• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 22:12:21 on March 31, 2001

    Entry number 59664

    keyword=End_of_Run_3239
    ****************************
     Run Number: 3239
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin25,mode=coincidence,Lmom=2.266,Rmom=-1.333,Ene=4.232,Angle_R=37.28,Angle_L=14.61
    
    Time of run = 81.269955 min
    Av. current (on 3x) = 88.87366 uA
    Av. current (on 1x) = 88.683101 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  432.4363  |  433.3655  |   32.5629
    up-down    (mC)|   -3.7208  |   -1.2863  |  -15.3010
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 6899.8795 Hz  |     77636.9 /mC  | 6899.880 Hz  |  33645174  |     1   |     77803.8 /mC
        2      | 44817.682 Hz  |    504285.3 /mC  |   89.635 Hz  | 218539860  |   500   |    505368.9 /mC
        3      | 244607.53 Hz  |   2752306.3 /mC  | 20383.961 Hz  | 1192754600  |    12   |   2758220.3 /mC
        4      | 89242.49 Hz  |   1004150.1 /mC  |  178.485 Hz  | 435163990  |   500   |   1006307.7 /mC
        5      | 173.12261 Hz  |      1948.0 /mC  |  173.123 Hz  |    844180  |     1   |      1952.1 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 162.94972 Hz  |      1833.5 /mC  |  162.950 Hz  | 794575.0  |     1   |      1837.4 /mC
        8    | 1024.0 Hz  |     11522.0 /mC  |    0.016 Hz  |   4993226  | 65535   |     11546.7 /mC
        output                       204.827 Hz
    Av. deadtime from accepted triggers = 0.9926
    Av. deadtime from gated scalers = 0.4246
    Accepted triggers  = 998775.00000
    Rate of Left Arm Pulser for electronic DT  = 10.172886
    Rate of Right Arm Pulser for electronic DT  = 10.189087
    Rate of Left Arm Pulser&trig for electronic DT  = 10.033228
    Rate of Right Arm Pulser&trig for electronic DT  = 10.189087
    Left Arm Electronic DT  = 0.013728455
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = -431648.49
    Rate of Right Arm Strobe  = 55148.65
        Signal     |    Charge   (C)   
       upstream    |    0.4305759     
       upstream 3x |    0.4327224     
       upstream 10x|    0.0249124     
      downstream   |    0.4342967   
     downstream 3x |    0.4340087   
     downstream 10x|    0.0402134    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3239 at Sat Mar 31 22:12:08 EST 2001
    Right Arm D1 momentum                    : 1.333
    Right Arm arm angle                      : 37.2807
    Left Arm D1 momentum                      : 2.266
    Left Arm arm angle                        : 14.6131
    Tiefenbach Hall A energy                : 4237
    Right Arm arm mispointing (HPT)          : -1.29565
    Left Arm arm mispointing (HPT)            : 5.4179
    Right Arm Q1 power supply current        : 1002.19
    Right Arm Q1 momentum                    : 1.33281
    Right Arm Q1 gauss meter                 : -0.025005
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 573.592
    Right Arm Q2 momentum                    : 1.3328
    Right Arm Q2 gauss meter                 : 0.3015
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 457.438
    Right Arm D1 momentum                    : 1.333
    Right Arm D1 NMR                         : 0.49466
    Right Arm Q3 power supply current        : 530.464
    Right Arm Q3 momentum                    : 1.33313
    Right Arm Q3 gauss meter                 : 0.2378
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1704.81
    Left Arm Q1 momentum                      : 2.26604
    Left Arm Q1 gauss meter                   : 0.14478
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 975.774
    Left Arm Q2 momentum                      : 2.26608
    Left Arm Q2 gauss meter                   : -0.5141
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 774.644
    Left Arm D1 momentum                      : 2.266
    Left Arm D1 NMR                           : 0.838481
    Left Arm Q3 power supply current          : 902.133
    Left Arm Q3 momentum                      : 2.26572
    Left Arm Q3 gauss meter                   : 0.4504
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 89.4405
    Current on Unser monitor                : 97.088
    Current on Upstream bcm                 : 89.3836
    Current on Downstream bcm               : 89.4973
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 156.67
    MBSY1c Hall A Beam energy               : 4245.79
    MBSY1c magnet current (amp)             : 176.993
    MBSY1c Bdl                              : 1.05954e+06
    MBSY3c Hall C Beam energy               : 885.654
    Tiefenbach Hall A energy                : 4237
    Tiefenbach Hall C energy                : 883.969
    Delta(E)/E width (MV_AI_DXWID)          : 8.47925
    IPM1C12.XPOS                            : 0.00112659
    IPM1H04A.XPOS                           : 0.891312
    IPM1H04A.YPOS                           : 0.0980736
    IPM1H04B.XPOS                           : -0.0354287
    IPM1H04B.YPOS                           : -0.0293305
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -1335
     HacR_VPM_LVDT:VALr                     : 489
     HacR_HPE1313A:0_Ch58                   : -0.527832
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.904785
     HacR_alignROLL                         : -0.425305
     HacR_alignPITCH                        : -0.0269189
     HacR_alignHPT                          : -1.2954
     HacL_HPM_LVDT:VALr                     : -8348
     HacL_VPM_LVDT:VALr                     : 2012
     HacL_HPE1313A:0_Ch58                   : -0.187012
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : 0.0263672
     HacL_alignROLL                         : 0.366412
     HacL_alignPITCH                        : -0.0974733
     HacL_alignHPT                          : 5.41879
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 19.5
    haL2_Fan_frequency_R                     : 76
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 19.77
    haH2_P_Exhaust_R                         : 20.07
    haH2_P_Fill_Bottle_R                     : 19.8
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.12
    haD2_P_Fill_Bottle_R                     : 37.71
    haD2_DP_Fill_Exhaust_R                   : 0.0746
    haSC200_6_Sensor_1_R                     : 241.44
    haSC200_6_Sensor_2_R                     : 28.08
    haSC200_6_Sensor_3_R                     : 40.58
    haSC200_6_Sensor_4_R                     : 41.31
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.18
    haITC502_1_Sensor_2_R                    : 83.15
    haITC502_1_Sensor_3_R                    : 85.44
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.25
    haITC502_4_Sensor_1_R                    : 87.5
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 83.91
    haITC502_5_Sensor_2_R                    : 83.31
    haITC502_5_Sensor_3_R                    : 260.4
    haITC502_6_Sensor_1_R                    : 83.4
    haITC502_6_Sensor_2_R                    : 83.67
    haITC502_6_Sensor_3_R                    : 28.12
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 61.2233
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1382.7
    Wien field                               : 40.224
    Laser attenuation Hall A                 : 463
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF