User name adev
Log entry time 22:08:45 on April 13, 2001
Entry number 60385
keyword=Start_Run_3523_RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin
Beginning-of-run EPICS data for Run Number 3523 at Fri Apr 13 22:08:32 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1800,ps2=1000,ps3=1800,ps4=600,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 781.97
Right Arm Q1 momentum : 1.03994
Right Arm Q1 gauss meter : -0.019567
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 447.494
Right Arm Q2 momentum : 1.03979
Right Arm Q2 gauss meter : 0.2353
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 355.001
Right Arm D1 momentum : 1.04
Right Arm D1 NMR : 0.385931
Right Arm Q3 power supply current : 414.059
Right Arm Q3 momentum : 1.04059
Right Arm Q3 gauss meter : 0.18546
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 467.18
Left Arm Q1 momentum : 0.620976
Left Arm Q1 gauss meter : 0.04027
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 267.579
Left Arm Q2 momentum : 0.62141
Left Arm Q2 gauss meter : -0.14147
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 206.723
Left Arm D1 momentum : 0.620993
Left Arm D1 NMR : 0.230005
Left Arm Q3 power supply current : 247.226
Left Arm Q3 momentum : 0.620987
Left Arm Q3 gauss meter : 0.12434
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 48.2447
Current on Unser monitor : 55.8189
Current on Upstream bcm : 48.2011
Current on Downstream bcm : 48.2882
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 48.6421
Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.161172
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.2
haSC200_6_Sensor_2_R : 26.55
haSC200_6_Sensor_3_R : 42.67
haSC200_6_Sensor_4_R : 41.77
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 80.78
haITC502_4_Sensor_1_R : 87.7
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 94.26
haITC502_5_Sensor_2_R : 26.67
haITC502_5_Sensor_3_R : 3161.2
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 85.83
haITC502_6_Sensor_3_R : 28.77
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -956
HacR_VPM_LVDT:VALr : 60
HacR_HPE1313A:0_Ch58 : -0.520996
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.819824
HacR_alignROLL : -0.339121
HacR_alignPITCH : -0.033671
HacR_alignHPT : -1.71796
HacL_HPM_LVDT:VALr : -8462
HacL_VPM_LVDT:VALr : -471
HacL_HPE1313A:0_Ch58 : -0.235352
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.251953
HacL_alignROLL : 0.110103
HacL_alignPITCH : -0.034789
HacL_alignHPT : 5.6692
Right Arm Angle Floor Angle : 19
Right Arm Angle Vernier : -33.9
Right Arm Scattering Angle : 19.0133
Left Arm Angle Floor Angle : 41.5
Left Arm Angle Vernier : 48.5
Left Arm Scattering Angle : 41.5621
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 229
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88