User name adev
Log entry time 02:54:29 on April 4, 2001
Entry number 59898
keyword=End_of_Run_3344
****************************
Run Number: 3344
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin23,mode=coincidence,Lmom=1.741,Rmom=-1.6880,Ene=4.232,Angle_R=32.991,Angle_L=18.555
Time of run = 98.282813 min
Av. current (on 3x) = 82.530621 uA
Av. current (on 1x) = 82.353395 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 485.6354 | 486.6805 | 74.4120
up-down (mC)| -4.2404 | -1.5308 | -16.6079
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 3946.516 Hz | 47818.8 /mC | 7.893 Hz | 23272482 | 500 | 47921.7 /mC
2 | 44611.367 Hz | 540543.2 /mC | 8.922 Hz | 263071840 | 5000 | 541706.5 /mC
3 | 304789.31 Hz | 3693045.2 /mC | 8.586 Hz | 1797333100 | 35500 | 3700992.8 /mC
4 | 79285.544 Hz | 960680.3 /mC | 8.346 Hz | 467544380 | 9500 | 962747.7 /mC
5 | 140.39857 Hz | 1701.2 /mC | 140.399 Hz | 827926 | 1 | 1704.8 /mC
Trigger 5 corrected for pulser:
5 (phys) | 130.22555 Hz | 1577.9 /mC | 130.226 Hz | 767936.0 | 1 | 1581.3 /mC
8 | 1024.0 Hz | 12407.5 /mC | 0.016 Hz | 6038496 | 65535 | 12434.2 /mC
output 169.308 Hz
Av. deadtime from accepted triggers = 0.0263
Av. deadtime from gated scalers = 0.1595
Accepted triggers = 998405.00000
Rate of Left Arm Pulser for electronic DT = 10.173023
Rate of Right Arm Pulser for electronic DT = 10.180824
Rate of Left Arm Pulser&trig for electronic DT = 9.9873345
Rate of Right Arm Pulser&trig for electronic DT = 10.180824
Left Arm Electronic DT = 0.018253042
Right Arm Electronic DT = 0.0
Rate of Left Strobe = -211009.79
Rate of Right Arm Strobe = 49529.281
Signal | Charge (C)
upstream | 0.4835152
upstream 3x | 0.4859151
upstream 10x| 0.0661081
downstream | 0.4877556
downstream 3x | 0.4874459
downstream 10x| 0.0827160
****************************
End-of-run EPICS data for Run Number 3344 at Wed Apr 4 02:54:13 EDT 2001
Right Arm D1 momentum : 1.688
Right Arm arm angle : 32.991
Left Arm D1 momentum : 1.741
Left Arm arm angle : 18.5551
Tiefenbach Hall A energy : 4236.99
Right Arm arm mispointing (HPT) : -0.176431
Left Arm arm mispointing (HPT) : 5.00632
Right Arm Q1 power supply current : 1269.17
Right Arm Q1 momentum : 1.68787
Right Arm Q1 gauss meter : -0.03159
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 726.619
Right Arm Q2 momentum : 1.68837
Right Arm Q2 gauss meter : 0.3818
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 581.864
Right Arm D1 momentum : 1.688
Right Arm D1 NMR : 0.626397
Right Arm Q3 power supply current : 671.447
Right Arm Q3 momentum : 1.68744
Right Arm Q3 gauss meter : 0.3013
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1309.59
Left Arm Q1 momentum : 1.74072
Left Arm Q1 gauss meter : 0.11149
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 749.679
Left Arm Q2 momentum : 1.74101
Left Arm Q2 gauss meter : -0.3952
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 585.638
Left Arm D1 momentum : 1.741
Left Arm D1 NMR : 0.644288
Left Arm Q3 power supply current : 693.113
Left Arm Q3 momentum : 1.74097
Left Arm Q3 gauss meter : 0.3461
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 92.1222
Current on Unser monitor : 98.6045
Current on Upstream bcm : 92.0292
Current on Downstream bcm : 92.2151
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 131.286
MBSY1c Hall A Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
MBSY1c Bdl : 1.05954e+06
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 4236.99
Tiefenbach Hall C energy : 884.229
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : -0.00898181
IPM1H04A.XPOS : 0.916555
IPM1H04A.YPOS : 0.0736141
IPM1H04B.XPOS : -0.00445437
IPM1H04B.YPOS : -0.0363959
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -2372
HacR_VPM_LVDT:VALr : 323
HacR_HPE1313A:0_Ch58 : -0.530762
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.788574
HacR_alignROLL : -0.307542
HacR_alignPITCH : -0.024159
HacR_alignHPT : -0.17745
HacL_HPM_LVDT:VALr : -7923
HacL_VPM_LVDT:VALr : 2194
HacL_HPE1313A:0_Ch58 : -0.149414
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.109375
HacL_alignROLL : 0.238589
HacL_alignPITCH : -0.111126
HacL_alignHPT : 5.00527
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 20
haL2_Fan_frequency_R : 67.5
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 19.68
haH2_P_Exhaust_R : 20.04
haH2_P_Fill_Bottle_R : 19.81
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.06
haD2_P_Fill_Bottle_R : 37.78
haD2_DP_Fill_Exhaust_R : 0.0744
haSC200_6_Sensor_1_R : 241.93
haSC200_6_Sensor_2_R : 28.31
haSC200_6_Sensor_3_R : 41.23
haSC200_6_Sensor_4_R : 41.59
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 84.72
haITC502_1_Sensor_2_R : 84.71
haITC502_1_Sensor_3_R : 86.99
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 18.99
haITC502_2_Sensor_3_R : 19.25
haITC502_4_Sensor_1_R : 89
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 85.4
haITC502_5_Sensor_2_R : 84.84
haITC502_5_Sensor_3_R : 260.2
haITC502_6_Sensor_1_R : 84.9
haITC502_6_Sensor_2_R : 85.21
haITC502_6_Sensor_3_R : 28.07
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.617041
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 357
Laser power Hall A : 57
Half-wave plate (off=out) : ON