User name adev
Log entry time 10:25:46 on April 13, 2001
Entry number 60346
keyword=Start_Run_3509_RunType=Other,Tar=dum-15cm,Rad=out,comment=kin
Beginning-of-run EPICS data for Run Number 3509 at Fri Apr 13 10:25:37 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=85,ps2=1000,ps3=2000,ps4=1200,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1240.65
Right Arm Q1 momentum : 1.64994
Right Arm Q1 gauss meter : -0.0309
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 710.069
Right Arm Q2 momentum : 1.64991
Right Arm Q2 gauss meter : 0.3732
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 567.573
Right Arm D1 momentum : 1.65
Right Arm D1 NMR : 0.612295
Right Arm Q3 power supply current : 656.403
Right Arm Q3 momentum : 1.64963
Right Arm Q3 gauss meter : 0.2945
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1494.01
Left Arm Q1 momentum : 1.98584
Left Arm Q1 gauss meter : 0.12691
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 854.993
Left Arm Q2 momentum : 1.98558
Left Arm Q2 gauss meter : -0.4506
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 674.123
Left Arm D1 momentum : 1.986
Left Arm D1 NMR : 0.734893
Left Arm Q3 power supply current : 790.651
Left Arm Q3 momentum : 1.98597
Left Arm Q3 gauss meter : 0.3949
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 29.0012
Current on Unser monitor : 37.2659
Current on Upstream bcm : 28.9121
Current on Downstream bcm : 29.0902
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 93.9111
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.163614
haBDSPOS : 1.70075e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.16
haSC200_6_Sensor_2_R : 26.46
haSC200_6_Sensor_3_R : 42.62
haSC200_6_Sensor_4_R : 41.81
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 80.73
haITC502_4_Sensor_1_R : 87.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 39.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 85.55
haITC502_6_Sensor_3_R : 28.76
Right Arm Arm Collimator : 0.615234
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -773
HacR_VPM_LVDT:VALr : 36
HacR_HPE1313A:0_Ch58 : -0.538086
HacR_HPE1313A:0_Ch55 : 23.0469
HacR_HPE1313A:0_Ch54 : -0.755371
HacR_alignROLL : -0.273484
HacR_alignPITCH : -0.0175748
HacR_alignHPT : -1.98562
HacL_HPM_LVDT:VALr : -7619
HacL_VPM_LVDT:VALr : 2210
HacL_HPE1313A:0_Ch58 : -0.142578
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.0292969
HacL_alignROLL : 0.313578
HacL_alignPITCH : -0.138237
HacL_alignHPT : 4.63296
Right Arm Angle Floor Angle : 30
Right Arm Angle Vernier : -46.3
Right Arm Scattering Angle : 29.9436
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 5
Left Arm Scattering Angle : 16.8184
Wien angle : 43.1664
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 964.77
Wien field : 28.089
Laser attenuation Hall A : 202
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88