116
IPM1H04B.XPOS : -0.037187
IPM1H04B.YPOS : -0.058778
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1336
HacR_VPM_LVDT:VALr : 490
HacR_HPE1313A:0_Ch58 : -0.527832
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.906738
HacR_alignROLL : -0.426896
HacR_alignPITCH : -0.0267855
HacR_alignHPT : -1.29449
HacL_HPM_LVDT:VALr : -8342
HacL_VPM_LVDT:VALr : 2020
HacL_HPE1313A:0_Ch58 : -0.186523
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : 0.0263672
HacL_alignROLL : 0.366489
HacL_alignPITCH : -0.0979835
HacL_alignHPT : 5.41094
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 19.5
haL2_Fan_frequency_R : 69.5
haL3_Fan_frequency_R : 25
haH2_P_Fill_Target_R : 19.77
haH2_P_Exhaust_R : 20.11
haH2_P_Fill_Bottle_R : 19.78
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.25
haD2_P_Fill_Bottle_R : 37.98
haD2_DP_Fill_Exhaust_R : 0.0745
haSC200_6_Sensor_1_R : 241.69
haSC200_6_Sensor_2_R : 28.33
haSC200_6_Sensor_3_R : 40.71
haSC200_6_Sensor_4_R : 41.48
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.59
haITC502_1_Sensor_2_R : 83.56
haITC502_1_Sensor_3_R : 85.8
haITC502_2_Sensor_1_R : 18.99
haITC502_2_Sensor_2_R : 18.99
haITC502_2_Sensor_3_R : 19.23
haITC502_4_Sensor_1_R : 87.9
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 84.29
haITC502_5_Sensor_2_R : 83.72
haITC502_5_Sensor_3_R : 260.6
haITC502_6_Sensor_1_R : 83.82
haITC502_6_Sensor_2_R : 84.1
haITC502_6_Sensor_3_R : 28.12
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.617041
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 416
Laser power Hall A : 57
Half-wave plate (off=out) : OFF