User name adev
Log entry time 16:41:07 on April 7, 2001
Entry number 60004
keyword=Start_Run_3378_RunType=Other,Tar=absence,Rad=out,comment=No
Beginning-of-run EPICS data for Run Number 3378 at Sat Apr 7 16:40:53 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=500,ps3=12,ps4=500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1197.84
Right Arm Q1 momentum : 1.59301
Right Arm Q1 gauss meter : -0.02984
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 685.521
Right Arm Q2 momentum : 1.59287
Right Arm Q2 gauss meter : 0.3603
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 548.291
Right Arm D1 momentum : 1.593
Right Arm D1 NMR : 0.591142
Right Arm Q3 power supply current : 634.008
Right Arm Q3 momentum : 1.59335
Right Arm Q3 gauss meter : 0.2844
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1424.01
Left Arm Q1 momentum : 1.8928
Left Arm Q1 gauss meter : 0.12104
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 814.949
Left Arm Q2 momentum : 1.89259
Left Arm Q2 gauss meter : -0.4296
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 640.531
Left Arm D1 momentum : 1.893
Left Arm D1 NMR : 0.700501
Left Arm Q3 power supply current : 753.894
Left Arm Q3 momentum : 1.89364
Left Arm Q3 gauss meter : 0.3765
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 7.07836
Current on Unser monitor : 15.2474
Current on Upstream bcm : 7.07087
Current on Downstream bcm : 7.08584
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 7.10562
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.17094
haBDSPOS : 164850
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.41
haSC200_6_Sensor_2_R : 38.89
haSC200_6_Sensor_3_R : 41.39
haSC200_6_Sensor_4_R : 41.49
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 182.1
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 279.3
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 29.27
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -3513
HacR_VPM_LVDT:VALr : 425
HacR_HPE1313A:0_Ch58 : -0.538086
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.825195
HacR_alignROLL : -0.345065
HacR_alignPITCH : -0.0178082
HacR_alignHPT : 1.09798
HacL_HPM_LVDT:VALr : -6870
HacL_VPM_LVDT:VALr : 2309
HacL_HPE1313A:0_Ch58 : -0.151367
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.0400391
HacL_alignROLL : 0.303059
HacL_alignPITCH : -0.129632
HacL_alignHPT : 3.79775
Right Arm Angle Floor Angle : 33.5
Right Arm Angle Vernier : 50.8
Right Arm Scattering Angle : 33.9824
Left Arm Angle Floor Angle : 17.5
Left Arm Angle Vernier : 28
Left Arm Scattering Angle : 17.4567
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 60
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88