User name adev
Log entry time 07:57:24 on April 11, 2001
Entry number 60169
keyword=End_of_Run_3437
****************************
Run Number: 3437
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin27,mode=coincidence,Lmom=1.986,Rmom=-1.65,Ene=4.232,Angle_R=29.94,Angle_L=16.820
Time of run = 58.324218 min
Av. current (on 3x) = 88.17032 uA
Av. current (on 1x) = 87.9534 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 307.7888 | 308.5479 | -73.8133
up-down (mC)| -2.6474 | -0.9176 | -12.5641
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 9371.1955 Hz | 106285.1 /mC | 10.412 Hz | 32794059 | 900 | 106547.3 /mC
2 | 50826.804 Hz | 576461.6 /mC | 10.165 Hz | 177866020 | 5000 | 577883.3 /mC
3 | 271599.13 Hz | 3080391.8 /mC | 7.651 Hz | 950448430 | 35500 | 3087989.0 /mC
4 | 82911.732 Hz | 940358.8 /mC | 8.728 Hz | 290145720 | 9500 | 942678.0 /mC
5 | 261.02021 Hz | 2960.4 /mC | 261.020 Hz | 913428 | 1 | 2967.7 /mC
Trigger 5 corrected for pulser:
5 (phys) | 250.84834 Hz | 2845.0 /mC | 250.848 Hz | 877832.0 | 1 | 2852.1 /mC
8 | 1024.0 Hz | 11613.9 /mC | 0.016 Hz | 3583440 | 65535 | 11642.5 /mC
output 285.499 Hz
Av. deadtime from accepted triggers = 0.0410
Av. deadtime from gated scalers = -0.1324
Accepted triggers = 999090.00000
Rate of Left Arm Pulser for electronic DT = 10.171875
Rate of Right Arm Pulser for electronic DT = 10.198451
Rate of Left Arm Pulser&trig for electronic DT = 10.012707
Rate of Right Arm Pulser&trig for electronic DT = 10.197879
Left Arm Electronic DT = 0.015647826
Right Arm Electronic DT = 5.6039676e-05
Rate of Left Strobe = 473072.37
Rate of Right Arm Strobe = 62342.284
Signal | Charge (C)
upstream | 0.3064651
upstream 3x | 0.3080891
upstream 10x| -0.0800954
downstream | 0.3091125
downstream 3x | 0.3090067
downstream 10x| -0.0675313
****************************
End-of-run EPICS data for Run Number 3437 at Wed Apr 11 07:57:02 EDT 2001
Right Arm D1 momentum : 1.65
Right Arm arm angle : 29.9397
Left Arm D1 momentum : 1.986
Left Arm arm angle : 16.8199
Tiefenbach Hall A energy : 4236.98
Right Arm arm mispointing (HPT) : -1.44729
Left Arm arm mispointing (HPT) : 4.41862
Right Arm Q1 power supply current : 1240.65
Right Arm Q1 momentum : 1.64994
Right Arm Q1 gauss meter : -0.0309
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 710.07
Right Arm Q2 momentum : 1.64992
Right Arm Q2 gauss meter : 0.3732
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 567.562
Right Arm D1 momentum : 1.65
Right Arm D1 NMR : 0.612295
Right Arm Q3 power supply current : 656.608
Right Arm Q3 momentum : 1.65015
Right Arm Q3 gauss meter : 0.2945
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1494.08
Left Arm Q1 momentum :
Left Arm Q1 gauss meter : 0.12693
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 855.214
Left Arm Q2 momentum : 1.9861
Left Arm Q2 gauss meter : -0.4507
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 674.047
Left Arm D1 momentum : 1.986
Left Arm D1 NMR : 0.734892
Left Arm Q3 power supply current : 790.717
Left Arm Q3 momentum : 1.98613
Left Arm Q3 gauss meter : 0.3948
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 90.4111
Current on Unser monitor : 96.2729
Current on Upstream bcm : 90.348
Current on Downstream bcm : 90.8014
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 139.562
MBSY1c Hall A Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
MBSY1c Bdl : 1.05954e+06
MBSY3c Hall C Beam energy : 3408.77
Tiefenbach Hall A energy : 4236.98
Tiefenbach Hall C energy : 3399.66
Delta(E)/E width (MV_AI_DXWID) : 1.05553
IPM1C12.XPOS : 0.00672343
IPM1H04A.XPOS : 0.853133
IPM1H04A.YPOS : 0.051251
IPM1H04B.XPOS : 0.0156842
IPM1H04B.YPOS : -0.0770179
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -1256
HacR_VPM_LVDT:VALr : 29
HacR_HPE1313A:0_Ch58 : -0.541992
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.752441
HacR_alignROLL : -0.270824
HacR_alignPITCH : -0.0145491
HacR_alignHPT : -1.4476
HacL_HPM_LVDT:VALr : -7439
HacL_VPM_LVDT:VALr : 2198
HacL_HPE1313A:0_Ch58 : -0.14502
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.00732422
HacL_alignROLL : 0.334653
HacL_alignPITCH : -0.135755
HacL_alignHPT : 4.41836
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 20.17
haH2_P_Exhaust_R : 20.57
haH2_P_Fill_Bottle_R : 20.22
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.5
haD2_P_Fill_Bottle_R : 38.35
haD2_DP_Fill_Exhaust_R : 0.0746
haSC200_6_Sensor_1_R : 241.79
haSC200_6_Sensor_2_R : 26.3
haSC200_6_Sensor_3_R : 42.16
haSC200_6_Sensor_4_R : 41.51
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 93.88
haITC502_1_Sensor_2_R : 93.19
haITC502_1_Sensor_3_R : 79.55
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.22
haITC502_4_Sensor_1_R : 86.2
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 94.34
haITC502_5_Sensor_2_R : 92.2
haITC502_5_Sensor_3_R : 267.1
haITC502_6_Sensor_1_R : 98.1
haITC502_6_Sensor_2_R : 83.9
haITC502_6_Sensor_3_R : 28.8
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616992
Wien angle : 43.1664
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 964.77
Wien field : 28.089
Laser attenuation Hall A : 311
Laser power Hall A : 57
Half-wave plate (off=out) : OFF