User name adev
Log entry time 03:05:53 on April 14, 2001
Entry number 60422
keyword=End_of_Run_3539
****************************
Run Number: 3539
End of Run Comment:
RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin51 ,mode=coincidence,Lmom=0.5267,Rmom=-1.040,Ene=1.721,Angle_R=19.013,Angle_L=41.562
Time of run = 15.705811 min
Av. current (on 3x) = 48.408199 uA
Av. current (on 1x) = 48.258891 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 45.4767 | 45.6174 | 45.6511
up-down (mC)| -0.3676 | -0.1489 | -0.1248
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 113829.87 Hz | 2351458.4 /mC | 11.383 Hz | 107267420 | 10000 | 2358733.6 /mC
2 | 51201.835 Hz | 1057710.0 /mC | 10.240 Hz | 48249979 | 5000 | 1060982.4 /mC
3 | 112274.5 Hz | 2319328.2 /mC | 11.227 Hz | 105801720 | 10000 | 2326503.9 /mC
4 | 42904.582 Hz | 886308.2 /mC | 10.726 Hz | 40431074 | 4000 | 889050.3 /mC
5 | 1211.8477 Hz | 25033.9 /mC | 1211.848 Hz | 1141983 | 1 | 25111.4 /mC
Trigger 5 corrected for pulser:
5 (phys) | 1201.6774 Hz | 24823.8 /mC | 1201.677 Hz | 1132399.0 | 1 | 24900.6 /mC
8 | 1024.0 Hz | 21153.4 /mC | 0.016 Hz | 964965 | 65535 | 21218.9 /mC
output 1062.976 Hz
Av. deadtime from accepted triggers = 0.1531
Av. deadtime from gated scalers = 0.1517
Accepted triggers = 1001694.00000
Rate of Left Arm Pulser for electronic DT = 10.170334
Rate of Right Arm Pulser for electronic DT = 10.188374
Rate of Left Arm Pulser&trig for electronic DT = 10.096051
Rate of Right Arm Pulser&trig for electronic DT = 10.186251
Left Arm Electronic DT = 0.0073038397
Right Arm Electronic DT = 0.00020831163
Rate of Left Strobe = 243899.63
Rate of Right Arm Strobe = 204675.59
Signal | Charge (C)
upstream | 0.0452929
upstream 3x | 0.0455430
upstream 10x| 0.0455887
downstream | 0.0456605
downstream 3x | 0.0456919
downstream 10x| 0.0457135
****************************
End-of-run EPICS data for Run Number 3539 at Sat Apr 14 03:05:41 EDT 2001
Right Arm D1 momentum : 1.04
Right Arm arm angle : 19.0133
Left Arm D1 momentum : 0.526689
Left Arm arm angle : 41.5622
Tiefenbach Hall A energy : 1722.69
Right Arm arm mispointing (HPT) : -1.73217
Left Arm arm mispointing (HPT) : 5.65718
Right Arm Q1 power supply current : 782.075
Right Arm Q1 momentum : 1.04008
Right Arm Q1 gauss meter : -0.019558
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 447.625
Right Arm Q2 momentum : 1.0401
Right Arm Q2 gauss meter : 0.2353
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 355.001
Right Arm D1 momentum : 1.04
Right Arm D1 NMR : 0.385931
Right Arm Q3 power supply current : 413.898
Right Arm Q3 momentum : 1.04018
Right Arm Q3 gauss meter : 0.18545
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 396.27
Left Arm Q1 momentum : 0.526723
Left Arm Q1 gauss meter : 0.03427
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 226.938
Left Arm Q2 momentum : 0.527028
Left Arm Q2 gauss meter : -0.12018
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 175.111
Left Arm D1 momentum : 0.52669
Left Arm D1 NMR : 0.195115
Left Arm Q3 power supply current : 209.694
Left Arm Q3 momentum : 0.526711
Left Arm Q3 gauss meter : 0.1056
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 48.2793
Current on Unser monitor : 55.648
Current on Upstream bcm : 48.2426
Current on Downstream bcm : 48.316
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 48.6695
MBSY1c Hall A Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
MBSY1c Bdl : 430337
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 1722.69
Tiefenbach Hall C energy : 883.905
Delta(E)/E width (MV_AI_DXWID) : 0.203983
IPM1C12.XPOS : 0.0100259
IPM1H04A.XPOS : 0.750075
IPM1H04A.YPOS : 0.817798
IPM1H04B.XPOS : -0.0401979
IPM1H04B.YPOS : -0.00894092
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -943
HacR_VPM_LVDT:VALr : 69
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 22.9004
HacR_HPE1313A:0_Ch54 : -0.818848
HacR_alignROLL : -0.337642
HacR_alignPITCH : -0.033671
HacR_alignHPT : -1.73336
HacL_HPM_LVDT:VALr : -8449
HacL_VPM_LVDT:VALr : -469
HacL_HPE1313A:0_Ch58 : -0.234863
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.25
HacL_alignROLL : 0.111799
HacL_alignPITCH : -0.0355902
HacL_alignHPT : 5.65498
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65.5
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 20.31
haH2_P_Exhaust_R : 20.63
haH2_P_Fill_Bottle_R : 20.3
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.52
haD2_P_Fill_Bottle_R : 38.25
haD2_DP_Fill_Exhaust_R : 0.0746
haSC200_6_Sensor_1_R : 242.13
haSC200_6_Sensor_2_R : 26.46
haSC200_6_Sensor_3_R : 42.67
haSC200_6_Sensor_4_R : 41.74
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.66
haITC502_1_Sensor_3_R : 80.55
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.12
haITC502_4_Sensor_1_R : 87.3
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 95.93
haITC502_5_Sensor_2_R : 93.68
haITC502_5_Sensor_3_R : 266.6
haITC502_6_Sensor_1_R : 99.95
haITC502_6_Sensor_2_R : 85.47
haITC502_6_Sensor_3_R : 28.77
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.617041
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 230
Laser power Hall A : 57
Half-wave plate (off=out) : ON