User name adev
Log entry time 11:29:21 on April 5, 2001
Entry number 59973
keyword=Start_Run_3372_RunType=Optics,Tar=carbon,Rad=out,comment=kin24,mode=coincidence,Lmom=1.893,Rmom=-1.593,Ene=4.232,Angle_R=33.98,Angle_L=17.456
Beginning-of-run EPICS data for Run Number 3372 at Thu Apr 5 11:29:03 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=500,ps3=12,ps4=500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1197.77
Right Arm Q1 momentum : 1.59292
Right Arm Q1 gauss meter : -0.02984
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 685.491
Right Arm Q2 momentum : 1.59281
Right Arm Q2 gauss meter : 0.3604
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 547.159
Right Arm D1 momentum : 1.593
Right Arm D1 NMR : 0.591143
Right Arm Q3 power supply current : 634.086
Right Arm Q3 momentum : 1.59355
Right Arm Q3 gauss meter : 0.2843
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1424.05
Left Arm Q1 momentum : 1.89284
Left Arm Q1 gauss meter : 0.12108
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 815.013
Left Arm Q2 momentum : 1.89274
Left Arm Q2 gauss meter : -0.4296
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 639.966
Left Arm D1 momentum : 1.893
Left Arm D1 NMR : 0.700499
Left Arm Q3 power supply current : 753.603
Left Arm Q3 momentum : 1.89301
Left Arm Q3 gauss meter : 0.3763
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 23.6836
Current on Unser monitor : 31.4367
Current on Upstream bcm : 23.6892
Current on Downstream bcm : 23.7925
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 71.4878
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 4.9939
Radiator Encoder : 0.15873
haBDSPOS : 708450
haL1_Fan_frequency_R : 20
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.44
haSC200_6_Sensor_2_R : 28.11
haSC200_6_Sensor_3_R : 41.11
haSC200_6_Sensor_4_R : 41.41
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 85.56
haITC502_1_Sensor_2_R : 85.51
haITC502_1_Sensor_3_R : 87.92
haITC502_4_Sensor_1_R : 89.8
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 86.19
haITC502_5_Sensor_2_R : 85.67
haITC502_5_Sensor_3_R : 265
haITC502_6_Sensor_1_R : 85.69
haITC502_6_Sensor_2_R : 86.05
haITC502_6_Sensor_3_R : 28.16
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3556
HacR_VPM_LVDT:VALr : 375
HacR_HPE1313A:0_Ch58 : -0.538086
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.820801
HacR_alignROLL : -0.339092
HacR_alignPITCH : -0.0183236
HacR_alignHPT : 1.14159
HacL_HPM_LVDT:VALr : -6930
HacL_VPM_LVDT:VALr : 2294
HacL_HPE1313A:0_Ch58 : -0.149414
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.0390625
HacL_alignROLL : 0.3036
HacL_alignPITCH : -0.131016
HacL_alignHPT : 3.86565
Right Arm Angle Floor Angle : 33.5
Right Arm Angle Vernier : 50.8
Right Arm Scattering Angle : 33.9821
Left Arm Angle Floor Angle : 17.5
Left Arm Angle Vernier : 28
Left Arm Scattering Angle : 17.4562
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field :
Laser attenuation Hall A : 177
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88