User name adev
Log entry time 14:44:27 on April 5, 2001
Entry number 59980
keyword=Start_Run_3374_RunType=Other,Tar=absence,Rad=out,comment=No
Beginning-of-run EPICS data for Run Number 3374 at Thu Apr 5 14:44:15 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=500,ps3=12,ps4=500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1197.77
Right Arm Q1 momentum : 1.59292
Right Arm Q1 gauss meter : -0.02985
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 685.797
Right Arm Q2 momentum : 1.59351
Right Arm Q2 gauss meter : 0.3605
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 547.157
Right Arm D1 momentum : 1.593
Right Arm D1 NMR : 0.591143
Right Arm Q3 power supply current : 633.87
Right Arm Q3 momentum : 1.593
Right Arm Q3 gauss meter : 0.2843
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1424.05
Left Arm Q1 momentum : 1.89284
Left Arm Q1 gauss meter : 0.12109
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 815.233
Left Arm Q2 momentum : 1.89325
Left Arm Q2 gauss meter : -0.4296
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 639.967
Left Arm D1 momentum : 1.893
Left Arm D1 NMR : 0.700498
Left Arm Q3 power supply current : 753.683
Left Arm Q3 momentum : 1.89311
Left Arm Q3 gauss meter : 0.3763
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0424241
Current on Unser monitor : 6.26061
Current on Upstream bcm : 0.0516397
Current on Downstream bcm : 0.0332086
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 47.372
Beam energy : 4245.79
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply : 4.83028
Radiator Encoder : 0.15873
haBDSPOS : 3.81452e+06
haL1_Fan_frequency_R : 20
haL2_Fan_frequency_R : 29
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.38
haSC200_6_Sensor_2_R : 28.98
haSC200_6_Sensor_3_R : 41.11
haSC200_6_Sensor_4_R : 41.43
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 92.09
haITC502_1_Sensor_2_R : 92.01
haITC502_1_Sensor_3_R : 93.49
haITC502_4_Sensor_1_R : 94.6
haITC502_4_Sensor_2_R : 57.9
haITC502_4_Sensor_3_R : 45.8
haITC502_5_Sensor_1_R : 93.21
haITC502_5_Sensor_2_R : 92.1
haITC502_5_Sensor_3_R : 256.9
haITC502_6_Sensor_1_R : 92.22
haITC502_6_Sensor_2_R : 91.92
haITC502_6_Sensor_3_R : 26.89
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -3559
HacR_VPM_LVDT:VALr : 362
HacR_HPE1313A:0_Ch58 : -0.537598
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.822266
HacR_alignROLL : -0.341064
HacR_alignPITCH : -0.0178747
HacR_alignHPT : 1.14607
HacL_HPM_LVDT:VALr : -6894
HacL_VPM_LVDT:VALr : 2295
HacL_HPE1313A:0_Ch58 : -0.150391
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.0395508
HacL_alignROLL : 0.302518
HacL_alignPITCH : -0.129994
HacL_alignHPT : 3.82483
Right Arm Angle Floor Angle : 33.5
Right Arm Angle Vernier : 50.8
Right Arm Scattering Angle : 33.982
Left Arm Angle Floor Angle : 17.5
Left Arm Angle Vernier : 28
Left Arm Scattering Angle : 17.4565
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 200
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88