User name adev
Log entry time 01:21:21 on April 8, 2001
Entry number 60020
keyword=End_of_Run_3381
****************************
Run Number: 3381
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=,mode=coincidence,Lmom=1.893,Rmom=-1.593,Ene=4.232,Angle_R=33.98,Angle_L=17.456
Time of run = 90.939682 min
Av. current (on 3x) = 88.572812 uA
Av. current (on 1x) = 88.378764 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 482.2282 | 483.2870 | 67.7907
up-down (mC)| -4.1035 | -1.3578 | -16.5888
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 4730.6708 Hz | 53410.0 /mC | 9.461 Hz | 25812342 | 500 | 53527.2 /mC
2 | 45136.877 Hz | 509601.9 /mC | 9.027 Hz | 246283990 | 5000 | 510720.8 /mC
3 | 293516.83 Hz | 3313847.9 /mC | 8.268 Hz | 1601539600 | 35500 | 3321123.9 /mC
4 | 80754.542 Hz | 911730.6 /mC | 8.500 Hz | 440627540 | 9500 | 913732.4 /mC
5 | 153.05493 Hz | 1728.0 /mC | 153.055 Hz | 835126 | 1 | 1731.8 /mC
Trigger 5 corrected for pulser:
5 (phys) | 142.8806 Hz | 1613.1 /mC | 142.881 Hz | 779611.0 | 1 | 1616.7 /mC
8 | 1024.0 Hz | 11561.1 /mC | 0.016 Hz | 5587334 | 65535 | 11586.5 /mC
output 182.876 Hz
Av. deadtime from accepted triggers = 0.0273
Av. deadtime from gated scalers = 0.1818
Accepted triggers = 997843.00000
Rate of Left Arm Pulser for electronic DT = 10.174326
Rate of Right Arm Pulser for electronic DT = 10.182207
Rate of Left Arm Pulser&trig for electronic DT = 10.011031
Rate of Right Arm Pulser&trig for electronic DT = 10.182024
Left Arm Electronic DT = 0.016049716
Right Arm Electronic DT = 1.7999208e-05
Rate of Left Strobe = -318523.57
Rate of Right Arm Strobe = 50393.945
Signal | Charge (C)
upstream | 0.4801764
upstream 3x | 0.4826081
upstream 10x| 0.0594963
downstream | 0.4842799
downstream 3x | 0.4839659
downstream 10x| 0.0760851
****************************
End-of-run EPICS data for Run Number 3381 at Sat Apr 7 19:22:06 EDT 2001
Right Arm D1 momentum : 1.593
Right Arm arm angle : 33.9825
Left Arm D1 momentum : 1.89301
Left Arm arm angle : 17.4567
Tiefenbach Hall A energy : 4236.96
Right Arm arm mispointing (HPT) : 1.07811
Left Arm arm mispointing (HPT) : 3.78993
Right Arm Q1 power supply current : 1197.88
Right Arm Q1 momentum : 1.59306
Right Arm Q1 gauss meter : -0.02982
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 685.429
Right Arm Q2 momentum : 1.59266
Right Arm Q2 gauss meter : 0.3603
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 548.299
Right Arm D1 momentum : 1.593
Right Arm D1 NMR : 0.591143
Right Arm Q3 power supply current : 633.639
Right Arm Q3 momentum : 1.59242
Right Arm Q3 gauss meter : 0.2843
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1424.11
Left Arm Q1 momentum : 1.89294
Left Arm Q1 gauss meter : 0.12104
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 815.254
Left Arm Q2 momentum : 1.8933
Left Arm Q2 gauss meter : -0.4296
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 640.529
Left Arm D1 momentum : 1.89301
Left Arm D1 NMR : 0.700502
Left Arm Q3 power supply current : 753.502
Left Arm Q3 momentum : 1.89266
Left Arm Q3 gauss meter : 0.3763
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 95.2074
Current on Unser monitor : 102.088
Current on Upstream bcm : 95.1633
Current on Downstream bcm : 95.2787
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 95.9339
MBSY1c Hall A Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
MBSY1c Bdl : 1.05954e+06
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 4236.96
Tiefenbach Hall C energy : 884.215
Delta(E)/E width (MV_AI_DXWID) : 1.05553
IPM1C12.XPOS :
IPM1H04A.XPOS : 0.791216
IPM1H04A.YPOS : 0.123561
IPM1H04B.XPOS : -0.0543849
IPM1H04B.YPOS : -0.0162655
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3493
HacR_VPM_LVDT:VALr : 356
HacR_HPE1313A:0_Ch58 : -0.536621
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.825684
HacR_alignROLL : -0.345123
HacR_alignPITCH : -0.0172929
HacR_alignHPT : 1.08346
HacL_HPM_LVDT:VALr : -6874
HacL_VPM_LVDT:VALr : 2208
HacL_HPE1313A:0_Ch58 : -0.151855
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.0410156
HacL_alignROLL : 0.303135
HacL_alignPITCH : -0.129706
HacL_alignHPT : 3.79883
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 20.11
haH2_P_Exhaust_R : 20.44
haH2_P_Fill_Bottle_R : 20.12
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.44
haD2_P_Fill_Bottle_R : 38.2
haD2_DP_Fill_Exhaust_R : 0.0747
haSC200_6_Sensor_1_R : 241.49
haSC200_6_Sensor_2_R : 29.62
haSC200_6_Sensor_3_R : 41.44
haSC200_6_Sensor_4_R : 41.48
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.16
haITC502_4_Sensor_1_R : 102.4
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 270.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.75
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616943
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 410
Laser power Hall A : 57
Half-wave plate (off=out) : ON