User name adev
Log entry time 17:03:32 on April 8, 2001
Entry number 60046
keyword=End_of_Run_3394
****************************
Run Number: 3394
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin 24 continuing,mode=coincidence,Lmom=1.893,Rmom=-1.593,Ene=4.232,Angle_R=33.98,Angle_L=17.456
Time of run = 72.320345 min
Av. current (on 3x) = 90.750973 uA
Av. current (on 1x) = 90.544599 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 392.8930 | 393.7885 | -10.6726
up-down (mC)| -3.4258 | -1.1440 | -14.7594
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 4867.9264 Hz | 53640.5 /mC | 9.736 Hz | 21123007 | 500 | 53762.7 /mC
2 | 46883.785 Hz | 516620.2 /mC | 9.377 Hz | 203439090 | 5000 | 517797.7 /mC
3 | 302038.49 Hz | 3328212.2 /mC | 8.508 Hz | 1310611700 | 35500 | 3335798.0 /mC
4 | 84058.687 Hz | 926256.6 /mC | 8.848 Hz | 364749190 | 9500 | 928367.8 /mC
5 | 160.12207 Hz | 1764.4 /mC | 160.122 Hz | 694805 | 1 | 1768.4 /mC
Trigger 5 corrected for pulser:
5 (phys) | 149.95066 Hz | 1652.3 /mC | 149.951 Hz | 650669.0 | 1 | 1656.1 /mC
8 | 1024.0 Hz | 11283.6 /mC | 0.016 Hz | 4443362 | 65535 | 11309.3 /mC
output 190.716 Hz
Av. deadtime from accepted triggers = 0.0284
Av. deadtime from gated scalers = -0.5023
Accepted triggers = 827560.00000
Rate of Left Arm Pulser for electronic DT = 10.171412
Rate of Right Arm Pulser for electronic DT = 10.181552
Rate of Left Arm Pulser&trig for electronic DT = 10.004101
Rate of Right Arm Pulser&trig for electronic DT = 10.181552
Left Arm Electronic DT = 0.016449157
Right Arm Electronic DT = 0.0
Rate of Left Strobe = -483511.32
Rate of Right Arm Strobe = 52741.702
Signal | Charge (C)
upstream | 0.3911801
upstream 3x | 0.3932165
upstream 10x| -0.0180523
downstream | 0.3946059
downstream 3x | 0.3943605
downstream 10x| -0.0032929
****************************
End-of-run EPICS data for Run Number 3394 at Sun Apr 8 17:03:18 EDT 2001
Right Arm D1 momentum : 1.593
Right Arm arm angle : 33.9823
Left Arm D1 momentum : 1.89301
Left Arm arm angle : 17.4566
Tiefenbach Hall A energy : 4236.98
Right Arm arm mispointing (HPT) : 1.1111
Left Arm arm mispointing (HPT) : 3.81265
Right Arm Q1 power supply current : 1197.98
Right Arm Q1 momentum : 1.5932
Right Arm Q1 gauss meter : -0.02983
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 685.612
Right Arm Q2 momentum : 1.59308
Right Arm Q2 gauss meter : 0.3602
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 548.3
Right Arm D1 momentum : 1.593
Right Arm D1 NMR : 0.591144
Right Arm Q3 power supply current : 633.957
Right Arm Q3 momentum : 1.59322
Right Arm Q3 gauss meter : 0.2843
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1424.01
Left Arm Q1 momentum : 1.8928
Left Arm Q1 gauss meter : 0.12102
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 815.175
Left Arm Q2 momentum : 1.89312
Left Arm Q2 gauss meter : -0.4295
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 640.522
Left Arm D1 momentum : 1.893
Left Arm D1 NMR : 0.700501
Left Arm Q3 power supply current : 753.742
Left Arm Q3 momentum : 1.89326
Left Arm Q3 gauss meter : 0.3763
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0562479
Current on Unser monitor : 7.07532
Current on Upstream bcm : 0.0583297
Current on Downstream bcm : 0.0541661
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
MBSY1c Bdl : 1.05954e+06
MBSY3c Hall C Beam energy : 3407.17
Tiefenbach Hall A energy : 4236.98
Tiefenbach Hall C energy : 3398.47
Delta(E)/E width (MV_AI_DXWID) : 1.05553
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3527
HacR_VPM_LVDT:VALr : 336
HacR_HPE1313A:0_Ch58 : -0.536133
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.823242
HacR_alignROLL : -0.342485
HacR_alignPITCH : -0.0192878
HacR_alignHPT : 1.11106
HacL_HPM_LVDT:VALr : -6885
HacL_VPM_LVDT:VALr : 2199
HacL_HPE1313A:0_Ch58 : -0.150879
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.0410156
HacL_alignROLL : 0.302205
HacL_alignPITCH : -0.130143
HacL_alignHPT : 3.81492
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 68.5
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 21.94
haH2_P_Exhaust_R : 22.37
haH2_P_Fill_Bottle_R : 22.02
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 19.93
haD2_P_Fill_Bottle_R : 41.16
haD2_DP_Fill_Exhaust_R : 0.0746
haSC200_6_Sensor_1_R : 241.73
haSC200_6_Sensor_2_R : 26.72
haSC200_6_Sensor_3_R : 41.68
haSC200_6_Sensor_4_R : 41.59
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.81
haITC502_1_Sensor_3_R : 80.97
haITC502_2_Sensor_1_R : 19.01
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 18.94
haITC502_4_Sensor_1_R : 88
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 96.04
haITC502_5_Sensor_2_R : 93.79
haITC502_5_Sensor_3_R : 268.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 85.77
haITC502_6_Sensor_3_R : 28.99
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.617041
Wien angle : 43.1664
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 964.77
Wien field : 28.089
Laser attenuation Hall A : 120
Laser power Hall A : 57
Half-wave plate (off=out) : ON