Log entry time 03:50:24 on April 13, 2001
Entry number 60310
keyword=Start_Run_3494_RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin30,
Beginning-of-run EPICS data for Run Number 3494 at Fri Apr 13 03:49:07 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=900,ps2=5000,ps3=60000,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1240.65
Right Arm Q1 momentum : 1.64994
Right Arm Q1 gauss meter : -0.0309
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 709.958
Right Arm Q2 momentum : 1.64966
Right Arm Q2 gauss meter : 0.3731
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 567.572
Right Arm D1 momentum : 1.65
Right Arm D1 NMR : 0.612295
Right Arm Q3 power supply current : 656.391
Right Arm Q3 momentum : 1.6496
Right Arm Q3 gauss meter : 0.2944
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1451.94
Left Arm Q1 momentum : 1.92992
Left Arm Q1 gauss meter : 0.12337
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 830.98
Left Arm Q2 momentum : 1.92982
Left Arm Q2 gauss meter : -0.4379
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 653.828
Left Arm D1 momentum : 1.93
Left Arm D1 NMR : 0.714183
Left Arm Q3 power supply current : 768.342
Left Arm Q3 momentum : 1.92997
Left Arm Q3 gauss meter : 0.3837
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 43.5494
Current on Unser monitor : 50.3809
Current on Upstream bcm : 43.4969
Current on Downstream bcm : 43.6019
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 43.7423
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.03541
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.25
haSC200_6_Sensor_2_R : 26.46
haSC200_6_Sensor_3_R : 42.62
haSC200_6_Sensor_4_R : 41.82
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.38
haITC502_1_Sensor_3_R : 80.51
haITC502_4_Sensor_1_R : 87.2
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 26.7
haITC502_5_Sensor_2_R : 312.97
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.43
haITC502_6_Sensor_2_R : 85.12
haITC502_6_Sensor_3_R : 28.79
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -1245
HacR_VPM_LVDT:VALr : -61
HacR_HPE1313A:0_Ch58 : -0.538574
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.741211
HacR_alignROLL : -0.259245
HacR_alignPITCH : -0.0175084
HacR_alignHPT : -1.46539
HacL_HPM_LVDT:VALr : -6937
HacL_VPM_LVDT:VALr : 1364
HacL_HPE1313A:0_Ch58 : -0.225098
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : 0.0776367
HacL_alignROLL : 0.416301
HacL_alignPITCH : -0.0644389
HacL_alignHPT : 3.81826
Right Arm Angle Floor Angle : 29.5
Right Arm Angle Vernier : 40.4
Right Arm Scattering Angle : 29.9398
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -54
Left Arm Scattering Angle : 12.4839
Wien angle : 43.1664
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 964.77
Wien field : 28.089
Laser attenuation Hall A : 217
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA :
Survey Y offset bpmA :
Survey X offset bpmB :
Survey Y offset bpmB :