User name adev
Log entry time 11:47:41 on April 13, 2001
Entry number 60355
keyword=Start_Run_3512_RunType=Other,Tar=dum-15cm,Rad=out,comment=kin
Beginning-of-run EPICS data for Run Number 3512 at Fri Apr 13 11:47:27 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=8,ps2=100,ps3=150,ps4=120,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1240.65
Right Arm Q1 momentum : 1.64994
Right Arm Q1 gauss meter : -0.03091
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 709.866
Right Arm Q2 momentum : 1.64944
Right Arm Q2 gauss meter : 0.3731
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 567.574
Right Arm D1 momentum : 1.65
Right Arm D1 NMR : 0.612295
Right Arm Q3 power supply current : 656.587
Right Arm Q3 momentum : 1.6501
Right Arm Q3 gauss meter : 0.2945
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1494.08
Left Arm Q1 momentum : 1.98593
Left Arm Q1 gauss meter : 0.12693
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 855.049
Left Arm Q2 momentum : 1.98572
Left Arm Q2 gauss meter : -0.4507
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 674.124
Left Arm D1 momentum : 1.98601
Left Arm D1 NMR : 0.734894
Left Arm Q3 power supply current : 790.719
Left Arm Q3 momentum : 1.98614
Left Arm Q3 gauss meter : 0.3949
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 28.8172
Current on Unser monitor : 37.1587
Current on Upstream bcm : 28.7871
Current on Downstream bcm : 28.8473
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 93.8344
Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.163614
haBDSPOS : 1.70075e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 242.11
haSC200_6_Sensor_2_R : 26.51
haSC200_6_Sensor_3_R : 42.61
haSC200_6_Sensor_4_R : 41.77
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 81.06
haITC502_4_Sensor_1_R : 87.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 3.99
haITC502_5_Sensor_2_R : 1
haITC502_5_Sensor_3_R : 0.6
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 85.68
haITC502_6_Sensor_3_R : 28.76
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -773
HacR_VPM_LVDT:VALr : 36
HacR_HPE1313A:0_Ch58 : -0.539551
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.754395
HacR_alignROLL : -0.272557
HacR_alignPITCH : -0.0166104
HacR_alignHPT : -1.98615
HacL_HPM_LVDT:VALr : -7624
HacL_VPM_LVDT:VALr : 2206
HacL_HPE1313A:0_Ch58 : -0.143066
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.0297852
HacL_alignROLL : 0.313578
HacL_alignPITCH : -0.137364
HacL_alignHPT : 4.63184
Right Arm Angle Floor Angle : 30
Right Arm Angle Vernier : -46.3
Right Arm Scattering Angle : 29.9436
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 5
Left Arm Scattering Angle : 16.8184
Wien angle : 43.1664
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 964.77
Wien field : 28.089
Laser attenuation Hall A : 202
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88