Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 03:59:10 on April 14, 2001
Entry number 60429
keyword=Start_Run_3543_RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin51
Beginning-of-run EPICS data for Run Number 3543 at Sat Apr 14 03:58:57 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10000,ps2=5000,ps3=10000,ps4=4000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 781.97
Right Arm Q1 momentum : 1.03994
Right Arm Q1 gauss meter : -0.019573
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 447.802
Right Arm Q2 momentum : 1.04051
Right Arm Q2 gauss meter : 0.2353
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 354.993
Right Arm D1 momentum : 1.04
Right Arm D1 NMR : 0.38593
Right Arm Q3 power supply current : 413.953
Right Arm Q3 momentum : 1.04032
Right Arm Q3 gauss meter : 0.18542
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 396.27
Left Arm Q1 momentum : 0.526723
Left Arm Q1 gauss meter : 0.03425
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 226.935
Left Arm Q2 momentum : 0.52702
Left Arm Q2 gauss meter : -0.12015
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 175.11
Left Arm D1 momentum : 0.526692
Left Arm D1 NMR : 0.195116
Left Arm Q3 power supply current : 209.622
Left Arm Q3 momentum : 0.526532
Left Arm Q3 gauss meter : 0.10558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 48.4372
Current on Unser monitor : 55.7121
Current on Upstream bcm : 48.3872
Current on Downstream bcm : 48.3969
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 96.4755
Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 67.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.16
haSC200_6_Sensor_2_R : 26.53
haSC200_6_Sensor_3_R : 42.67
haSC200_6_Sensor_4_R : 41.77
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.59
haITC502_1_Sensor_3_R : 80.6
haITC502_4_Sensor_1_R : 87.3
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 26.66
haITC502_5_Sensor_3_R : 3140.7
haITC502_6_Sensor_1_R : 99.9
haITC502_6_Sensor_2_R : 85.31
haITC502_6_Sensor_3_R : 28.77
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -944
HacR_VPM_LVDT:VALr : 72
HacR_HPE1313A:0_Ch58 : -0.520996
HacR_HPE1313A:0_Ch55 : 22.9492
HacR_HPE1313A:0_Ch54 : -0.818359
HacR_alignROLL : -0.337207
HacR_alignPITCH : -0.0336042
HacR_alignHPT : -1.73249
HacL_HPM_LVDT:VALr : -8452
HacL_VPM_LVDT:VALr : -465
HacL_HPE1313A:0_Ch58 : -0.234863
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.25
HacL_alignROLL : 0.112241
HacL_alignPITCH : -0.0351535
HacL_alignHPT : 5.65812
Right Arm Angle Floor Angle : 19
Right Arm Angle Vernier : -33.9
Right Arm Scattering Angle : 19.0133
Left Arm Angle Floor Angle : 41.5
Left Arm Angle Vernier : 48.5
Left Arm Scattering Angle : 41.5622
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 246
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88