User name adev
Log entry time 21:11:27 on April 1, 2001
Entry number 59702
keyword=End_of_Run_3253
****************************
Run Number: 3253
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin25,mode=coincidence,Lmom=2.266,Rmom=-1.333,Ene=4.232,Angle_R=37.28,Angle_L=14.61
junk
Time of run = 6.0944987 min
Av. current (on 3x) = 69.062558 uA
Av. current (on 1x) = 68.9075 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 25.1974 | 25.2541 | 22.5235
up-down (mC)| -0.2252 | -0.0901 | -0.5089
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 2147.0812 Hz | 31088.9 /mC | 2147.081 Hz | 785123 | 1 | 31158.9 /mC
2 | 13672.99 Hz | 197979.8 /mC | 27.346 Hz | 4999801 | 500 | 198425.3 /mC
3 | 191447.4 Hz | 2772086.8 /mC | 15953.950 Hz | 70006556 | 12 | 2778324.6 /mC
4 | 70920.868 Hz | 1026907.6 /mC | 141.842 Hz | 25933628 | 500 | 1029218.4 /mC
5 | 53.633069 Hz | 776.6 /mC | 53.633 Hz | 19612 | 1 | 778.3 /mC
Trigger 5 corrected for pulser:
5 (phys) | 43.468164 Hz | 629.4 /mC | 43.468 Hz | 15895.0 | 1 | 630.8 /mC
8 | 1024.0 Hz | 14827.1 /mC | 0.016 Hz | 374446 | 65535 | 14860.5 /mC
output 71.551 Hz
Av. deadtime from accepted triggers = 0.9961
Av. deadtime from gated scalers = 0.0113
Accepted triggers = 26164.00000
Rate of Left Arm Pulser for electronic DT = 10.164905
Rate of Right Arm Pulser for electronic DT = 10.159436
Rate of Left Arm Pulser&trig for electronic DT = 10.052782
Rate of Right Arm Pulser&trig for electronic DT = 10.159436
Left Arm Electronic DT = 0.011030401
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 352863.24
Rate of Right Arm Strobe = 17242.58
Signal | Charge (C)
upstream | 0.0250848
upstream 3x | 0.0252091
upstream 10x| 0.0222690
downstream | 0.0253100
downstream 3x | 0.0252992
downstream 10x| 0.0227779
****************************
End-of-run EPICS data for Run Number 3253 at Sun Apr 1 21:11:16 EDT 2001
Right Arm D1 momentum : 1.333
Right Arm arm angle : 37.2806
Left Arm D1 momentum : 2.266
Left Arm arm angle : 14.6131
Tiefenbach Hall A energy : 4236.99
Right Arm arm mispointing (HPT) : -1.28669
Left Arm arm mispointing (HPT) : 5.42636
Right Arm Q1 power supply current : 1002.19
Right Arm Q1 momentum : 1.33281
Right Arm Q1 gauss meter : -0.025007
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 573.674
Right Arm Q2 momentum : 1.33299
Right Arm Q2 gauss meter : 0.3015
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 457.43
Right Arm D1 momentum : 1.333
Right Arm D1 NMR : 0.49466
Right Arm Q3 power supply current : 530.373
Right Arm Q3 momentum : 1.3329
Right Arm Q3 gauss meter : 0.2377
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1704.71
Left Arm Q1 momentum : 2.2659
Left Arm Q1 gauss meter : 0.14481
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 975.825
Left Arm Q2 momentum : 2.2662
Left Arm Q2 gauss meter : -0.514
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 774.638
Left Arm D1 momentum : 2.266
Left Arm D1 NMR : 0.838479
Left Arm Q3 power supply current : 902.1
Left Arm Q3 momentum : 2.26591
Left Arm Q3 gauss meter : 0.4503
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 87.0135
Current on Unser monitor : 94.2042
Current on Upstream bcm : 86.8743
Current on Downstream bcm : 87.0974
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 156.083
MBSY1c Hall A Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
MBSY1c Bdl : 1.05954e+06
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 4236.99
Tiefenbach Hall C energy : 884.207
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.00369728
IPM1H04A.XPOS : 0.887587
IPM1H04A.YPOS : 0.0609844
IPM1H04B.XPOS : -0.0373568
IPM1H04B.YPOS : -0.0627531
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -1343
HacR_VPM_LVDT:VALr : 494
HacR_HPE1313A:0_Ch58 : -0.527344
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.904785
HacR_alignROLL : -0.423882
HacR_alignPITCH : -0.0268522
HacR_alignHPT : -1.28725
HacL_HPM_LVDT:VALr : -8355
HacL_VPM_LVDT:VALr : 2005
HacL_HPE1313A:0_Ch58 : -0.1875
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : 0.0263672
HacL_alignROLL : 0.366025
HacL_alignPITCH : -0.0984201
HacL_alignHPT : 5.4268
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 20
haL2_Fan_frequency_R : 73
haL3_Fan_frequency_R : 25
haH2_P_Fill_Target_R : 19.72
haH2_P_Exhaust_R : 20.11
haH2_P_Fill_Bottle_R : 19.72
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.05
haD2_P_Fill_Bottle_R : 37.68
haD2_DP_Fill_Exhaust_R : 0.0745
haSC200_6_Sensor_1_R : 241.71
haSC200_6_Sensor_2_R : 28.16
haSC200_6_Sensor_3_R : 40.83
haSC200_6_Sensor_4_R : 41.41
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.24
haITC502_1_Sensor_2_R : 83.24
haITC502_1_Sensor_3_R : 85.53
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.24
haITC502_4_Sensor_1_R : 87.6
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 84.02
haITC502_5_Sensor_2_R : 83.39
haITC502_5_Sensor_3_R : 260.3
haITC502_6_Sensor_1_R : 83.48
haITC502_6_Sensor_2_R : 83.83
haITC502_6_Sensor_3_R : 28.1
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.61709
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 363
Laser power Hall A : 57
Half-wave plate (off=out) : OFF