User name adev
Log entry time 13:19:46 on April 3, 2001
Entry number 59834
keyword=Start_Run_3321_RunType=Pulser,Tar=absence,Rad=out,comment=kin28
Beginning-of-run EPICS data for Run Number 3321 at Tue Apr 3 13:10:53 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1100,ps2=3500,ps3=35500,ps4=9500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1147.58
Right Arm Q1 momentum : 1.52617
Right Arm Q1 gauss meter : -0.02858
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 656.658
Right Arm Q2 momentum : 1.52581
Right Arm Q2 gauss meter : 0.3452
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 524.603
Right Arm D1 momentum : 1.526
Right Arm D1 NMR : 0.56628
Right Arm Q3 power supply current : 607.122
Right Arm Q3 momentum : 1.52578
Right Arm Q3 gauss meter : 0.2724
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1615.07
Left Arm Q1 momentum : 2.14676
Left Arm Q1 gauss meter : 0.13721
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 924.65
Left Arm Q2 momentum : 2.14735
Left Arm Q2 gauss meter : -0.4872
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 731.201
Left Arm D1 momentum : 2.14699
Left Arm D1 NMR : 0.794429
Left Arm Q3 power supply current : 854.858
Left Arm Q3 momentum : 2.14724
Left Arm Q3 gauss meter : 0.4268
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0437665
Current on Unser monitor : 8.3742
Current on Upstream bcm : 0.0526317
Current on Downstream bcm : 0.0351038
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00143682
Beam energy : 4245.79
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.15873
haBDSPOS : -44998
haL1_Fan_frequency_R : 19.5
haL2_Fan_frequency_R : 72
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.56
haSC200_6_Sensor_2_R : 28.26
haSC200_6_Sensor_3_R : 40.95
haSC200_6_Sensor_4_R : 41.46
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 85.22
haITC502_1_Sensor_2_R : 85.2
haITC502_1_Sensor_3_R : 87.67
haITC502_4_Sensor_1_R : 89.5
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 85.91
haITC502_5_Sensor_2_R : 85.37
haITC502_5_Sensor_3_R : 266.6
haITC502_6_Sensor_1_R : 85.48
haITC502_6_Sensor_2_R : 85.94
haITC502_6_Sensor_3_R : 28.38
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -625
HacR_VPM_LVDT:VALr : 160
HacR_HPE1313A:0_Ch58 : -0.542969
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.780762
HacR_alignROLL : -0.299537
HacR_alignPITCH : -0.0130697
HacR_alignHPT : -2.13644
HacL_HPM_LVDT:VALr : -8287
HacL_VPM_LVDT:VALr : 2125
HacL_HPE1313A:0_Ch58 : -0.174805
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : 0.012207
HacL_alignROLL : 0.35216
HacL_alignPITCH : -0.108972
HacL_alignHPT : 5.35524
Right Arm Angle Floor Angle : 31
Right Arm Angle Vernier : -8
Right Arm Scattering Angle : 31.1654
Left Arm Angle Floor Angle : 15.5
Left Arm Angle Vernier : 34
Left Arm Scattering Angle : 15.4807
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 200
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88