User name adev
Log entry time 12:30:09 on April 5, 2001
Entry number 59975
keyword=Start_Run_3373_RunType=Other,Tar=BeO,Rad=out,comment=kin24,mode=coincidence,Lmom=1.893,Rmom=-1.593,Ene=4.232,Angle_R=33.98,Angle_L=17.456
Beginning-of-run EPICS data for Run Number 3373 at Thu Apr 5 12:29:53 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=500,ps3=12,ps4=500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1197.73
Right Arm Q1 momentum : 1.59287
Right Arm Q1 gauss meter : -0.02985
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 685.541
Right Arm Q2 momentum : 1.59292
Right Arm Q2 gauss meter : 0.3603
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 547.158
Right Arm D1 momentum : 1.593
Right Arm D1 NMR : 0.591143
Right Arm Q3 power supply current : 633.937
Right Arm Q3 momentum : 1.59317
Right Arm Q3 gauss meter : 0.2843
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1424.01
Left Arm Q1 momentum : 1.8928
Left Arm Q1 gauss meter : 0.12109
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 815.267
Left Arm Q2 momentum : 1.89333
Left Arm Q2 gauss meter : -0.4296
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 639.967
Left Arm D1 momentum : 1.893
Left Arm D1 NMR : 0.700499
Left Arm Q3 power supply current : 753.585
Left Arm Q3 momentum : 1.89287
Left Arm Q3 gauss meter : 0.3763
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 4.79031
Current on Unser monitor : 11.8556
Current on Upstream bcm : 4.863
Current on Downstream bcm : 4.71761
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 53.1878
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.156288
haBDSPOS : 190450
haL1_Fan_frequency_R : 20
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.44
haSC200_6_Sensor_2_R : 28.23
haSC200_6_Sensor_3_R : 41.13
haSC200_6_Sensor_4_R : 41.41
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 85.98
haITC502_1_Sensor_2_R : 85.95
haITC502_1_Sensor_3_R : 88.38
haITC502_4_Sensor_1_R : 90.2
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 86.74
haITC502_5_Sensor_2_R : 86.12
haITC502_5_Sensor_3_R : 265.4
haITC502_6_Sensor_1_R : 86.22
haITC502_6_Sensor_2_R : 86.66
haITC502_6_Sensor_3_R : 27.74
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3560
HacR_VPM_LVDT:VALr : 380
HacR_HPE1313A:0_Ch58 : -0.537598
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.820801
HacR_alignROLL : -0.340136
HacR_alignPITCH : -0.0178082
HacR_alignHPT : 1.14554
HacL_HPM_LVDT:VALr : -6931
HacL_VPM_LVDT:VALr : 2300
HacL_HPE1313A:0_Ch58 : -0.149902
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.0395508
HacL_alignROLL : 0.304064
HacL_alignPITCH : -0.131016
HacL_alignHPT : 3.86543
Right Arm Angle Floor Angle : 33.5
Right Arm Angle Vernier : 50.8
Right Arm Scattering Angle : 33.982
Left Arm Angle Floor Angle : 17.5
Left Arm Angle Vernier : 28
Left Arm Scattering Angle : 17.4562
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 200
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88