User name adev
Log entry time 02:32:34 on April 13, 2001
Entry number 60300
keyword=Start_Run_3489_RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin30,
Beginning-of-run EPICS data for Run Number 3489 at Fri Apr 13 02:32:24 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=900,ps2=5000,ps3=60000,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1240.61
Right Arm Q1 momentum : 1.64989
Right Arm Q1 gauss meter : -0.0309
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 710.237
Right Arm Q2 momentum : 1.6503
Right Arm Q2 gauss meter : 0.3732
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 567.572
Right Arm D1 momentum : 1.65
Right Arm D1 NMR : 0.612294
Right Arm Q3 power supply current : 656.546
Right Arm Q3 momentum : 1.6503
Right Arm Q3 gauss meter : 0.2946
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1451.87
Left Arm Q1 momentum : 1.92983
Left Arm Q1 gauss meter : 0.12338
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 831.123
Left Arm Q2 momentum : 1.93015
Left Arm Q2 gauss meter : -0.438
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 653.827
Left Arm D1 momentum : 1.93
Left Arm D1 NMR : 0.714183
Left Arm Q3 power supply current : 768.375
Left Arm Q3 momentum : 1.93001
Left Arm Q3 gauss meter : 0.3837
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 72.6749
Current on Unser monitor : 80.387
Current on Upstream bcm : 72.4922
Current on Downstream bcm : 72.8575
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 130.648
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.151404
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.2
haSC200_6_Sensor_2_R : 26.46
haSC200_6_Sensor_3_R : 42.56
haSC200_6_Sensor_4_R : 41.81
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.32
haITC502_1_Sensor_3_R : 80.63
haITC502_4_Sensor_1_R : 87.1
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 312.69
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.35
haITC502_6_Sensor_2_R : 85.04
haITC502_6_Sensor_3_R : 28.79
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -1246
HacR_VPM_LVDT:VALr : -69
HacR_HPE1313A:0_Ch58 : -0.539062
HacR_HPE1313A:0_Ch55 : 22.9492
HacR_HPE1313A:0_Ch54 : -0.741211
HacR_alignROLL : -0.260231
HacR_alignPITCH : -0.0170594
HacR_alignHPT : -1.46371
HacL_HPM_LVDT:VALr : -6938
HacL_VPM_LVDT:VALr : 1358
HacL_HPE1313A:0_Ch58 : -0.225098
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : 0.0776367
HacL_alignROLL : 0.415836
HacL_alignPITCH : -0.0644389
HacL_alignHPT : 3.82072
Right Arm Angle Floor Angle : 29.5
Right Arm Angle Vernier : 40.4
Right Arm Scattering Angle : 29.9398
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -54
Left Arm Scattering Angle : 12.4839
Wien angle : 43.1664
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 964.77
Wien field : 28.089
Laser attenuation Hall A : 309
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88