User name adev
Log entry time 10:38:17 on April 5, 2001
Entry number 59965
keyword=End_of_Run_3368
****************************
Run Number: 3368
End of Run Comment:
RunType=Optics,Tar=9foil-12C,Rad=out,comment=kin24,mode=coincidence,Lmom=1.893,Rmom=-1.593,Ene=4.232,Angle_R=33.98,Angle_L=17.456
suspect vdc thresholds are zero on right side
Time of run = 9.539388 min
Av. current (on 3x) = 24.342407 uA
Av. current (on 1x) = 24.271823 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 13.8923 | 13.9327 | 13.9573
up-down (mC)| -0.1045 | -0.0602 | -0.0432
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 276.04846 Hz | 11340.2 /mC | 276.048 Hz | 158000 | 1 | 11373.2 /mC
2 | 6659.6026 Hz | 273580.3 /mC | 13.319 Hz | 3811712 | 500 | 274375.9 /mC
3 | 12375.983 Hz | 508412.4 /mC | 12375.983 Hz | 7083558 | 1 | 509891.0 /mC
4 | 8277.3042 Hz | 340036.4 /mC | 16.555 Hz | 4737625 | 500 | 341025.2 /mC
5 | 10.65582 Hz | 437.7 /mC | 10.656 Hz | 6099 | 1 | 439.0 /mC
Trigger 5 corrected for pulser:
5 (phys) | 0.496189 Hz | 20.4 /mC | 0.496 Hz | 284.00028 | 1 | 20.4 /mC
8 | 1024.0 Hz | 42066.5 /mC | 0.016 Hz | 586100 | 65535 | 42188.8 /mC
output 732.704 Hz
Av. deadtime from accepted triggers = 0.9422
Av. deadtime from gated scalers = 0.9415
Accepted triggers = 419373.00000
Rate of Left Arm Pulser for electronic DT = 10.159631
Rate of Right Arm Pulser for electronic DT = 10.316874
Rate of Left Arm Pulser&trig for electronic DT = 10.156137
Rate of Right Arm Pulser&trig for electronic DT = 10.316874
Left Arm Electronic DT = 0.00034393809
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 27955.134
Rate of Right Arm Strobe = 7077.6448
Signal | Charge (C)
upstream | 0.0138400
upstream 3x | 0.0139026
upstream 10x| 0.0139357
downstream | 0.0139445
downstream 3x | 0.0139628
downstream 10x| 0.0139789
****************************
End-of-run EPICS data for Run Number 3368 at Thu Apr 5 10:38:00 EDT 2001
Right Arm D1 momentum : 1.593
Right Arm arm angle : 33.9821
Left Arm D1 momentum : 1.893
Left Arm arm angle : 17.4565
Tiefenbach Hall A energy : 4236.99
Right Arm arm mispointing (HPT) : 1.14215
Left Arm arm mispointing (HPT) : 3.82405
Right Arm Q1 power supply current : 1197.73
Right Arm Q1 momentum : 1.59287
Right Arm Q1 gauss meter : -0.02984
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 685.636
Right Arm Q2 momentum : 1.59314
Right Arm Q2 gauss meter : 0.3604
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 547.15
Right Arm D1 momentum : 1.593
Right Arm D1 NMR : 0.591142
Right Arm Q3 power supply current : 633.996
Right Arm Q3 momentum : 1.59332
Right Arm Q3 gauss meter : 0.2844
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1424.01
Left Arm Q1 momentum : 1.8928
Left Arm Q1 gauss meter : 0.12106
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 815.08
Left Arm Q2 momentum : 1.89289
Left Arm Q2 gauss meter : -0.4296
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 639.965
Left Arm D1 momentum : 1.893
Left Arm D1 NMR : 0.700499
Left Arm Q3 power supply current : 753.601
Left Arm Q3 momentum : 1.89319
Left Arm Q3 gauss meter : 0.3763
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 23.7932
Current on Unser monitor : 30.5492
Current on Upstream bcm : 23.7611
Current on Downstream bcm : 23.8252
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 71.9792
MBSY1c Hall A Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
MBSY1c Bdl : 1.05954e+06
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 4236.99
Tiefenbach Hall C energy : 884.236
Delta(E)/E width (MV_AI_DXWID) : 1.0551
IPM1C12.XPOS : -0.000723064
IPM1H04A.XPOS : 0.86329
IPM1H04A.YPOS : 0.0408576
IPM1H04B.XPOS : -0.00170121
IPM1H04B.YPOS : -0.0531582
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -3556
HacR_VPM_LVDT:VALr : 343
HacR_HPE1313A:0_Ch58 : -0.538086
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.820312
HacR_alignROLL : -0.339962
HacR_alignPITCH : -0.0184565
HacR_alignHPT : 1.14209
HacL_HPM_LVDT:VALr : -6893
HacL_VPM_LVDT:VALr : 2272
HacL_HPE1313A:0_Ch58 : -0.150391
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.0390625
HacL_alignROLL : 0.3036
HacL_alignPITCH : -0.131016
HacL_alignHPT : 3.82431
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 20
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 25
haH2_P_Fill_Target_R : 21.11
haH2_P_Exhaust_R : 21.46
haH2_P_Fill_Bottle_R : 21.17
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -680
haD2_P_Exhaust_R : 19.25
haD2_P_Fill_Bottle_R : 39.74
haD2_DP_Fill_Exhaust_R : 0.0746
haSC200_6_Sensor_1_R : 241.48
haSC200_6_Sensor_2_R : 28.08
haSC200_6_Sensor_3_R : 41.1
haSC200_6_Sensor_4_R : 41.43
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 85.39
haITC502_1_Sensor_2_R : 85.37
haITC502_1_Sensor_3_R : 87.82
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.01
haITC502_4_Sensor_1_R : 89.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 86.06
haITC502_5_Sensor_2_R : 85.51
haITC502_5_Sensor_3_R : 263.4
haITC502_6_Sensor_1_R : 85.53
haITC502_6_Sensor_2_R : 85.95
haITC502_6_Sensor_3_R : 28.07
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616943
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 180
Laser power Hall A : 57
Half-wave plate (off=out) : ON