User name adev
Log entry time 00:49:51 on April 14, 2001
Entry number 60406
keyword=Start_Run_3532_RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin51
Beginning-of-run EPICS data for Run Number 3532 at Sat Apr 14 00:49:38 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10000,ps2=5000,ps3=10000,ps4=4000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 782.005
Right Arm Q1 momentum : 1.03999
Right Arm Q1 gauss meter : -0.019566
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 447.698
Right Arm Q2 momentum : 1.04027
Right Arm Q2 gauss meter : 0.2352
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 355.001
Right Arm D1 momentum : 1.04
Right Arm D1 NMR : 0.385931
Right Arm Q3 power supply current : 413.689
Right Arm Q3 momentum : 1.03966
Right Arm Q3 gauss meter : 0.18541
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 396.2
Left Arm Q1 momentum : 0.52663
Left Arm Q1 gauss meter : 0.03426
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 226.931
Left Arm Q2 momentum : 0.527011
Left Arm Q2 gauss meter : -0.12009
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 175.111
Left Arm D1 momentum : 0.526694
Left Arm D1 NMR : 0.195117
Left Arm Q3 power supply current : 209.704
Left Arm Q3 momentum : 0.526737
Left Arm Q3 gauss meter : 0.10564
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 48.0522
Current on Unser monitor : 54.3553
Current on Upstream bcm : 47.9831
Current on Downstream bcm : 48.2789
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 48.5134
Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 71.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.15
haSC200_6_Sensor_2_R : 26.51
haSC200_6_Sensor_3_R : 42.69
haSC200_6_Sensor_4_R : 41.76
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.95
haITC502_1_Sensor_3_R : 80.96
haITC502_4_Sensor_1_R : 87.5
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 96.2
haITC502_5_Sensor_2_R : 93.96
haITC502_5_Sensor_3_R : 266.7
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 85.6
haITC502_6_Sensor_3_R : 28.78
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -951
HacR_VPM_LVDT:VALr : 62
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.819824
HacR_alignROLL : -0.337642
HacR_alignPITCH : -0.033671
HacR_alignHPT : -1.7244
HacL_HPM_LVDT:VALr : -8455
HacL_VPM_LVDT:VALr : -473
HacL_HPE1313A:0_Ch58 : -0.234375
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.250488
HacL_alignROLL : 0.111357
HacL_alignPITCH : -0.0355902
HacL_alignHPT : 5.66078
Right Arm Angle Floor Angle : 19
Right Arm Angle Vernier : -33.9
Right Arm Scattering Angle : 19.0133
Left Arm Angle Floor Angle : 41.5
Left Arm Angle Vernier : 48.5
Left Arm Scattering Angle : 41.5622
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 230
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88