User name adev
Log entry time 04:40:32 on April 13, 2001
Entry number 60315
keyword=Start_Run_3497_RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin30,
Beginning-of-run EPICS data for Run Number 3497 at Fri Apr 13 04:39:31 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=900,ps2=5000,ps3=60000,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1240.71
Right Arm Q1 momentum : 1.65003
Right Arm Q1 gauss meter : -0.0309
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 709.984
Right Arm Q2 momentum : 1.64972
Right Arm Q2 gauss meter : 0.3732
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 567.572
Right Arm D1 momentum : 1.65
Right Arm D1 NMR : 0.612295
Right Arm Q3 power supply current : 656.559
Right Arm Q3 momentum : 1.65002
Right Arm Q3 gauss meter : 0.2946
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1451.87
Left Arm Q1 momentum : 1.92983
Left Arm Q1 gauss meter : 0.1234
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 831.236
Left Arm Q2 momentum : 1.93041
Left Arm Q2 gauss meter : -0.438
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 653.827
Left Arm D1 momentum : 1.93
Left Arm D1 NMR : 0.714181
Left Arm Q3 power supply current : 768.324
Left Arm Q3 momentum : 1.92989
Left Arm Q3 gauss meter : 0.3837
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 33.793
Current on Unser monitor : 41.8506
Current on Upstream bcm : 33.7871
Current on Downstream bcm : 33.7989
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 34.1234
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 69
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.21
haSC200_6_Sensor_2_R : 26.46
haSC200_6_Sensor_3_R : 42.61
haSC200_6_Sensor_4_R : 41.81
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.39
haITC502_1_Sensor_3_R : 80.68
haITC502_4_Sensor_1_R : 87.2
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 95.58
haITC502_5_Sensor_2_R : 93.38
haITC502_5_Sensor_3_R : 266.9
haITC502_6_Sensor_1_R : 99.45
haITC502_6_Sensor_2_R : 85.09
haITC502_6_Sensor_3_R : 28.78
Right Arm Arm Collimator : 0.615234
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -1246
HacR_VPM_LVDT:VALr : -59
HacR_HPE1313A:0_Ch58 : -0.540039
HacR_HPE1313A:0_Ch55 : 22.9004
HacR_HPE1313A:0_Ch54 : -0.742188
HacR_alignROLL : -0.259245
HacR_alignPITCH : -0.0166104
HacR_alignHPT : -1.46428
HacL_HPM_LVDT:VALr : -6935
HacL_VPM_LVDT:VALr : 1370
HacL_HPE1313A:0_Ch58 : -0.224609
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : 0.078125
HacL_alignROLL : 0.415836
HacL_alignPITCH : -0.0644389
HacL_alignHPT : 3.81401
Right Arm Angle Floor Angle : 29.5
Right Arm Angle Vernier : 40.4
Right Arm Scattering Angle : 29.9398
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -54
Left Arm Scattering Angle : 12.4839
Wien angle : 43.1664
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 964.77
Wien field : 28.089
Laser attenuation Hall A : 194
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA :
Survey Y offset bpmA :
Survey X offset bpmB :
Survey Y offset bpmB :