User name adev
Log entry time 17:11:11 on April 7, 2001
Entry number 60006
keyword=Start_Run_3379_RunType=Other,Tar=LH2-15cm,Rad=out,comment=No
Beginning-of-run EPICS data for Run Number 3379 at Sat Apr 7 17:10:51 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=500,ps3=12,ps4=500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1197.88
Right Arm Q1 momentum : 1.59306
Right Arm Q1 gauss meter : -0.02983
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 685.629
Right Arm Q2 momentum : 1.59313
Right Arm Q2 gauss meter : 0.3604
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 548.289
Right Arm D1 momentum : 1.593
Right Arm D1 NMR : 0.591142
Right Arm Q3 power supply current : 633.607
Right Arm Q3 momentum : 1.59234
Right Arm Q3 gauss meter : 0.2843
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1424.05
Left Arm Q1 momentum : 1.89284
Left Arm Q1 gauss meter : 0.12105
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 815.331
Left Arm Q2 momentum : 1.89294
Left Arm Q2 gauss meter : -0.4296
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 640.53
Left Arm D1 momentum : 1.893
Left Arm D1 NMR : 0.700499
Left Arm Q3 power supply current : 753.675
Left Arm Q3 momentum : 1.89309
Left Arm Q3 gauss meter : 0.3764
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 6.91952
Current on Unser monitor : 14.9816
Current on Upstream bcm : 6.90557
Current on Downstream bcm : 6.93346
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 7.50243
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.166056
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 67.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.41
haSC200_6_Sensor_2_R : 37.86
haSC200_6_Sensor_3_R : 41.41
haSC200_6_Sensor_4_R : 41.49
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 172.2
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 276.1
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 29.19
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3498
HacR_VPM_LVDT:VALr : 401
HacR_HPE1313A:0_Ch58 : -0.537598
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.825684
HacR_alignROLL : -0.34463
HacR_alignPITCH : -0.0177418
HacR_alignHPT : 1.07982
HacL_HPM_LVDT:VALr : -6853
HacL_VPM_LVDT:VALr : 2280
HacL_HPE1313A:0_Ch58 : -0.150879
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.0400391
HacL_alignROLL : 0.303524
HacL_alignPITCH : -0.130068
HacL_alignHPT : 3.77988
Right Arm Angle Floor Angle : 33.5
Right Arm Angle Vernier : 50.8
Right Arm Scattering Angle : 33.9825
Left Arm Angle Floor Angle : 17.5
Left Arm Angle Vernier : 28
Left Arm Scattering Angle : 17.4568
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 140
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88