Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 23:34:29 on April 9, 2001
Entry number 60087
keyword=Start_Run_3408_RunType=Other,Tar=LH2-15cm,Rad=out,comment=right
Beginning-of-run EPICS data for Run Number 3408 at Mon Apr 9 23:34:15 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=500,ps2=5000,ps3=35500,ps4=9500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1300.84
Right Arm Q1 momentum : 1.73
Right Arm Q1 gauss meter : -0.03238
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 744.516
Right Arm Q2 momentum : 1.72995
Right Arm Q2 gauss meter : 0.3913
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 597.037
Right Arm D1 momentum : 1.73
Right Arm D1 NMR : 0.641982
Right Arm Q3 power supply current : 688.308
Right Arm Q3 momentum : 1.72981
Right Arm Q3 gauss meter : 0.3089
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1423.94
Left Arm Q1 momentum : 1.8927
Left Arm Q1 gauss meter : 0.12102
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 815.184
Left Arm Q2 momentum : 1.89314
Left Arm Q2 gauss meter : -0.4296
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 640.521
Left Arm D1 momentum : 1.893
Left Arm D1 NMR : 0.7005
Left Arm Q3 power supply current : 753.586
Left Arm Q3 momentum : 1.89287
Left Arm Q3 gauss meter : 0.3764
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 88.8839
Current on Unser monitor : 95.7128
Current on Upstream bcm : 88.8347
Current on Downstream bcm : 88.933
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 132.266
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 70
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.68
haSC200_6_Sensor_2_R : 26.45
haSC200_6_Sensor_3_R : 41.76
haSC200_6_Sensor_4_R : 41.54
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.23
haITC502_1_Sensor_2_R : 93.53
haITC502_1_Sensor_3_R : 80.16
haITC502_4_Sensor_1_R : 86.8
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 94.71
haITC502_5_Sensor_2_R : 92.48
haITC502_5_Sensor_3_R : 267.6
haITC502_6_Sensor_1_R : 98.54
haITC502_6_Sensor_2_R : 84.46
haITC502_6_Sensor_3_R : 28.84
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -608
HacR_VPM_LVDT:VALr : 72
HacR_HPE1313A:0_Ch58 : -0.543457
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.771973
HacR_alignROLL : -0.291156
HacR_alignPITCH : -0.0121719
HacR_alignHPT : -2.16025
HacL_HPM_LVDT:VALr : -6878
HacL_VPM_LVDT:VALr : 2135
HacL_HPE1313A:0_Ch58 : -0.150391
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.046875
HacL_alignROLL : 0.296856
HacL_alignPITCH : -0.130803
HacL_alignHPT : 3.80967
Right Arm Angle Floor Angle : 29
Right Arm Angle Vernier : 2.5
Right Arm Scattering Angle : 29.226
Left Arm Angle Floor Angle : 17.5
Left Arm Angle Vernier : 28
Left Arm Scattering Angle : 17.4566
Wien angle : 43.1664
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 964.77
Wien field : 28.089
Laser attenuation Hall A : 408
Laser power Hall A : 0
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88