    User name adev

    Log entry time 04:32:52 on April 4, 2001

    Entry number 59900

    keyword=End_of_Run_3345
    ****************************
     Run Number: 3345
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin23,mode=coincidence,Lmom=1.741,Rmom=-1.6880,Ene=4.232,Angle_R=32.991,Angle_L=18.555
    
    Time of run = 97.51289 min
    Av. current (on 3x) = 83.26371 uA
    Av. current (on 1x) = 83.084298 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  486.1074  |  487.1571  |   76.2193
    up-down    (mC)|   -4.3122  |   -1.5983  |  -16.5375
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 3986.433 Hz  |     47877.2 /mC  |    7.973 Hz  |  23323716  |   500   |     47980.6 /mC
        2      | 45115.617 Hz  |    541840.1 /mC  |    9.023 Hz  | 263961250  |  5000   |    543010.2 /mC
        3      | 307953.64 Hz  |   3698533.8 /mC  |    8.675 Hz  | 1801767000  | 35500   |   3706520.4 /mC
        4      | 80403.283 Hz  |    965646.2 /mC  |    8.464 Hz  | 470421390  |  9500   |    967731.4 /mC
        5      | 141.13416 Hz  |      1695.0 /mC  |  141.134 Hz  |    825744  |     1   |      1698.7 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 130.96149 Hz  |      1572.9 /mC  |  130.961 Hz  | 766226.0  |     1   |      1576.2 /mC
        8    | 1024.0 Hz  |     12298.3 /mC  |    0.016 Hz  |   5991192  | 65535   |     12324.8 /mC
        output                       170.411 Hz
    Av. deadtime from accepted triggers = 0.0262
    Av. deadtime from gated scalers = 0.1546
    Accepted triggers  = 997035.00000
    Rate of Left Arm Pulser for electronic DT  = 10.172672
    Rate of Right Arm Pulser for electronic DT  = 10.1778
    Rate of Left Arm Pulser&trig for electronic DT  = 9.990645
    Rate of Right Arm Pulser&trig for electronic DT  = 10.177458
    Left Arm Electronic DT  = 0.017893746
    Right Arm Electronic DT  = 3.3586351e-05
    Rate of Left Strobe  = -210112.32
    Rate of Right Arm Strobe  = 50106.13
        Signal     |    Charge   (C)   
       upstream    |    0.4839513     
       upstream 3x |    0.4863579     
       upstream 10x|    0.0679505     
      downstream   |    0.4882635   
     downstream 3x |    0.4879562   
     downstream 10x|    0.0844880    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3345 at Wed Apr  4 04:32:36 EDT 2001
    Right Arm D1 momentum                    : 1.688
    Right Arm arm angle                      : 32.991
    Left Arm D1 momentum                      : 1.741
    Left Arm arm angle                        : 18.5551
    Tiefenbach Hall A energy                : 4236.99
    Right Arm arm mispointing (HPT)          : -0.178603
    Left Arm arm mispointing (HPT)            : 4.99986
    Right Arm Q1 power supply current        : 1269.17
    Right Arm Q1 momentum                    : 1.68787
    Right Arm Q1 gauss meter                 : -0.03161
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 726.288
    Right Arm Q2 momentum                    : 1.6876
    Right Arm Q2 gauss meter                 : 0.3817
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 581.855
    Right Arm D1 momentum                    : 1.688
    Right Arm D1 NMR                         : 0.626396
    Right Arm Q3 power supply current        : 671.483
    Right Arm Q3 momentum                    : 1.68753
    Right Arm Q3 gauss meter                 : 0.3013
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1309.56
    Left Arm Q1 momentum                      : 1.74067
    Left Arm Q1 gauss meter                   : 0.1115
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 749.464
    Left Arm Q2 momentum                      : 1.74051
    Left Arm Q2 gauss meter                   : -0.3951
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 585.643
    Left Arm D1 momentum                      : 1.741
    Left Arm D1 NMR                           : 0.644288
    Left Arm Q3 power supply current          : 693.227
    Left Arm Q3 momentum                      : 1.74126
    Left Arm Q3 gauss meter                   : 0.3461
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 92.2332
    Current on Unser monitor                : 98.4361
    Current on Upstream bcm                 : 92.1635
    Current on Downstream bcm               : 92.303
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 141.102
    MBSY1c Hall A Beam energy               : 4245.79
    MBSY1c magnet current (amp)             : 176.993
    MBSY1c Bdl                              : 1.05954e+06
    MBSY3c Hall C Beam energy               : 885.654
    Tiefenbach Hall A energy                : 4236.99
    Tiefenbach Hall C energy                : 884.194
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : -0.00093013
    IPM1H04A.XPOS                           : 0.920055
    IPM1H04A.YPOS                           : 0.0685168
    IPM1H04B.XPOS                           : 0.000420568
    IPM1H04B.YPOS                           : -0.0500141
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -2369
     HacR_VPM_LVDT:VALr                     : 305
     HacR_HPE1313A:0_Ch58                   : -0.53125
     HacR_HPE1313A:0_Ch55                   : 22.6562
     HacR_HPE1313A:0_Ch54                   : -0.789062
     HacR_alignROLL                         : -0.307976
     HacR_alignPITCH                        : -0.0237767
     HacR_alignHPT                          : -0.179441
     HacL_HPM_LVDT:VALr                     : -7921
     HacL_VPM_LVDT:VALr                     : 2180
     HacL_HPE1313A:0_Ch58                   : -0.149414
     HacL_HPE1313A:0_Ch55                   : 23.4863
     HacL_HPE1313A:0_Ch54                   : -0.110352
     HacL_alignROLL                         : 0.238148
     HacL_alignPITCH                        : -0.111562
     HacL_alignHPT                          : 5.00325
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 20
    haL2_Fan_frequency_R                     : 67
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 19.79
    haH2_P_Exhaust_R                         : 20.13
    haH2_P_Fill_Bottle_R                     : 19.94
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.21
    haD2_P_Fill_Bottle_R                     : 37.87
    haD2_DP_Fill_Exhaust_R                   : 0.0745
    haSC200_6_Sensor_1_R                     : 241.63
    haSC200_6_Sensor_2_R                     : 28.16
    haSC200_6_Sensor_3_R                     : 41.06
    haSC200_6_Sensor_4_R                     : 41.48
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 84.82
    haITC502_1_Sensor_2_R                    : 84.8
    haITC502_1_Sensor_3_R                    : 87.01
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.25
    haITC502_4_Sensor_1_R                    : 89
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 85.49
    haITC502_5_Sensor_2_R                    : 84.95
    haITC502_5_Sensor_3_R                    : 260.1
    haITC502_6_Sensor_1_R                    : 84.98
    haITC502_6_Sensor_2_R                    : 85.26
    haITC502_6_Sensor_3_R                    : 28.08
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 61.2233
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1382.7
    Wien field                               : 40.224
    Laser attenuation Hall A                 : 362
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON