Log entry time 09:24:46 on April 5, 2001
Entry number 59958
keyword=Start_Run_3365_RunType=Optics,Tar=carbon,Rad=out,comment=kin24,mode=coincidence,Lmom=1.893,Rmom=-1.593,Ene=4.232,Angle_R=33.98,Angle_L=17.456
Beginning-of-run EPICS data for Run Number 3365 at Thu Apr 5 09:24:33 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=500,ps2=5000,ps3=35500,ps4=9500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1197.84
Right Arm Q1 momentum : 1.59301
Right Arm Q1 gauss meter : -0.02984
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 685.72
Right Arm Q2 momentum : 1.59334
Right Arm Q2 gauss meter : 0.3604
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 547.15
Right Arm D1 momentum : 1.593
Right Arm D1 NMR : 0.591142
Right Arm Q3 power supply current : 633.841
Right Arm Q3 momentum : 1.59293
Right Arm Q3 gauss meter : 0.2843
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1424.05
Left Arm Q1 momentum : 1.89284
Left Arm Q1 gauss meter : 0.12106
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 815.351
Left Arm Q2 momentum : 1.89352
Left Arm Q2 gauss meter : -0.4297
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 639.965
Left Arm D1 momentum : 1.893
Left Arm D1 NMR : 0.7005
Left Arm Q3 power supply current : 753.658
Left Arm Q3 momentum : 1.89305
Left Arm Q3 gauss meter : 0.3763
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 24.2227
Current on Unser monitor : 31.9506
Current on Upstream bcm : 24.1951
Current on Downstream bcm : 23.9802
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 72.5307
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.01343
Radiator Encoder : 0.163614
haBDSPOS : 708449
haL1_Fan_frequency_R : 19.5
haL2_Fan_frequency_R : 56
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.53
haSC200_6_Sensor_2_R : 28.06
haSC200_6_Sensor_3_R : 41.13
haSC200_6_Sensor_4_R : 41.41
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 85.1
haITC502_1_Sensor_2_R : 85.11
haITC502_1_Sensor_3_R : 87.55
haITC502_4_Sensor_1_R : 89.5
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 85.77
haITC502_5_Sensor_2_R : 85.26
haITC502_5_Sensor_3_R : 265.5
haITC502_6_Sensor_1_R : 85.33
haITC502_6_Sensor_2_R : 85.74
haITC502_6_Sensor_3_R : 28.25
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -3555
HacR_VPM_LVDT:VALr : 348
HacR_HPE1313A:0_Ch58 : -0.536621
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.819824
HacR_alignROLL : -0.339034
HacR_alignPITCH : -0.01839
HacR_alignHPT : 1.14044
HacL_HPM_LVDT:VALr : -6916
HacL_VPM_LVDT:VALr : 2274
HacL_HPE1313A:0_Ch58 : -0.149414
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.0380859
HacL_alignROLL : 0.30507
HacL_alignPITCH : -0.131527
HacL_alignHPT : 3.8493
Right Arm Angle Floor Angle : 33.5
Right Arm Angle Vernier : 50.8
Right Arm Scattering Angle : 33.9821
Left Arm Angle Floor Angle : 17.5
Left Arm Angle Vernier : 28
Left Arm Scattering Angle : 17.4563
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 179
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88