Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 11:47:11 on April 13, 2001
Entry number 60354
keyword=End_of_Run_3511
****************************
Run Number: 3511
End of Run Comment:
RunType=Other,Tar=dum-15cm,Rad=out,comment=kin 27 x=2.103,mode=singles,Lmom=1.986,Rmom=-1.650,Ene=4.232,Angle_R=29.94,Angle_L=16.82
Time of run = 38.178288 min
Av. current (on 3x) = 28.552878 uA
Av. current (on 1x) = 28.448805 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 65.1676 | 65.4060 | 65.5246
up-down (mC)| -0.5219 | -0.2855 | -0.1975
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 845.30898 Hz | 29605.0 /mC | 105.664 Hz | 1936347 | 8 | 29713.3 /mC
2 | 9804.0169 Hz | 343363.5 /mC | 98.040 Hz | 22458035 | 100 | 344619.6 /mC
3 | 21047.825 Hz | 737152.5 /mC | 140.319 Hz | 48214195 | 150 | 739849.2 /mC
4 | 12393.987 Hz | 434071.4 /mC | 103.283 Hz | 28390873 | 120 | 435659.3 /mC
5 | 12.237322 Hz | 428.6 /mC | 12.237 Hz | 28032 | 1 | 430.2 /mC
Trigger 5 corrected for pulser:
5 (phys) | 2.063127 Hz | 72.3 /mC | 2.063 Hz | 4725.999 | 1 | 72.5 /mC
8 | 1024.0 Hz | 35863.3 /mC | 0.016 Hz | 2345674 | 65535 | 35994.5 /mC
output 436.736 Hz
Av. deadtime from accepted triggers = 0.0463
Av. deadtime from gated scalers = 0.0599
Accepted triggers = 1000431.00000
Rate of Left Arm Pulser for electronic DT = 10.174195
Rate of Right Arm Pulser for electronic DT = 10.196459
Rate of Left Arm Pulser&trig for electronic DT = 10.162408
Rate of Right Arm Pulser&trig for electronic DT = 10.196459
Left Arm Electronic DT = 0.0011585
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 45441.631
Rate of Right Arm Strobe = 11174.007
Signal | Charge (C)
upstream | 0.0649066
upstream 3x | 0.0652633
upstream 10x| 0.0654258
downstream | 0.0654285
downstream 3x | 0.0655488
downstream 10x| 0.0656233
****************************
End-of-run EPICS data for Run Number 3511 at Fri Apr 13 11:47:00 EDT 2001
Right Arm D1 momentum : 1.65
Right Arm arm angle : 29.9436
Left Arm D1 momentum : 1.98601
Left Arm arm angle : 16.8184
Tiefenbach Hall A energy : 4236.97
Right Arm arm mispointing (HPT) : -1.98643
Left Arm arm mispointing (HPT) : 4.63277
Right Arm Q1 power supply current : 1240.65
Right Arm Q1 momentum : 1.64994
Right Arm Q1 gauss meter : -0.0309
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 709.94
Right Arm Q2 momentum : 1.64961
Right Arm Q2 gauss meter : 0.3732
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 567.571
Right Arm D1 momentum : 1.65
Right Arm D1 NMR : 0.612295
Right Arm Q3 power supply current : 656.72
Right Arm Q3 momentum : 1.65043
Right Arm Q3 gauss meter : 0.2945
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1494.01
Left Arm Q1 momentum : 1.98584
Left Arm Q1 gauss meter : 0.12693
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 855.092
Left Arm Q2 momentum : 1.98582
Left Arm Q2 gauss meter : -0.4506
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 674.123
Left Arm D1 momentum : 1.986
Left Arm D1 NMR : 0.734894
Left Arm Q3 power supply current : 790.599
Left Arm Q3 momentum : 1.98584
Left Arm Q3 gauss meter : 0.3949
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 27.9649
Current on Unser monitor : 35.5707
Current on Upstream bcm : 27.9356
Current on Downstream bcm : 27.9942
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 89.3135
MBSY1c Hall A Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
MBSY1c Bdl : 1.05954e+06
MBSY3c Hall C Beam energy : 3408.77
Tiefenbach Hall A energy : 4236.97
Tiefenbach Hall C energy : 3399.64
Delta(E)/E width (MV_AI_DXWID) : 1.05156
IPM1C12.XPOS : 0.00214714
IPM1H04A.XPOS : 3.16753
IPM1H04A.YPOS : 0.122848
IPM1H04B.XPOS : 2.12843
IPM1H04B.YPOS : -0.0242407
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -773
HacR_VPM_LVDT:VALr : 37
HacR_HPE1313A:0_Ch58 : -0.538574
HacR_HPE1313A:0_Ch55 : 22.9492
HacR_HPE1313A:0_Ch54 : -0.754395
HacR_alignROLL : -0.272557
HacR_alignPITCH : -0.0175084
HacR_alignHPT : -1.98615
HacL_HPM_LVDT:VALr : -7621
HacL_VPM_LVDT:VALr : 2206
HacL_HPE1313A:0_Ch58 : -0.142578
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.0292969
HacL_alignROLL : 0.313578
HacL_alignPITCH : -0.137364
HacL_alignHPT : 4.63407
haBDSPOS : 1.70075e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65.5
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 20.59
haH2_P_Exhaust_R : 20.94
haH2_P_Fill_Bottle_R : 20.6
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.75
haD2_P_Fill_Bottle_R : 38.8
haD2_DP_Fill_Exhaust_R : 0.0746
haSC200_6_Sensor_1_R : 242.11
haSC200_6_Sensor_2_R : 26.5
haSC200_6_Sensor_3_R : 42.61
haSC200_6_Sensor_4_R : 41.74
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 81.05
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 18.99
haITC502_4_Sensor_1_R : 87.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 3.99
haITC502_5_Sensor_3_R : 10
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 85.65
haITC502_6_Sensor_3_R : 28.77
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.61709
Wien angle : 43.1664
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 964.77
Wien field : 28.089
Laser attenuation Hall A : 198
Laser power Hall A : 57
Half-wave plate (off=out) : ON