User name adev
Log entry time 18:51:41 on April 3, 2001
Entry number 59877
keyword=Start_Run_3338_RunType=Optics,Tar=9foil-12C,Rad=out,comment=kin23,mode=coincidence,Lmom=1.741,Rmom=-1.6880,Ene=4.232,Angle_R=32.991,Angle_L=18.555
Beginning-of-run EPICS data for Run Number 3338 at Tue Apr 3 18:51:21 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=500,ps3=25,ps4=500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1269.17
Right Arm Q1 momentum : 1.68787
Right Arm Q1 gauss meter : -0.03159
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 726.507
Right Arm Q2 momentum : 1.68811
Right Arm Q2 gauss meter : 0.3818
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 581.863
Right Arm D1 momentum : 1.688
Right Arm D1 NMR : 0.626397
Right Arm Q3 power supply current : 671.629
Right Arm Q3 momentum : 1.6879
Right Arm Q3 gauss meter : 0.3013
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1309.67
Left Arm Q1 momentum : 1.74081
Left Arm Q1 gauss meter : 0.1115
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 749.723
Left Arm Q2 momentum : 1.74111
Left Arm Q2 gauss meter : -0.3952
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 585.64
Left Arm D1 momentum : 1.741
Left Arm D1 NMR : 0.644288
Left Arm Q3 power supply current : 693.086
Left Arm Q3 momentum : 1.7409
Left Arm Q3 gauss meter : 0.3461
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 22.3671
Current on Unser monitor : 30.2605
Current on Upstream bcm : 22.3123
Current on Downstream bcm : 22.4219
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 60.5601
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.01099
Radiator Encoder : 0.15873
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 20
haL2_Fan_frequency_R : 66.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.68
haSC200_6_Sensor_2_R : 28.39
haSC200_6_Sensor_3_R : 41.01
haSC200_6_Sensor_4_R : 41.48
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 85.86
haITC502_1_Sensor_2_R : 85.84
haITC502_1_Sensor_3_R : 88.3
haITC502_4_Sensor_1_R : 90.2
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 86.53
haITC502_5_Sensor_2_R : 85.99
haITC502_5_Sensor_3_R : 263.7
haITC502_6_Sensor_1_R : 86.04
haITC502_6_Sensor_2_R : 86.42
haITC502_6_Sensor_3_R : 28.1
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -2381
HacR_VPM_LVDT:VALr : 328
HacR_HPE1313A:0_Ch58 : -0.530762
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.789062
HacR_alignROLL : -0.307976
HacR_alignPITCH : -0.0237767
HacR_alignHPT : -0.166009
HacL_HPM_LVDT:VALr : -7913
HacL_VPM_LVDT:VALr : 2223
HacL_HPE1313A:0_Ch58 : -0.149902
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.110352
HacL_alignROLL : 0.237264
HacL_alignPITCH : -0.109816
HacL_alignHPT : 4.99362
Right Arm Angle Floor Angle : 32.5
Right Arm Angle Vernier : 50.8
Right Arm Scattering Angle : 32.9909
Left Arm Angle Floor Angle : 18.5
Left Arm Angle Vernier : 46.5
Left Arm Scattering Angle : 18.5552
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 165
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88