    User name adev

    Log entry time 16:42:25 on April 3, 2001

    Entry number 59872

    keyword=End_of_Run_3335
    ****************************
     Run Number: 3335
    End of Run Comment:
    RunType=Optics,Tar=carbon,Rad=out,comment=kin23,mode=coincidence,Lmom=1.741,Rmom=-1.6880,Ene=4.232,Angle_R=32.991,Angle_L=18.555
    
    
    Time of run = 11.397624 min
    Av. current (on 3x) = 19.547642 uA
    Av. current (on 1x) = 19.488127 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   13.3271  |   13.3678  |   13.3936
    up-down    (mC)|   -0.0975  |   -0.0658  |   -0.0447
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 127.18733 Hz  |      6506.5 /mC  |  127.187 Hz  |     86978  |     1   |      6526.4 /mC
        2      | 3673.273 Hz  |    187913.9 /mC  |    7.347 Hz  |   2511995  |   500   |    188487.7 /mC
        3      | 4177.9659 Hz  |    213732.5 /mC  |  167.119 Hz  |   2857133  |    25   |    214385.2 /mC
        4      | 3454.3136 Hz  |    176712.5 /mC  |    6.909 Hz  |   2362258  |   500   |    177252.2 /mC
        5      | 10.342799 Hz  |       529.1 /mC  |   10.343 Hz  |      7073  |     1   |       530.7 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.165239 Hz  |         8.5 /mC  |    0.165 Hz  | 113.00008  |     1   |         8.5 /mC
        8    | 1024.0 Hz  |     52384.8 /mC  |    0.016 Hz  |    700270  | 65535   |     52544.8 /mC
        output                       297.682 Hz
    Av. deadtime from accepted triggers = 0.0340
    Av. deadtime from gated scalers = 0.0484
    Accepted triggers  = 203572.00000
    Rate of Left Arm Pulser for electronic DT  = 10.17756
    Rate of Right Arm Pulser for electronic DT  = 10.225816
    Rate of Left Arm Pulser&trig for electronic DT  = 10.176098
    Rate of Right Arm Pulser&trig for electronic DT  = 10.225816
    Left Arm Electronic DT  = 0.00014367816
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 10688.39
    Rate of Right Arm Strobe  = 3978.0178
        Signal     |    Charge   (C)   
       upstream    |    0.0132784     
       upstream 3x |    0.0133349     
       upstream 10x|    0.0133713     
      downstream   |    0.0133759   
     downstream 3x |    0.0134007   
     downstream 10x|    0.0134160    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3335 at Tue Apr  3 16:42:10 EDT 2001
    Right Arm D1 momentum                    : 1.688
    Right Arm arm angle                      : 32.991
    Left Arm D1 momentum                      : 1.741
    Left Arm arm angle                        : 18.555
    Tiefenbach Hall A energy                : 4236.99
    Right Arm arm mispointing (HPT)          : -0.17304
    Left Arm arm mispointing (HPT)            : 5.01614
    Right Arm Q1 power supply current        : 1269.24
    Right Arm Q1 momentum                    : 1.68797
    Right Arm Q1 gauss meter                 : -0.0316
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 726.349
    Right Arm Q2 momentum                    : 1.68774
    Right Arm Q2 gauss meter                 : 0.3818
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 581.863
    Right Arm D1 momentum                    : 1.688
    Right Arm D1 NMR                         : 0.626397
    Right Arm Q3 power supply current        : 671.546
    Right Arm Q3 momentum                    : 1.68769
    Right Arm Q3 gauss meter                 : 0.3014
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1309.59
    Left Arm Q1 momentum                      : 1.74072
    Left Arm Q1 gauss meter                   : 0.11149
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 749.496
    Left Arm Q2 momentum                      : 1.74059
    Left Arm Q2 gauss meter                   : -0.3952
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 585.641
    Left Arm D1 momentum                      : 1.741
    Left Arm D1 NMR                           : 0.644289
    Left Arm Q3 power supply current          : 693.095
    Left Arm Q3 momentum                      : 1.7411
    Left Arm Q3 gauss meter                   : 0.3461
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 23.7005
    Current on Unser monitor                : 30.3574
    Current on Upstream bcm                 : 23.6942
    Current on Downstream bcm               : 23.7068
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 23.8947
    MBSY1c Hall A Beam energy               : 4245.79
    MBSY1c magnet current (amp)             : 176.993
    MBSY1c Bdl                              : 1.05954e+06
    MBSY3c Hall C Beam energy               : 885.654
    Tiefenbach Hall A energy                : 4236.99
    Tiefenbach Hall C energy                : 884.195
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.0037016
    IPM1H04A.XPOS                           : 0.910641
    IPM1H04A.YPOS                           : 0.0394739
    IPM1H04B.XPOS                           : 0.0321338
    IPM1H04B.YPOS                           : -0.0336352
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -2376
     HacR_VPM_LVDT:VALr                     : 360
     HacR_HPE1313A:0_Ch58                   : -0.53125
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.788086
     HacR_alignROLL                         : -0.306556
     HacR_alignPITCH                        : -0.024159
     HacR_alignHPT                          : -0.172415
     HacL_HPM_LVDT:VALr                     : -7932
     HacL_VPM_LVDT:VALr                     : 2245
     HacL_HPE1313A:0_Ch58                   : -0.149902
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.111328
     HacL_alignROLL                         : 0.236897
     HacL_alignPITCH                        : -0.110763
     HacL_alignHPT                          : 5.01614
    haBDSPOS                                 : 708449
    haL1_Fan_frequency_R                     : 20
    haL2_Fan_frequency_R                     : 65
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 20.26
    haH2_P_Exhaust_R                         : 20.58
    haH2_P_Fill_Bottle_R                     : 20.32
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.44
    haD2_P_Fill_Bottle_R                     : 38.5
    haD2_DP_Fill_Exhaust_R                   : 0.0745
    haSC200_6_Sensor_1_R                     : 241.84
    haSC200_6_Sensor_2_R                     : 28.51
    haSC200_6_Sensor_3_R                     : 41.13
    haSC200_6_Sensor_4_R                     : 41.58
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 85.75
    haITC502_1_Sensor_2_R                    : 85.73
    haITC502_1_Sensor_3_R                    : 88.24
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19
    haITC502_4_Sensor_1_R                    : 90.1
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 86.39
    haITC502_5_Sensor_2_R                    : 85.88
    haITC502_5_Sensor_3_R                    : 265.9
    haITC502_6_Sensor_1_R                    : 85.91
    haITC502_6_Sensor_2_R                    : 86.31
    haITC502_6_Sensor_3_R                    : 28.26
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 61.2233
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1382.7
    Wien field                               : 40.224
    Laser attenuation Hall A                 : 157
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON