User name adev
Log entry time 23:06:36 on April 13, 2001
Entry number 60389
keyword=End_of_Run_3525
****************************
Run Number: 3525
End of Run Comment:
RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin 50 ,mode=coincidence,Lmom=0.621,Rmom=-1.040,Ene=1.721,Angle_R=19.013,Angle_L=41.562
Time of run = 16.029134 min
Av. current (on 3x) = 48.33844 uA
Av. current (on 1x) = 48.189752 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 46.3464 | 46.4894 | 46.5246
up-down (mC)| -0.3751 | -0.1495 | -0.1274
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 113615.51 Hz | 2350417.3 /mC | 63.120 Hz | 109269490 | 1800 | 2357669.4 /mC
2 | 50567.333 Hz | 1046110.2 /mC | 50.567 Hz | 48633034 | 1000 | 1049337.9 /mC
3 | 92773.023 Hz | 1919239.1 /mC | 51.541 Hz | 89224274 | 1800 | 1925160.8 /mC
4 | 35818.453 Hz | 740993.2 /mC | 59.697 Hz | 34448327 | 600 | 743279.5 /mC
5 | 1003.1754 Hz | 20753.2 /mC | 1003.175 Hz | 964802 | 1 | 20817.2 /mC
Trigger 5 corrected for pulser:
5 (phys) | 993.00226 Hz | 20542.7 /mC | 993.002 Hz | 955018.0 | 1 | 20606.1 /mC
8 | 1024.0 Hz | 21184.0 /mC | 0.016 Hz | 984830 | 65535 | 21249.3 /mC
output 1045.238 Hz
Av. deadtime from accepted triggers = 0.1481
Av. deadtime from gated scalers = 0.1482
Accepted triggers = 1005256.00000
Rate of Left Arm Pulser for electronic DT = 10.173143
Rate of Right Arm Pulser for electronic DT = 10.189779
Rate of Left Arm Pulser&trig for electronic DT = 10.118035
Rate of Right Arm Pulser&trig for electronic DT = 10.18562
Left Arm Electronic DT = 0.0054170074
Right Arm Electronic DT = 0.00040816327
Rate of Left Strobe = 195165.83
Rate of Right Arm Strobe = 202333.17
Signal | Charge (C)
upstream | 0.0461589
upstream 3x | 0.0464146
upstream 10x| 0.0464609
downstream | 0.0465340
downstream 3x | 0.0465641
downstream 10x| 0.0465883
****************************
End-of-run EPICS data for Run Number 3525 at Fri Apr 13 23:06:23 EDT 2001
Right Arm D1 momentum : 1.04
Right Arm arm angle : 19.0133
Left Arm D1 momentum : 0.62099
Left Arm arm angle : 41.5622
Tiefenbach Hall A energy : 1722.7
Right Arm arm mispointing (HPT) : -1.71905
Left Arm arm mispointing (HPT) : 5.66567
Right Arm Q1 power supply current : 781.97
Right Arm Q1 momentum : 1.03994
Right Arm Q1 gauss meter : -0.019557
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 447.427
Right Arm Q2 momentum : 1.03964
Right Arm Q2 gauss meter : 0.2352
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 355
Right Arm D1 momentum : 1.04
Right Arm D1 NMR : 0.385931
Right Arm Q3 power supply current : 413.978
Right Arm Q3 momentum : 1.04038
Right Arm Q3 gauss meter : 0.18544
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 467.18
Left Arm Q1 momentum : 0.620976
Left Arm Q1 gauss meter : 0.04028
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 267.204
Left Arm Q2 momentum : 0.620538
Left Arm Q2 gauss meter : -0.14147
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 206.724
Left Arm D1 momentum : 0.62099
Left Arm D1 NMR : 0.230004
Left Arm Q3 power supply current : 247.352
Left Arm Q3 momentum : 0.621303
Left Arm Q3 gauss meter : 0.12434
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 48.134
Current on Unser monitor : 55.9658
Current on Upstream bcm : 48.0949
Current on Downstream bcm : 48.173
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 48.6079
MBSY1c Hall A Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
MBSY1c Bdl : 430337
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 1722.7
Tiefenbach Hall C energy : 883.905
Delta(E)/E width (MV_AI_DXWID) : 0.203983
IPM1C12.XPOS : -0.00448605
IPM1H04A.XPOS : 0.742975
IPM1H04A.YPOS : 0.813247
IPM1H04B.XPOS : -0.0471984
IPM1H04B.YPOS : -0.0148364
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -955
HacR_VPM_LVDT:VALr : 58
HacR_HPE1313A:0_Ch58 : -0.521973
HacR_HPE1313A:0_Ch55 : 22.9492
HacR_HPE1313A:0_Ch54 : -0.820312
HacR_alignROLL : -0.339121
HacR_alignPITCH : -0.033671
HacR_alignHPT : -1.71908
HacL_HPM_LVDT:VALr : -8459
HacL_VPM_LVDT:VALr : -475
HacL_HPE1313A:0_Ch58 : -0.234863
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.251465
HacL_alignROLL : 0.110474
HacL_alignPITCH : -0.0351535
HacL_alignHPT : 5.66679
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 20.34
haH2_P_Exhaust_R : 20.66
haH2_P_Fill_Bottle_R : 20.37
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.54
haD2_P_Fill_Bottle_R : 38.34
haD2_DP_Fill_Exhaust_R : 0.0745
haSC200_6_Sensor_1_R : 242.16
haSC200_6_Sensor_2_R : 26.53
haSC200_6_Sensor_3_R : 42.66
haSC200_6_Sensor_4_R : 41.77
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 80.89
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 18.99
haITC502_2_Sensor_3_R : 19.11
haITC502_4_Sensor_1_R : 87.8
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 96.43
haITC502_5_Sensor_2_R : 94.16
haITC502_5_Sensor_3_R : 266.7
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 85.88
haITC502_6_Sensor_3_R : 28.76
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.617041
Wien angle : 0
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 230
Laser power Hall A : 57
Half-wave plate (off=out) : ON