User name adev
Log entry time 16:48:20 on April 3, 2001
Entry number 59873
keyword=Start_Run_3336_RunType=Optics,Tar=dum-15cm,Rad=out,comment=kin23,mode=coincidence,Lmom=1.741,Rmom=-1.6880,Ene=4.232,Angle_R=32.991,Angle_L=18.555
Beginning-of-run EPICS data for Run Number 3336 at Tue Apr 3 16:48:05 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=500,ps3=25,ps4=500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1269.24
Right Arm Q1 momentum : 1.68797
Right Arm Q1 gauss meter : -0.0316
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 726.568
Right Arm Q2 momentum : 1.68825
Right Arm Q2 gauss meter : 0.3818
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 581.858
Right Arm D1 momentum : 1.688
Right Arm D1 NMR : 0.626396
Right Arm Q3 power supply current : 671.6
Right Arm Q3 momentum : 1.68782
Right Arm Q3 gauss meter : 0.3013
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1309.56
Left Arm Q1 momentum : 1.74067
Left Arm Q1 gauss meter : 0.11152
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 749.824
Left Arm Q2 momentum : 1.74135
Left Arm Q2 gauss meter : -0.3952
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 585.639
Left Arm D1 momentum : 1.741
Left Arm D1 NMR : 0.644289
Left Arm Q3 power supply current : 693.083
Left Arm Q3 momentum : 1.74089
Left Arm Q3 gauss meter : 0.3461
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 5.18863
Current on Unser monitor : 11.2876
Current on Upstream bcm : 5.11645
Current on Downstream bcm : 5.26082
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 5.23904
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.01587
Radiator Encoder : 0.141636
haBDSPOS : 1.72635e+06
haL1_Fan_frequency_R : 19.5
haL2_Fan_frequency_R : 69.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.93
haSC200_6_Sensor_2_R : 28.55
haSC200_6_Sensor_3_R : 41.18
haSC200_6_Sensor_4_R : 41.56
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 85.77
haITC502_1_Sensor_2_R : 85.76
haITC502_1_Sensor_3_R : 88.22
haITC502_4_Sensor_1_R : 90
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 86.41
haITC502_5_Sensor_2_R : 85.9
haITC502_5_Sensor_3_R : 264.4
haITC502_6_Sensor_1_R : 85.96
haITC502_6_Sensor_2_R : 86.34
haITC502_6_Sensor_3_R : 28.25
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -2367
HacR_VPM_LVDT:VALr : 365
HacR_HPE1313A:0_Ch58 : -0.53125
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.787598
HacR_alignROLL : -0.306438
HacR_alignPITCH : -0.0238433
HacR_alignHPT : -0.182557
HacL_HPM_LVDT:VALr : -7951
HacL_VPM_LVDT:VALr : 2244
HacL_HPE1313A:0_Ch58 : -0.148926
HacL_HPE1313A:0_Ch55 : 0
HacL_HPE1313A:0_Ch54 : -0.111816
HacL_alignROLL : 0.236529
HacL_alignPITCH : -0.11171
HacL_alignHPT : 5.03867
Right Arm Angle Floor Angle : 32.5
Right Arm Angle Vernier : 50.8
Right Arm Scattering Angle : 32.991
Left Arm Angle Floor Angle : 18.5
Left Arm Angle Vernier : 46.5
Left Arm Scattering Angle : 18.5549
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 171
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88