• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 11:23:59 on April 3, 2001

    Entry number 59828

    keyword=End_of_Run_3305
    ****************************
     Run Number: 3305
    End of Run Comment:
    RunType=Pulser,Tar=absence,Rad=out,comment=kin28 ,mode=coincidence,Lmom=2.147,Rmom=-1.526,Ene=4.232,Angle_R=31.16,Angle_L=15.48
    
    Time of run = 0.2180664 min
    Av. current (on 3x) = 0.007642932 uA
    Av. current (on 1x) = -0.007642932 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   -0.0001  |    0.0001  |    0.0003
    up-down    (mC)|    0.0007  |   -0.0001  |    0.0001
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 18.572325 Hz  |   2430000.0 /mC  |    0.017 Hz  |       243  |  1100   |  -2430000.0 /mC
        2      | 2170.7455 Hz  | 284020000.0 /mC  |    0.620 Hz  |     28402  |  3500   | -284020000.0 /mC
        3      | 19.260189 Hz  |   2520000.0 /mC  |    0.001 Hz  |       252  | 35500   |  -2520000.0 /mC
        4      | 2609.3734 Hz  | 341410000.0 /mC  |    0.275 Hz  |     34141  |  9500   | -341410000.0 /mC
        5      | 10.241529 Hz  |   1340000.0 /mC  |   10.242 Hz  |       134  |     1   |  -1340000.0 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.0 Hz  |        -0.0 /mC  |    0.000 Hz  | -1.571536e-06  |     1   |         0.0 /mC
        8    | 1024.0 Hz  | 133980000.0 /mC  |  256.000 Hz  |     13398  |     4   | -133980000.0 /mC
        output                       266.203 Hz
    Av. deadtime from accepted triggers = 0.0035
    Av. deadtime from gated scalers = 0.0357
    Accepted triggers  =   3483.00000
    Rate of Left Arm Pulser for electronic DT  = 10.241529
    Rate of Right Arm Pulser for electronic DT  = 13.375131
    Rate of Left Arm Pulser&trig for electronic DT  = 10.241529
    Rate of Right Arm Pulser&trig for electronic DT  = 13.375131
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 3501.3036
    Rate of Right Arm Strobe  = 2063.5916
        Signal     |    Charge   (C)   
       upstream    |    0.0000003     
       upstream 3x |    -0.0000000     
       upstream 10x|    0.0000003     
      downstream   |    -0.0000004   
     downstream 3x |    0.0000001   
     downstream 10x|    0.0000002    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3305 at Tue Apr  3 11:23:42 EDT 2001
    Right Arm D1 momentum                    : 1.526
    Right Arm arm angle                      : 31.1653
    Left Arm D1 momentum                      : 2.14699
    Left Arm arm angle                        : 15.4807
    Tiefenbach Hall A energy                : 4236.94
    Right Arm arm mispointing (HPT)          : -2.12105
    Left Arm arm mispointing (HPT)            : 5.35792
    Right Arm Q1 power supply current        : 1147.51
    Right Arm Q1 momentum                    : 1.52608
    Right Arm Q1 gauss meter                 : -0.02859
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 656.577
    Right Arm Q2 momentum                    : 1.52562
    Right Arm Q2 gauss meter                 : 0.3451
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 524.601
    Right Arm D1 momentum                    : 1.526
    Right Arm D1 NMR                         : 0.56628
    Right Arm Q3 power supply current        : 607.103
    Right Arm Q3 momentum                    : 1.52573
    Right Arm Q3 gauss meter                 : 0.2723
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1615.15
    Left Arm Q1 momentum                      : 2.14685
    Left Arm Q1 gauss meter                   : 0.13723
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 924.533
    Left Arm Q2 momentum                      : 2.14708
    Left Arm Q2 gauss meter                   : -0.4872
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 731.195
    Left Arm D1 momentum                      : 2.14699
    Left Arm D1 NMR                           : 0.794429
    Left Arm Q3 power supply current          : 854.775
    Left Arm Q3 momentum                      : 2.14704
    Left Arm Q3 gauss meter                   : 0.4267
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.0422215
    Current on Unser monitor                : 7.71336
    Current on Upstream bcm                 : 0.0508974
    Current on Downstream bcm               : 0.0334763
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 1.50159
    MBSY1c Hall A Beam energy               : 4245.79
    MBSY1c magnet current (amp)             : 0.0377197
    MBSY1c Bdl                              : 1.05954e+06
    MBSY3c Hall C Beam energy               : 885.654
    Tiefenbach Hall A energy                : 4236.94
    Tiefenbach Hall C energy                : 884.213
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0
    IPM1H04B.XPOS                           : 0
    IPM1H04B.YPOS                           : 0
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -640
     HacR_VPM_LVDT:VALr                     : 125
     HacR_HPE1313A:0_Ch58                   : -0.542969
     HacR_HPE1313A:0_Ch55                   : 22.7051
     HacR_HPE1313A:0_Ch54                   : -0.780762
     HacR_alignROLL                         : -0.299537
     HacR_alignPITCH                        : -0.0139675
     HacR_alignHPT                          : -2.11853
     HacL_HPM_LVDT:VALr                     : -8289
     HacL_VPM_LVDT:VALr                     : 2076
     HacL_HPE1313A:0_Ch58                   : -0.178223
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : 0.0126953
     HacL_alignROLL                         : 0.353554
     HacL_alignPITCH                        : -0.10548
     HacL_alignHPT                          : 5.35904
    haBDSPOS                                 : -44998
    haL1_Fan_frequency_R                     : 20
    haL2_Fan_frequency_R                     : 64
    haL3_Fan_frequency_R                     : 25
    haH2_P_Fill_Target_R                     : 20.07
    haH2_P_Exhaust_R                         : 20.37
    haH2_P_Fill_Bottle_R                     : 20.11
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.3
    haD2_P_Fill_Bottle_R                     : 38.2
    haD2_DP_Fill_Exhaust_R                   : 0.0743
    haSC200_6_Sensor_1_R                     : 241.91
    haSC200_6_Sensor_2_R                     : 28.46
    haSC200_6_Sensor_3_R                     : 41.18
    haSC200_6_Sensor_4_R                     : 41.61
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 84.62
    haITC502_1_Sensor_2_R                    : 84.58
    haITC502_1_Sensor_3_R                    : 87
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.01
    haITC502_4_Sensor_1_R                    : 88.9
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 85.29
    haITC502_5_Sensor_2_R                    : 84.73
    haITC502_5_Sensor_3_R                    : 266.7
    haITC502_6_Sensor_1_R                    : 84.82
    haITC502_6_Sensor_2_R                    : 85.22
    haITC502_6_Sensor_3_R                    : 28.35
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 61.2233
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1382.7
    Wien field                               : 40.224
    Laser attenuation Hall A                 : 100
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF